Keys to Successful Analysis - Borate Fusion of Sand & Aluminosilicates

Log in to watch this webinar

Not registered yet? Criar uma conta
00:00:00 Keys to Successful Analysis - Borate Fusion of Sand & Aluminosilicates
00:00:17 Introduction
00:02:15 Overview
00:02:49 Sand & Aluminosilicates
00:04:49 Sand & Aluminosilicates
00:06:37 Purpose of the Project
00:07:09 Fusion Method and Instrumentation
00:07:17 Sand & Aluminosilicates
00:08:08 Sand & Aluminosilicates
00:10:26 Sand & Aluminosilicates
00:11:19 Equipment Used
00:11:55 LeNeo
00:12:44 LeDoser
00:16:00 Borate flux
00:16:28 Fusion Methodology
00:17:26 Fusion Methodology– Glass industry
00:18:05 Calibration Strategy and Selection of Control Sample
00:18:14 Calibration Strategy
00:19:27 Final Results
00:19:35 Evaluation of Performance
00:20:28 Evaluation of Performance
00:21:15 Conclusion
00:21:49 Questions and Thank You!

Sand is mostly used as a raw material in the production of many industrial products such as glass and cement, while aluminosilicates are used in the building, refractory and catalyst industry. It is important to know the exact compound concentrations of these materials so they remain within the tolerances over time,  contribute to cost savings and avoid waste. This project demonstrates that the use of borate fusion with Claisse LeDoser and LeNeo instruments are highly efficient in the preparation of sand and aluminosilicate samples for the analysis with an XRF spectrometer. You will discover that it is fast, easy and efficient. Borate fusion is an excellent alternative to other sample preparation techniques in the laboratory.

Palestrante

Gabrielle Cantin - Application Specialist in Fusion
Gabrielle obtained her bachelor’s degree in chemistry in 2013 from Université Laval. She completed her master’s degree in 2018. Her postgraduate project was to develop a non-dispersive and liquid extracting method for rare earth elements. She joined Claisse, now Malvern Panalytical, in 2015. Before that, she used to work at the university’s center of chemicals management. Gabrielle is now part of the application team and is focused on providing effective solutions for clients having issues with samples preparation by borate fusion.

Mais informações

  • Who should attend?

- Anyone in the building materials, refractory or catalyst industries as well as those with interest in fusion and X-ray Fluorescence (XRF) technologies. 


  • What will you learn? 

- Sample preparation by borate fusion is proven to achieve the highest levels of precision and accuracy in the XRF analysis of sand and aluminosilicates, thus ensuring constant quality of final products.