The petro edition of Zetium
The new element in petrochemicals
The Petro edition of the Zetium spectrometer is designed to deliver reliable and norm-compliant elemental analysis from crude oils to petrochemicals and fuels.
The Petro edition is pre-configured to deliver compliant results from day 1 with the appropriate hardware and your choice of compliance modules, which include factory pre-calibration according to ASTM and ISO international test methods.
Inclusion of the innovative ED core, makes it the only XRF spectrometer capable of satisfying both WDXRF and EDXRF test methods using a single instrument.
Inclusion of the innovative ED core not only delivers dual-compliance but can be used to detect unexpected elements in production samples with simultaneous spectrum acquisition.
Features
Design features for compliance
- The 1 kW SST-R Rh tube delivers exceptional performance for the majority of applications (upgrades to 2.4, 3 and 4 kW available)
- User-friendly software with integrated intelligence for novice and advanced users
- Small sample load port volume minimizes helium consumption
- Automatic sample recognition and vacuum-helium switching
- Liquid cup construction tools for simple sample preparation
Advanced software and unique application solutions
- The latest version of our renowned SuperQ software features a new, streamlined user interface, advanced matrix correction algorithms, such as multi-scatter fluorescence, integration of ED deconvolution and integrated intelligence with the Virtual Analyst
- Guarenteed compliance at start-up with factory pre-calibrated Compliance Modules:
- • S in mineral oil (ASTM D2622)
- • S in diesel (ASTM D2622)
- • S in gasoline (ASTM D2622)
- • additives in lubrication oils (ASTM D6443)
- Oil Trace eliminates mass/volume dependance and allows different types of petrochemicals to be measured against a single calibration, eliminating the cost of calibration samples and the time required to maintain multiple calibrations
Upgrade packages to meet every challenge
The modular design of the Zetium platform allows optimization of the Petro edition through the addition of upgrade packages that deliver tangible benefits:
- SumXcore - for reduction in analysis times and identification of unexpected elements in production samples
- Small Spot Mapping - ideal for the analysis of inorganic inclusions (catalysts, additives, etc.) for process troubleshooting
- Speed & throughput - for faster sample analysis
- Robustness & uptime - for tough environments
- Flexibility - to accomodate sample size variations
- Performance enhancement - for superior sensitivity
Applications
Zetium Petro edition
The Petro edition, like all Zetium spectrometers, delivers reliable analytical performance regardless of the application and excels in areas related to petrochemicals, such as:
• sulfur in petroleum products in accordance with relevant ISO and ASTM international test methods
• additives in unused lube oils according to ASTM 4927 and D6443
• additives and wear metals in used lube oils
• Single calibration for many oils,fuels and petrochemicals using the Oil-Trace package.
Especificação
| Basic configuration highlights | Configuration upgrades | Benefits |
|---|---|---|
| One application of choice between: Guaranteed fuel compliance S in fuels and oils (ASTM D2622)
Guaranteed lube oil compliance (ASTM D6443) | Additional applications of choice | Guaranteed compliance at start-up with factory pre-calibrated compliance modules:
• S in mineral oil (ASTM D2622) • S in diesel (ASTM D2622) • S in gasoline (ASTM D2622) • Additives in lubrication oils (ASTM D6443) |
| Oil-Trace | Eliminates mass/volume dependence and allows different types of petrochemicals to be measured against a single calibration, eliminating the cost of calibration samples and the time required to maintain multiple calibrations | |
| SST R 1 kW X-ray tube | Maximum uptime with minimum monitor correction | |
| 3 or 4 kW X-ray tube | Faster results and lower detection limits in the same measurement time | |
| Curved crystals for faster results | Up to 30% more intensity in the same measurement time
Shorter measurement time to achieve required limits | |
| Duplex detector | Improved ‘catalyst killer’ elements detection, like nickel, iron and vanadium | |
| SumXcore | Faster results in tandem with the WD functionality
Detect unexpected changes in composition | |
| Small spot mapping | Unique compositional mapping with the ED core, for fast and accurate investigation of pipe scaling and other defects |