Rietveld analysis of electrolytic baths

High-speed XRD systems like CubiX³ Potflux allow the use of standardless methods such as Rietveld quantification. RoboRiet enables the operator to perform such Rietveld quantifications completely automatically and transfers the results to a customer-defined destination (LIMS, paper, table…).

Electrolytic bath (or potflux) analysis with the standard Rietveld method has several advantages: distinction between and determination of the two different Ca-cryolite phases; direct calculation of crucial process parameters like exAlF3 or bath ratio from phase quantification and total calcium data. Results are not influenced by line 

High-speed sample throughput featuring quick turnaround times

Ultra-fast sample loading allows for a higher sample throughput that enables the user to control their processes more effectively. Measurement times below 2 minutes can be easily achieved, depending on the complexity of the bath.

ELBA (Electrolytic Bath Analysis) calibration package

The ELBA (electrolytic bath analysis) calibration package allows the calibration of bath ratios and excess aluminum exAlF3 for new - starting up - plants that do not have their own calibration samples.

High-intensity calcium XRF channel

The software also makes use of a fully integrated high-intensity calcium XRF channel for simultaneous monitoring of elemental Ca concentrations while measuring phase concentrations with diffraction.

Providing the information you need

The CubiX³ Potflux can be used for electrolytic bath analysis of standard baths (optional with Mg or Li addition), Lc analysis (crystallite size) of carbon anodes, the identification of alumina polymorphs and the analysis of bauxites.

GeneralOpticsSample handling
Goniometer: θ-θ for completely horizontal sample handlingCu tubeProgrammable spinner
Diffractometer: 173 mm or 200 mm radiusFixed and programmable divergence, anti-scatter and receiving slits availableUltra-fast pneumatic loader
Software: Industry, optional with Walk-up package, HighScore PlusSecondary monochromator for Cu64 position X’Changer with 2 x 30 positions plus 4 preferred loading positions
Detector: Xe-filled proportional, optionally X’Celerator detector (RTMS)X’Handler for belt connection with 2 additional positions
Fluorescence channel: Closely coupled proportional high-intensity detector for Ca (other elements on request)Automation possible with any automated laboratory

CubiX³ Potflux

Detectors

X'Celerator

Image

The world’s first 1D silicon strip detector for laboratory X-rays

As the world’s first silicon-based position-sensitive 1D detector for XRD, the X’Celerator is the result of the pioneering development from Malvern Panalytical. With the R&D 100 Award-winning X’Celerator detector you can perform XRD measurements up to 100 times faster than with a traditional point detector, without compromising data quality. With no need for cooling water, liquid nitrogen flow, counting gas or time-consuming calibrations, it is a cost-effective solution.

The X’Celerator is designed exclusively for Malvern Panalytical’s diffractometers for applications in research and industry.

Services

Solutions to maximize the return on your investment

To assure that your instrument remains in top condition and performs on the highest level, Malvern Panalytical offers a wide range of services. Our expertise and support services assure an optimal functioning of your instrument.

Support

Service for a lifetime

  • Phone and remote support
  • Preventive maintenance and checkups
  • Flexible Customer Care Agreements
  • Performance certificates
  • Hardware and software upgrades
  • Local and global support

Expertise

Adding value to your processes 

  • Sample preparation development/optimization
  • Analytical methodologies 
  • Turnkey solutions for XRD 
  • Operations via IQ/OQ/PQ, quality assurance (GLP, ISO17025) or round robins/inter laboratory studies
  • Automation of lab processes
  • Consultancy services

Training and education

  • Training on-site or at our competence centers
  • Broad range of basic and advanced courses on products, applications and software

Analytical services and calibration materials

  • Expert (XRF) analyses services
  • Oxides and trace analysis
  • Customized calibration materials
Electrolytic bath analysis for aluminium industries

Application Note

Knowledge center

Want access to free online webinars, white papers, user manuals and much more?

View resources