Epsilon 4 Building materials
Improve your process efficiency through high-quality, low-cost elemental analysis.
X-ray fluorescence spectroscopy (XRF) has an important and well-established analytical role within the cement industry. It is used extensively for production and quality control for the elemental analysis of raw materials, alternative fuels and finished products.
Continuing Malvern Panalytical's successful and established line of benchtop spectrometers, Epsilon 4 provides state-of-the-art XRF analysis. The outstanding analytical performance of Epsilon 4 is comparable to floor-standing XRF instruments, with a much lower cost of ownership.
Discover the possibilities of XRF analysis and reduce your feedback time from hours to minutes by placing the XRF spectrometer next to the production line.
Overview
Value beyond compliance
X-ray fluorescence spectroscopy (XRF) has an important and well-established analytical role within the cement industry. In combination with the Eagon 2 fully
automatic fusion system, the Epsilon 4 complies with the latest cement testing methods of both ASTM C114-15 and ISO 29581-2 in only 10 minutes.
Illustrated below are the significant added values achievable by Epsilon 4, which is just a single modest investment.
Features
The power of benchtop XRF
Combining the latest excitation and detection technologies and smart design, the analytical performance of Epsilon 4 approaches that of more powerful and floor-standing spectrometers. Selective excitation and careful matching of the X-ray tube output to the capabilities of the detection system underlie the system’s outstanding performance.
Accurate results
Unattended operation
Automatic transfer of data to a central location gives you access to the latest results.
Fast and sensitive
Unique detector electronics enable a linear count rate capacity to over 1,500,000 cps (at 50% dead time) and a count rate independent resolution typically better than 135 eV for better separation of analytical lines in the spectrum. This allows the Epsilon 4 spectrometer to run at full power and therefore realizes a much higher sample throughput compared to traditional EDXRF benchtop instruments.
Reduce helium consumption
Specification
Sample handling | X-ray tube | Detector | Software |
---|---|---|---|
10-position removable sample changer | Metal-ceramic side window for maximum stability | High-resolution silicon drift detector (SDD), typically 135 eV @ Mn-Kα | Elemental screening of alternative fuels with Omnian standardless analysis solution |
Spectrometer can accommodate samples up to 52 mm (2 inch) in diameter | 50 micrometers thin beryllium window for high sensitivity for light elements (Na, Mg, Al, Si) | Max. count rate of 1,500,000 counts/s at 50% dead time | PASS/FAIL analysis with FingerPrint solution |
Spinner is included for better accuracy of air filter analysis | Ag anode X-ray tube for best performance of P, S and Cl analysis | Thin-entrance detector window for high sensitivity | One flexible calibration for wear metals in fresh and used lubricating oils using Oil-Trace |
Accessories
Standards (Reference materials)
Software
Epsilon software
Epsilon software is the XRF analysis software platform that is used with PANalytical’s range of Epsilon 1 and Epsilon 4 benchtop EDXRF systems.
Omnian
Omnian software enables users to achieve the best possible analysis when dedicated methods or certified standards do not exist.
Oil-Trace
Oil-Trace is a software package consisting of a suite of standards which enables users to perform accurate and reliable elemental analysis of liquids using WDXRF and EDXRF.FingerPrint
A FingerPrint software module combined with an Epsilon EDXRF system is ideal for material testing when analysis speed is important but the actual composition is not of interest.
Support
Services
Solutions to maximize the return on your investment
To assure that your instrument remains in top condition and performs on the highest level, Malvern Panalytical offers a wide range of services. Our expertise and support services assure an optimal functioning of your instrument.
Support
Service for a lifetime
- Phone and remote support
- Preventive maintenance and checkups
- Flexible Customer Care Agreements
- Performance certificates
- Hardware and software upgrades
- Local and global support
Expertise
Adding value to your processes
- Sample preparation development/optimization
- Analytical methodologies
- Turnkey solutions for XRD
- Operations via IQ/OQ/PQ, quality assurance (GLP, ISO17025) or round robins/inter laboratory studies
- Automation of lab processes
- Consultancy services
Training and education
- Training on-site or at our competence centers
- Broad range of basic and advanced courses on products, applications and software
Analytical services and calibration materials
- Expert (XRF) analyses services
- Oxides and trace analysis
- Customized calibration materials
Key applications
Epsilon 4 spectrometers can handle a large variety of sample types weighing from a few milligrams to larger bulk samples.
Samples can be measured as:
- Solids
- Pressed powders
- Loose powders
- Liquids
- Fused beads
- Slurries
- Granules
- Filters
- Films and coatings