Epsilon 1 Sulfur in fuels

Easiest analysis of sulfur in fuels

Looking for an easy and economical method for compliant analysis of sulfur in fuels? 

Epsilon 1 is the ideal analytical solution. The system is pre-calibrated in the factory and is an out-of-the-box solution with guaranteed performance in compliance with ASTM D4294, ISO 20847, ISO 8754, IP496, IP336 and JIS K2541-4. 

These methods describe the testing for sulfur in petroleum and petroleum products like fuels by XRF.

Download brochure
Request a quote Request a demo Contact sales

Overview

Epsilon 1 is pre-calibrated for sulfur analysis in compliance with the latest international test methods: ASTM D4294, ISO 20847 ISO 8754, IP496, IP336 and JIS K2541-4.

Periodic Table FUELS MP style.jpg

Epsilon 1 is a star-performing benchtop XRF instrument for the analysis of sulfur in fuels according to the latest test methods: ASTM D4294, ISO 20847 ISO 8754, IP496, IP336, and JIS K2541-4. The results of the repeatability test for sulfur are well within the limits set by ASTM D4294, being the most stringent method.

Epsilon1SulfurFuels7.jpg

Features

Maximum sensitivity

The thin window Ag anode X-ray tube, designed and manufactured by Malvern Panalytical, ensures high quality and sensitivity. The selection of Ag as anode material is ideal for the accurate quantification of sulfur without interference of possible line overlaps in the XRF spectrum, leading to more reliable results.
Maximum sensitivity

Self-contained system

A built-in computer running Microsoft Windows 10 with a powerful CPU and 120 GB hard drive ensures flexibility to store and handle thousands of results. The high-resolution, 10.4” LCD touch screen is ideal for easy walk-up operation.

To operate the analyzer, plug into a standard mains connection, and it is ready to power on. 

Self-contained system

Easy communication

USB and network connections for standard computer peripherals support extended use, application development, and seated operator.

Easy communication

Spillage protection

A spillage protection foil is in place to shield the delicate heart of the system. In case of spillage, the foil can be replaced easily by the operator.

Spillage protection

ISO 13032 compliance

Looking for compliant analysis with low running costs?

Epsilon 1 Ultra-Low Sulfur (ULS) is a star-performing benchtop XRF instrument for the analysis of sulfur starting at 5 ppm sulfur in fuels. 

Pre-calibrated in the factory, Epsilon 1 ULS is our out-of-the-box solution for analyzing ultra-low sulfur in automotive fuels in compliance with many relevant test methods, including ISO 13032, TIER 3, and ASTM 4294. Optionally, the instrument comes also pre-calibrated for trace analysis of chlorine in crude oils.  

Epsilon 1 gives you precise and accurate data with minimal sample preparation and no need for using helium - this keeps the total running cost to a minimum. 

Find out more

Looking for compliant analysis with low running costs?

Specification

Sample handlingX-ray tubeDetectorSoftware features
Highly repeatable sample positioningHigh-stability ceramic side windowHigh-resolution, typical 135 eVOperator mode with big buttons for easy operation
Typical 5 ml liquid50 micrometer thin window (Be)8 micrometer thin window (Be)Advanced mode with many features
Spillage protection against liquidsSilver anode, ideal for sulfur analysishigh count-rate capacity
Sulfur analysis in compliance with ASTM D4924 and ISO 20847Software-controlled, max voltage 50 kV

Accessories

Standards (Reference materials)

RoHS

Accurate elemental analysis of RoHS restricted materials
RoHS

TOXEL

Accurate analysis by XRF of toxic elements in polymers and plastics
TOXEL

CRMs

Claisse is always there to meet your needs!
CRMs

Software

Epsilon software

Epsilon software is the XRF analysis software platform that is used with PANalytical’s range of Epsilon 1 and Epsilon 4 benchtop EDXRF systems.

Epsilon software

Stratos

The software provides a rapid, simple and non-destructive means of analyzing coatings, surface layers and multi-layered structures.
Stratos

Omnian

Omnian software enables users to achieve the best possible analysis when dedicated methods or certified standards do not exist.

Omnian

FingerPrint

A FingerPrint software module combined with an Epsilon EDXRF system is ideal for material testing when analysis speed is important but the actual composition is not of interest.

FingerPrint

Support

Services

Solutions to maximize the return on your investment

To assure that your instrument remains in top condition and performs on the highest level, Malvern Panalytical offers a wide range of services. Our expertise and support services assure an optimal functioning of your instrument.

Support

Service for a lifetime

  • Phone and remote support
  • Preventive maintenance and checkups
  • Flexible Customer Care Agreements
  • Performance certificates
  • Hardware and software upgrades
  • Local and global support

Expertise

Adding value to your processes 

  • Sample preparation development/optimization
  • Analytical methodologies 
  • Turnkey solutions for XRD 
  • Operations via IQ/OQ/PQ, quality assurance (GLP, ISO17025) or round robins/inter laboratory studies
  • Automation of lab processes
  • Consultancy services

Training and education

  • Training on-site or at our competence centers
  • Broad range of basic and advanced courses on products, applications and software

Analytical services and calibration materials

  • Expert (XRF) analyses services
  • Oxides and trace analysis
  • Customized calibration materials