Value beyond compliance

X-ray fluorescence spectroscopy (XRF) has an important and well-established analytical role within the cement industry. In combination with the Eagon 2 fully
automatic fusion system, the Epsilon 4 complies with the latest cement testing methods of both ASTM C114-15 and ISO 29581-2 in only 10 minutes.
Illustrated below are the significant added values achievable by Epsilon 4, which is just a single modest investment.

The power of benchtop XRF

Combining the latest excitation and detection technologies and smart design, the analytical performance of Epsilon 4 approaches that of more powerful and floor-standing spectrometers. Selective excitation and careful matching of the X-ray tube output to the capabilities of the detection system underlie the system’s outstanding performance.

The power of benchtop XRF

Accurate results

The unique high-performance, metal-ceramic X-ray tube, specifically designed and manufactured by Malvern Panalytical, ensures high-quality data and reliable results. Flexible voltage settings from 4.0 to 50 kV and a maximum current setting up to 3.0 mA optimize the performance across the periodic table.
Accurate results

Unattended operation

The combination of a 10-position removable sample changer with spinner enables the automatic processing of sample batches without the need for operator attention. Continuous rotation of the sample during measurement minimizes any errors caused by non-homogeneity or surface irregularities within individual samples and provides more accurate results.
Automatic transfer of data to a central location gives you access to the latest results.
Unattended operation

Fast and sensitive

Fast measurements are achieved by using the latest silicon drift detector technology that produces significantly higher intensities.
Unique detector electronics enable a linear count rate capacity to over 1,500,000 cps (at 50% dead time) and a count rate independent resolution typically better than 135 eV for better separation of analytical lines in the spectrum. This allows the Epsilon 4 spectrometer to run at full power and therefore realizes a much higher sample throughput compared to traditional EDXRF benchtop instruments.
Fast and sensitive

Reduce helium consumption

The high performance of Epsilon 4 enables many applications to be operated in air atmosphere, without longer overhead time and costs involved for helium or maintenance of vacuum system. When measuring in air, low-energy X-ray photons characteristic of sodium, magnesium and aluminium, are sensitive to variations in air pressure and temperature. Built-in temperature and air-pressure sensors compensate for these environmental variations, ensuring excellent results whatever the weather.
Reduce helium consumption
Sample handlingX-ray tubeDetectorSoftware
10-position removable sample changerMetal-ceramic side window for maximum stabilityHigh-resolution silicon drift detector (SDD), typically 135 eV @ Mn-KαElemental screening of alternative fuels with Omnian standardless analysis solution
Spectrometer can accommodate samples up to 52 mm (2 inch) in diameter50 micrometers thin beryllium window for high sensitivity for light elements (Na, Mg, Al, Si)Max. count rate of 1,500,000 counts/s at 50% dead timePASS/FAIL analysis with FingerPrint solution
Spinner is included for better accuracy of air filter analysisAg anode X-ray tube for best performance of P, S and Cl analysisThin-entrance detector window for high sensitivityOne flexible calibration for wear metals in fresh and used lubricating oils using Oil-Trace

Services

Solutions to maximize the return on your investment

To assure that your instrument remains in top condition and performs on the highest level, Malvern Panalytical offers a wide range of services. Our expertise and support services assure an optimal functioning of your instrument.

Support

Service for a lifetime

  • Phone and remote support
  • Preventive maintenance and checkups
  • Flexible Customer Care Agreements
  • Performance certificates
  • Hardware and software upgrades
  • Local and global support

Expertise

Adding value to your processes 

  • Sample preparation development/optimization
  • Analytical methodologies 
  • Turnkey solutions for XRD 
  • Operations via IQ/OQ/PQ, quality assurance (GLP, ISO17025) or round robins/inter laboratory studies
  • Automation of lab processes
  • Consultancy services

Training and education

  • Training on-site or at our competence centers
  • Broad range of basic and advanced courses on products, applications and software

Analytical services and calibration materials

  • Expert (XRF) analyses services
  • Oxides and trace analysis
  • Customized calibration materials