NanoSight LM10
Entry level, manual system
The Malvern Panalytical NanoSight LM10 instrument provides an easy-to-use, reproducible platform for nanoparticle characterization.
The LM10 allows rapid and accurate analysis of the size distribution and concentration of all types of nanoparticles from 20nm-1000nm* in diameter, depending on the instrument configuration and sample type.
*Sample and system configuration dependent
Overview
The Malvern Panalytical NanoSight LM10 is a flexible and robust instrument that can be upgraded at any time to fit the changing needs of both routine testing and research laboratories.
- Visual validation of results gives extra confidence
- Minimal sample preparation
- Laser module with a temperature control
- Choice of interchangeable laser blocks and wavelengths
How it works
The Malvern Panalytical NanoSight LM10 uses the technology of Nanoparticle Tracking Analysis (NTA). This unique technology utilizes the properties of both light scattering and Brownian motion in order to obtain the size distribution and concentration measurement of particles in liquid suspension. A laser beam is passed through the sample chamber, and the particles in suspension in the path of this beam scatter light in such a manner that they can easily be visualized via a 20x magnification microscope onto which is mounted a camera. The camera operates at 30 frames per second (fps), capturing a video file of the particles moving under Brownian motion. The software tracks many particles individually and using the Stokes-Einstein equation calculates their hydrodynamic diameters.
Specification
General
- Wavelength:
- 405nm (violet), 488nm (blue) or 532nm (green).
- Temperature control range:
- 5°C below ambient to 50°C.
- Stage:
- Manual stage.
- Focus:
- Manual focus.
- Camera:
- CCD.
- Dimensions (W, D, H):
- 420mm x 200mm x 260mm.
- Particle size:
20nm - 1000nm*
*Sample and system configuration dependent
- Concentration range:
- 106 to 109 particles per mL.
- Power:
- 100V - 240V
Accessories
NanoSight LM10
NanoSight syringe pump
The Malvern Panalytical NanoSight syringe pump is available for all Malvern Panalytical NanoSight systems, enabling analysis in constant flow for improved sample statistics and measurement of photo-bleaching fluorescent samples.
Support
Protect your investment and ensure optimized performance at all times with Malvern Panalytical's service plans.
When you purchase a Malvern Panalytical product we understand that this is just the first stage of a working relationship that will last for the lifetime of the instrument. Depending on your needs, Malvern Panalytical will provide the support for your business.
Help Desk
- Telephone and email support.
- Operators who take responsibility for your call and ensure your query is answered.
Training
Software downloads
Malvern Panalytical's service options- choose the right plan for you:
Malvern Panalytical Platinum Plan
For laboratories where maximizing instrument up-time is critical to its daily performance. Our highest level of response and the 'all inclusive' price plan takes care of those unexpected repair bills should the unfortunate occur.
Malvern Panalytical Gold Plan
Enhance your laboratory productivity by maintaining instrument efficiency. Still receive that priority response, combined with specialist technical and software support, we'll keep your instrument performance on track to deliver.
Malvern Panalytical Bronze Visit
For laboratories looking to optimize instrument performance, regular preventative maintenance is essential.
Platinum Plan | Gold Plan | Bronze Visit | |
---|---|---|---|
Annual PM/PV Test | yes | yes | no |
Telephone / Email Support | yes | yes | no |
Priority Response | yes | yes | no |
Emergency Breakdown visits* | yes | yes | no |
Parts Included | yes | no | no |
Technical & Software Support | yes | yes | yes |
IQ/OQ (Pharma)*** | yes | yes | yes |
*including labour & travel costs***available at an additional cost