OMNISEC is a powerful tool for taking control of the performance, quality and value of your product, whether that’s a synthetic polymer in industry, a natural polymer or polysaccharide used in food or pharmaceutical products, or a protein or antibody used in biopharmaceuticals.

As a research tool, it accelerates research into these molecules by providing absolute information for a wide range of applications making it an ideal tool for universities. It reduces service expense and downtime and increases productivity with easy-to-use intuitive software.

With OMNISEC you can…Of…
Control strength, toughness, durability, brittleness, processability and branchingPolystyrene, nylon, PET, PVC, polyester, nitrocellulose, resins, epoxys, polyurethanes, PVA
Measure degradation and drug delivery ratesPLA, PLGA, PEG, polycaprolocatone
Grade natural polymers and polysaccharidesAlginates, xanthans, Gum Arabic, starch derivatives (e.g. maltodextrin), cellulose derivatives (e.g. HEC), carageenan, gelatin, guar gum, chitosan, hyaluronic acid
Control formulation viscosityAlkyds, acrylics, polyurethanes, polyesters, resins, epoxys, PVA,
Control food mouth-feel and gellingPectins, alginates, xanthans, Gum Arabic, guar gum, starch derivatives (e.g. maltodextrin), carageenans
Assess and predict activity by measuring molecular weightProteins, antibodies, mAbs
Predict and understand immunogenicity and efficacyAggregates of proteins, biopharmaceuticals, biologics and mAbs
Control half-life, cell permeability and understand crystallization of protein conjugatesPEGylated proteins, membrane proteins, antibody-drug-conjugates

In size-exclusion chromatography, molecules are separated according to their hydrodynamic radius as they enter and exit the pores of a porous gel packing matrix in the column. Like other HPLC-based techniques, this involves the use of a pump, column and at least one detector to measure the sample as it elutes. An OMNISEC GPC/SEC system includes the following components:

Degasser

  • Rapid mobile-phase exchange thanks to low volume degasser

Pump

  • Rapid mobile-phase exchange thanks to self-priming pump
  • Reduced service requirement thanks to novel continuous back seal flushing mechanism

Autosampler

  • Protect samples from aggregation with autosampler temperature control
  • Use your preferred sample format; vials or 96-well microtiter plates
  • Reduce sample use with zero-waste mode

Column Oven

  • Temperature control of up to 6 analytical columns

Refractive Index

  • Measure the concentration of any solute with excellent sensitivity

UV/Vis PDA

  • Measure absorbance at any wavelength from 190-900 nm
  • Assess changes in absorbance spectra
  • Characterize copolymers

Light Scattering

  • Measure absolute molecular weight in a wider range of applications
  • Measure as little as 100 ng of material
  • Measure molecular weights down to 200 Da

Viscometer

  • Better intrinsic viscosity measurements thanks to automated balancing
  • Reduced service cost and time thanks to user-exchangeable capillaries

OMNISEC RESOLVE

Pump flow rate:
0.005 - 10 mL/min
Flow rate accuracy:
±1%
Pressure range:
0 - 5000 PSI (34.5 MPa)
Pulsation:
0.15% @ 1 mL/min in water
Dimensions (W, D, H):
420, 640, 890 mm
Weight:
62 kg
Software:
OMNISEC software v10 (or later)
Data acquisition rate:
100 Hz
Patents:
US 14/599,033 "Continuous back seal wash"

AUTOSAMPLER

Capacity:
Up to 192
Sample container types:
HPLC vials or 96-well microtiter plates
Injection volume:
1 - 300 µL
Injection volume accuracy:
>99.5%
Injection volume precision:

<0.3% RSD in full loop mode

<0.5% RSD in partial loop mode

<1% RSD in µL pickup mode

Injection overhead volume:
0 µL in µL pickup mode
Syringe volume:
250 µL standard
Temperature control range:
4 - 60 °C

COLUMN OVEN

Column capacity:
6 x analytical (1 x Tricorn 10/300 GL)
Temperature control range:
20 - 65 °C

OMNISEC REVEAL

Dimensions (W, D, H):
420, 640, 600 mm
Weight:
40 kg
Detector temperature range:
20 - 65 °C
Software:
OMNISEC software v10 (or later)
Data acquisition rate:
100 Hz
Patents:

US20140060162A1 & EP2619543Ba "Modular capillary bridge viscometer"

US20140144214A1 & EP2619544A1 "Automatically balanced capillary bridge viscometer"

Detector 1

Detector:
Light scattering
Measurement principle:
RALS 90° angle, LALS 7° angle
Light source:
50 mW, 640 nm laser
Cell volume:
18 µL
Dynamic range:
2500 mV
Baseline noise:
<0.1 mV
Baseline drift:
<0.2 mV/hr

Detector 2

Detector:
Differential refractive index
Measurement principle:
Deflection
Cell volume:
12 µL
Dynamic range:
±2.5 x 10-4 RIU
Baseline noise:
<10-7 RIU
Baseline drift:
<3 x 10-7 RIU/hr

Detector 3

Detector:
Viscometer
Measurement principle:
4-capillary Wheatstone bridge with self-balancing mechanism and user-exchangeable capillaries
Transducers:
Firmware-based transducer overpressure protection
Detector volume:
17 µL/capillary
Differential pressure baseline noise:
0.3 Pa
Inlet pressure dynamic range:
100 kPa
Inlet pressure baseline noise:
0.01 kPa
Baseline drift:
<0.2 kPa/hr

Detector 4

Detector:
Diode-array-based UV/Vis spectrometer
Wavelength:
190 - 900 nm
Number of wavelengths:
1024
Wavelength accuracy:
<1 nm
Wavelength resolution:
0.6 nm
Cell volume:
7.5 µL
Path length:
10 mm
Baseline noise:
2 x 10-5 AU
Baseline drift:
5 x 10-4 AU/hr

Measurement type 1

Measurement type:
Absolute molecular weight
Measurement range:
200 - >107 g/mol
Minimum quantifiable mass:
100 ng of 100kDa molecular weight polystyrene in THF
Measurement principle:
Light scattering (LALS or RALS)

Measurement type 2

Measurement type:
Intrinsic viscosity
Minimum quantifiable mass:
1 µg of 100kDa molecular weight polystyrene in THF
Measurement principle:
4-capillary Wheatstone bridge

Measurement type 3

Measurement type:
Concentration
Minimum quantifiable mass:
100 ng of 100kDa molecular weight polystyrene in THF
Measurement principle:
Differential refractive index detection

Operating environment

Temperature:
15 - 30 °C

Software

Minimum computer specification:
Windows 7 Professional 64 bit, 4th Gen Intel(R) Core I7 Processor (Quad Core HT, 3.4 GHz Turbo, w/ HD Graphics), 8 GB 1600 MHz DDR3 memory, 500 GB 3.5 inch SATA (7200 RPM) HDD, Full-HD monitor

OMNISEC

OMNISEC RESOLVE

Image

Combined pump, degasser, autosampler and column oven, for high quality GPC/SEC and accurate molecular weight measurement.

OMNISEC RESOLVE combines with OMNISEC REVEAL to form a complete OMNISEC GPC/SEC solution for the measurement of absolute molecular weight, intrinsic viscosity and other parameters. It combines an integrated pump, degasser, autosampler and column oven in a single advanced separations unit.

More information

OMNISEC REVEAL

Image

The ultimate in integrated advanced detection for GPC/SEC

Molecular weight, intrinsic viscosity and numerous other parameters can be measured with OMNISEC REVEAL, the world’s most advanced integrated GPC/SEC multi-detector available. It can be added to any existing conventional GPC/SEC system or used in conjunction with OMNISEC RESOLVE to form a complete GPC/SEC solution, to offer comprehensive molecular characterization of synthetic and natural polymers, as well as proteins.

More information

OMNISEC software

Image

Powerful, agile, easy to use GPC/SEC software for OMNISEC instrument control, data acquisition, analysis and reporting

OMNISEC software is an integrated solution for the advanced analysis of proteins and polymers by GPC/SEC, and is specifically designed for control of OMNISEC RESOLVE and OMNISEC REVEAL. Simplified workflows improve productivity and help you to maximize the information and efficiency of your experiments. Simply load your samples and the software controls all the sequencing, enabling truly automatic unattended operation.

More information

GPC and SEC Columns

Image

GPC/SEC columns for all aqueous and organic applications

A wide range of columns for analytical GPC/SEC of synthetic and natural polymers and proteins.

More information

GPC and SEC Standards

Image

A range of molecular weight standards for different applications of GPC/SEC

Malvern offers a wide range of molecular weight standards for GPC/SEC for conventional and universal calibration as well as light scattering.

More information

Protect your investment and ensure optimized performance at all times with Malvern Panalytical's service plans.

When you purchase a Malvern Panalytical product we understand that this is just the first stage of a working relationship that will last for the lifetime of the instrument. Depending on your needs, Malvern Panalytical will provide the support for your business.

Help Desk

Training

Software downloads

Malvern Panalytical's service options- choose the right plan for you:

Malvern Panalytical Platinum Plan

For laboratories where maximizing instrument up-time is critical to its daily performance. Our highest level of response and the 'all inclusive' price plan takes care of those unexpected repair bills should the unfortunate occur.

Malvern Panalytical Gold Plan

Enhance your laboratory productivity by maintaining instrument efficiency. Still receive that priority response, combined with specialist technical and software support, we'll keep your instrument performance on track to deliver.

Malvern Panalytical Bronze Visit

For laboratories looking to optimize instrument performance, regular preventative maintenance is essential.

Platinum PlanGold PlanBronze Visit
Annual PM/PV Test
yes
yes
no
Telephone / Email Support
yes
yes
no
Priority Response
yes
yes
no
Emergency Breakdown visits*
yes
yes
no
Parts Included
yes
no
no
Technical & Software Support
yes
yes
yes
IQ/OQ (Pharma)***
yes
yes
yes

*including labour & travel costs***available at an additional cost