The Viscotek RI Detector is sold as part of the Viscotek 270max system, or as a stand-alone module for connection to other chromatography components, such as the GPCmax, UV/Vis or PDA detectors.

  • Two temperature control profiles enable use at normal laboratory temperature or in cold room/cabinet conditions.
  • Automatically purged from the software or as part of a programmed sample sequence.
  • Carefully designed purging system minimizing major temperature changes, giving rapid baseline recovery.

A pump, such as the GPCmax, and some form of injection device, such as a manually actuated valve or autosampler, is connected to the RI detector. Mobile phase (and sample) enters the RI detector and passes through a dual compartment flow cell. One side of the compartment contains the reference solvent, and the other side contains the mobile phase that is constantly flowing through the detector.

Dissolved compounds cause a difference in the refractive index of the mobile phase when compared to the reference solvent, which in turn gives a change in the output of the detector. The output of the detector is directly proportional to the concentration of the compounds present in solution.

General

Dimensions (W, D, H):
220mm x 350mm x 160mm
Weight:
12 kg

Detector 1

Detector:
RI Detector VE3580
Measurement principle:
Deflection
Light source:
Tungsten Lamp
Cell volume:
9µL
Purging:
Manual, automatic and programmable
Data acquisition rate:
5Hz to OmniSEC
Temperature control range:
35° - 55°C in 1°C steps – normal environment. 10° - 30°C in 1°C steps – cold room environment

Measurement type 1

Measurement principle:
Differential Refractive Index detection

Operating environment

Temperature:
15°C – 40°C
Humidity:
35% - 80% non-condensing

Protect your investment and ensure optimized performance at all times with Malvern Panalytical's service plans.

When you purchase a Malvern Panalytical product we understand that this is just the first stage of a working relationship that will last for the lifetime of the instrument. Depending on your needs, Malvern Panalytical will provide the support for your business.

Help Desk

Training

Software downloads

Malvern Panalytical's service options- choose the right plan for you:

Malvern Panalytical Platinum Plan

For laboratories where maximizing instrument up-time is critical to its daily performance. Our highest level of response and the 'all inclusive' price plan takes care of those unexpected repair bills should the unfortunate occur.

Malvern Panalytical Gold Plan

Enhance your laboratory productivity by maintaining instrument efficiency. Still receive that priority response, combined with specialist technical and software support, we'll keep your instrument performance on track to deliver.

Malvern Panalytical Bronze Visit

For laboratories looking to optimize instrument performance, regular preventative maintenance is essential.

Platinum PlanGold PlanBronze Visit
Annual PM/PV Test
yes
yes
no
Telephone / Email Support
yes
yes
no
Priority Response
yes
yes
no
Emergency Breakdown visits*
yes
yes
no
Parts Included
yes
no
no
Technical & Software Support
yes
yes
yes
IQ/OQ (Pharma)***
yes
yes
yes

*including labour & travel costs***available at an additional cost