The Viscotek SEC-MALS 20 is a modular multi angle light scattering detector that can easily be used with any existing SEC system, adding the power of light scattering detection for molecular weight and molecular size measurements. It can also be purchased as part of a complete system package. The signals from the SEC-MALS and other detectors connected to the system are analyzed by the most advanced GPC software available, OmniSEC.

The SEC-MALS 20 can be used to measure the absolute molecular weight and oligomeric state of proteins, independent of retention time. It can also be used to analyse natural and synthetic polymers, including the measurement of molecular size over the widest possible range.

The SEC-MALS 20 is part of a range of Viscotek light scattering detectors offering maximum choice of system from a single supplier.

  • Up to 20 angles for more accurate results
  • Measure absolute molecular weight and Rg
  • Can be combined with any existing SEC system
  • A single powerful software package to control the system and analyse data - OmniSEC
  • Vertical flow cell with advanced radial optics for improved performance
  • Stable and sensitive low angle detectors improve accuracy
  • Small footprint

The SEC-MALS 20 multi angle light scattering detector is connected to the output of any SEC or GPC system, such as the Viscotek TDAmax. Signals generated from the sample passing through all detectors are analyzed by OmniSEC software.

The SEC-MALS system consists of 20 detectors arranged around a vertical flow cell to detect scattered light at a wide range of angles.

The angular intensity and concentration information is combined to construct a plot, which is used in two ways. Firstly to extrapolate the data to determine the scattered light intensity at zero angle, from which the absolute molecular weight is calculated. Secondly to determine the initial slope of the plot which is related to the radius of gyration of the molecule (Rg).

If the system configuration includes a viscometer, the combination of molecular weight and intrinsic viscosity data can be used to calculate the hydrodynamic diameter of the sample along with information on branching. 

Detectors 1

Detector:
SEC-MALS 20
Measurement principle:
Multi-Angle Light Scattering
Light source:
660nm, 120 mW laser
Number of angles:
20
Cell volume:
63 µL
Detector type:
Custom photodiodes
Data acquisition rate:
5 Hz

Measurement type 1

Measurement type:
Molecular Weight
Measurement range:
<1000 – >107 g/mol
Molecular weight accuracy:
±2% for NIST standard SRM 1478
Measurement principle:
Multi-Angle Light Scattering (MALS)
Data models:
Zimm, Berry, Debye
Minimum sample required:
1 µg 105 kDa Polystyrene, 2 µg BSA

Measurement type 2

Measurement type:
Radius of Gyration (Rg)
Measurement range:
10 – 150 nm
Measurement principle:
Multi-Angle Light Scattering (MALS)
Data models:
Zimm, Berry, Debye

General

Temperature range:
Ambient to 60°C
Analogue signals accepted:
4 x ±10 V 24 bit
Laser safety:
Class 1
Power:
90-250V, 50/60 Hz
Power consumption:
60W
Dimensions (W, D, H):
26cm, 46cm, 16cm
Weight:
16.5kg
Temperature:
15°C – 30°C
Humidity:
35% - 80% non-condensing
Software:
OmniSEC 5.0 or higher

Protect your investment and ensure optimized performance at all times with Malvern Panalytical's service plans.

When you purchase a Malvern Panalytical product we understand that this is just the first stage of a working relationship that will last for the lifetime of the instrument. Depending on your needs, Malvern Panalytical will provide the support for your business.

Help Desk

Training

Software downloads

Malvern Panalytical's service options- choose the right plan for you:

Malvern Panalytical Platinum Plan

For laboratories where maximizing instrument up-time is critical to its daily performance. Our highest level of response and the 'all inclusive' price plan takes care of those unexpected repair bills should the unfortunate occur.

Malvern Panalytical Gold Plan

Enhance your laboratory productivity by maintaining instrument efficiency. Still receive that priority response, combined with specialist technical and software support, we'll keep your instrument performance on track to deliver.

Malvern Panalytical Bronze Visit

For laboratories looking to optimize instrument performance, regular preventative maintenance is essential.

Platinum PlanGold PlanBronze Visit
Annual PM/PV Test
yes
yes
no
Telephone / Email Support
yes
yes
no
Priority Response
yes
yes
no
Emergency Breakdown visits*
yes
yes
no
Parts Included
yes
no
no
Technical & Software Support
yes
yes
yes
IQ/OQ (Pharma)***
yes
yes
yes

*including labour & travel costs***available at an additional cost