Zetasizer Pro
High performance, versatile and robust
The new Zetasizer Pro is your go-to instrument to measure a wide range of sample types and concentrations. It offers wide dynamic concentration capability and high sensitivity due to the Non-Invasive Back Scatter (NIBS) optical design. Measurement of particle size, molecular size, electrophoretic mobility, zeta potential and molecular weight can all be performed with ease.
The Adaptive Correlation feature enhances sample throughput by reducing measurement duration and providing greater sample knowledge. The deep learning-based data quality system gives you the confidence to know your data is the best it can be.
The optical filter wheel allows measurement of fluorescent samples without impacting overall instrument sensitivity.
Features and benefits
Works with OmniTrust: Malvern Panalytical's compliance solution for the regulated environment
Even novice users will produce the highest-quality measurements using the Zetasizer Pro, which benefits from:
- Dynamic Light Scattering (DLS), which measures particle and molecule size, from 0.3 nm to 10 µm
- Electrophoretic Light Scattering (ELS), which measures the zeta potential of particles and molecules, indicating sample stability and/or propensity to aggregate
- Non-Invasive Back Scatter (NIBS), optics for versatile, high sensitivity, particle and molecular size measurements and molecular weight measurements
- M3-PALS with Constant Current Mode, for zeta potential and electrophoretic mobility measurements
- ZS Xplorer software suite, for simple and flexible method set-up and data analysis
- Adaptive Correlation, for faster, more reproducible sizing measurements with less sample preparation
- Deep learning-based data quality system, for assessment of any size data quality issues, with clear advice on how to improve results
- Optical filter wheel with fluorescence filter, to allow measurement of fluorescent samples without impairing overall system sensitivity. Also includes polarization filters for DDLS measurements
- Available in Blue Label and Red Label variants:
- Choose Blue Label for routine sample investigation such as metallic colloids, metal oxides and pigments
- Choose Red Label for more challenging sample types, such as proteins, surfactant solutions and low solid content samples
- On-site upgradeability to Zetasizer Ultra, should your requirements change
- The optional MPT-3 Autotitrator enables study of the effect of changes in pH
- A range of disposable and reusable cells are available to optimize the measurement in terms of sample volume and concentration
Key applications
The Zetasizer Pro is used for many applications, including:
Academia
The Zetasizer Pro is an essential analytical tool for many academic laboratories worldwide, finding use in all applications where particle or molecular size and zeta potential analysis is required. The breadth of applications covered by Zetasizer systems, coupled with tens of thousands of scientific citations, have earned these instruments a central space in many scientific faculties.
Bioscience
Variations in molecule concentration, external temperature, level of agitation and time all impact the stability of biological molecules. Instabilities mainly result in denaturation and aggregation of the molecule through which they can lose their biological function , elicit an immune response and consequently limit its therapeutic viability. Factors affecting therapeutic efficacy and immunogenicity therefore need to be monitored throughout the development pipeline especially at early stages to de-risk the biological drug molecule and limit late-stage failures. The Zetasizer range provides high quality, stability indicating data for biological drug molecules in a short time frame, enabling this measurement to be implemented throughout the development pipeline.
Food and drink
Zetasizer systems are used to analyze particle size and zeta potential to improve the appearance and taste of foods, drinks and flavorings, and optimize dispersion and emulsion stability to extend product shelf life and improve product performance.
Nanomaterials
Zetasizer measurements of nanoparticle size distribution, dispersion properties, stability and propensity to aggregate are crucial to the design of new nanomaterials. The very large surface area of such materials may result in novel physical and chemical properties, such as increased catalytic activity, improved solubility or unexpected optical or toxicological behaviour.
Paints, inks and coatings
Paint, ink and coating formulations must be stable to keep them in an optimum state over time without change or aggregation. Particle size and zeta potential, measured by the Zetasizer instruments, play important roles in determining a product’s properties, such as dispersibility, color, strength, finish, durability and shelf life.
Pharmaceuticals
The correct particle size and zeta potential can help ensure the production of effective therapeutics, delivered safely. Zetasizer systems are used to characterize the stability and quality of dispersions, emulsions and creams, reducing formulation time and speeding new products to market.
Specification
Particle size and molecular size
- Measurement principle:
- Non-Invasive Back Scatter (NIBS)Dynamic Light Scattering
- Measurement angle:
- 173°, 13°
- Measurement range:
- Diameter: 0.3 nm - 10 μm
- Minimum sample volume:
- 12 μL
- Concentration range:
- Minimum sample concentration:Blue Label: 0.2 mg/mL 15 kDa ProteinRed Label: 0.1 mg/mL 15 kDa ProteinMaximum sample concentration: (3)40% w/v
Zeta potential
- Measurement principle:
- Mixed-Mode Measurement phase analysis light scattering (M3-PALS)
- Size range:
- Diameter: 3.8 nm – 100 μm (2)
- Minimum sample volume:
- 20 μL (4)
- Concentration range:
- Red Label: 1 mg/mL (5) to 40% w/v (6)Blue Label: 10 mg/mL (5) to 40% w/v (6)
- Sample conductivity range:
- Maximum: 260 mS/cm
Static Light Scattering (molecular weight)
- Molecular weight range:
- 980 Da – 20 MDa
- Measurement principle:
- Static Light Scattering with Debye Plot
- Accuracy:
- +/- 10% typical
System
- Detector:
- Avalanche Photodiode
- Laser safety:
- He-Ne (633 nm)Blue label: 4 mW MaxRed label: 10 mW Max
- Temperature control range:
- 0°C - 120°C (7)
- Dimensions (W, D, H):
- 322 mm x 565 mm x 245 mm
- Weight:
- 19 kg
- Power:
- AC 100-240 V, 50-60 Hz, 4.0 A
- Power consumption:
- Max 100 W, Typical 45 W
- Ambient conditions:
- +10°C to +35°C, 35 to 80% RH (Non-condensing)
- Interface:
- USB 2.0 or higher
Footnotes
- Notes:
- 1 - Water as dispersant2 - Indicative data available for particle sizes greater than 10 μm when using Extended Size Range analysis and low volume disposable sizing cell accessory3 - Sample dependent4 - Using patented diffusion barrier technique5 - Measured using 15 kDa protein6 - Measured using bile acid7 - Dry nitrogen cell purge required for temperatures below dewpoint8 - Accuracy 0.1°C at 25°C, 0.2°C at 0°C, 0.5°C at 90°C
Accessories
Zetasizer Pro
Accessories
SV-10 viscometer
Viscosity measurement with speed, simplicity and accuracy.
The SV-10 measures viscosity with the accuracy required for dynamic light scattering, for the conversion of diffusion speed to size, and electrophoretic mobility to zeta potential, in an extremely simple and rapid system.
MPT-3 Autotitrator
Automate your pH titrations
The MPT-3 is a cost-effective accessory for the Zetasizer Advance range, designed to automate your Zeta and/or Size vs. pH titrations, helping you understand how your materials behave as a function of pH.
The zeta potential and/or size of your materials with pH changes can be critical in understanding:
- Material stability
- Agglomeration
- Flocculation
- Point of net-zero charge (isoelectric point)
- Storage conditions
Cell & cuvette options
Disposable folded capillary cell (DTS1070)
Eliminate sample cross contamination between zeta potential measurements using a completely disposable cell.
The zeta potential of colloids and molecules is extremely sensitive to contamination from components of a previous sample used in a measurement cell. The use of a disposable cell completely eliminates this potential contamination issue.
The folded capillary cell provides the benefits of the accuracy of measurement of a capillary cell with the ease of use of a disposable cell.
Although, disposable, including the electrodes, for low conductivity samples each cell can be used for hundreds of measurements if required.
The cell can be used with the autotitrator, where multiple measurements are routinely done over a wide pH range.
Universal 'dip' cell kit
Reusable solvent resistant cell.
The dip cell is used for the measurement of zeta potential of samples in aqueous and non-aqueous dispersants, and is designed to be cleaned and reused. It is for batch measurements using standard polystyrene or glass cuvettes.High concentration zeta potential cell kit
Save time and effort by measuring zeta potential with little or no dilution.
The high concentration cell enables the measurement of the zeta potential of samples with little or no dilution in any Zetasizer Advance system that measures zeta potential.
The cell has a flow configuration so can be used for stop-flow size and zeta potential measurements using an MPT-3 autotitrator as well as batch measurements.
12mm square glass cell (PCS8501)
Glass cuvette for batch measurements.
- For size and molecular weight measurements
- Compatible with aqueous and non-aqueous solvents and dispersants
12mm Glass cell (PCS1115)
Glass cuvette for use with the dip cell.
- For size and zeta potential measurements using the ‘dip’ cell
- Compatible with aqueous and non-aqueous solvents and dispersants
Low-volume quartz batch cuvette (ZEN2112)
Low-volume quartz batch cuvette for size and molecular weight measurements.
- Compatible with size and molecular weight measurements with aqueous and non-aqueous solvents and dispersants
- Minimum sample volume 12 microliters
- Maximum volume 45 microliters
12mm Square Polystyrene Cuvettes (DTS0012)
Disposable polystyrene cuvettes.
- 100 disposable cells complete with 100 stoppers to avoid cross-contamination
- For size measurements using aqueous dispersants
- Compatible with zeta potential measurements using the dip cell
Disposable Solvent Resistant Micro Cuvette (ZEN0040)
Disposable plastic micro cuvette, for size measurement at 173° (NIBS) optics only.
- 100 x 40µL cuvettes with 100 caps to avoid cross-contamination
- Compatible with aqueous samples and a range of other solvents: Acetone, Benzaldehyde, Butanone, Dioxane, DMF, Ethyl acetate, Isopropanol, plus various acids and bases
Support
Protect your investment and ensure optimized performance at all times with Malvern Panalytical's service plans.
When you purchase a Malvern Panalytical product we understand that this is just the first stage of a working relationship that will last for the lifetime of the instrument. Depending on your needs, Malvern Panalytical will provide the support for your business.
Help Desk
- Telephone and email support.
- Operators who take responsibility for your call and ensure your query is answered.
Training
Software downloads
Malvern Panalytical's service options- choose the right plan for you:
Malvern Panalytical Platinum Plan
For laboratories where maximizing instrument up-time is critical to its daily performance. Our highest level of response and the 'all inclusive' price plan takes care of those unexpected repair bills should the unfortunate occur.
Malvern Panalytical Gold Plan
Enhance your laboratory productivity by maintaining instrument efficiency. Still receive that priority response, combined with specialist technical and software support, we'll keep your instrument performance on track to deliver.
Malvern Panalytical Bronze Visit
For laboratories looking to optimize instrument performance, regular preventative maintenance is essential.
Platinum Plan | Gold Plan | Bronze Visit | |
---|---|---|---|
Annual PM/PV Test | yes | yes | no |
Telephone / Email Support | yes | yes | no |
Priority Response | yes | yes | no |
Emergency Breakdown visits* | yes | yes | no |
Parts Included | yes | no | no |
Technical & Software Support | yes | yes | yes |
IQ/OQ (Pharma)*** | yes | yes | yes |
*including labour & travel costs***available at an additional cost
Self-Install
Get your new Zetasizer Advance system up and running faster when you choose to self-install.
With comprehensive resources to help you quickly and safely set-up and verify the performance of your new instrument, there’s no need to wait for an engineer to do it for you. What’s more, self-install presents a new training opportunity as you receive full access to exclusive training material.
How does it work?
When you follow the step-by-step video instructions, you could be up and running within 60 minutes of delivery of your new Zetasizer Advance system.
You don't need any specific skills or knowledge to perform a self-install. Simply follow the instructions provided. Everything needed to get started is provided with your new instrument – all you need is an internet connection to access the online training.
Exclusive e-learning content
Resources to get you up and running quickly and with confidence include:
- detailed video guides walk you through installation and set-up
- 15 months' access to the Essentials e-learning course, which is provided at no extra cost
- a comprehensive user manual