The Zetasizer Nano ZSP is particularly suitable for the characterization of proteins and nanoparticles where high sensitivity for size and zeta potential measurement is required. It includes a Protein Measurement option for protein mobility measurements.

The system incorporates a two angle particle and molecular size analyzer for the enhanced detection of aggregates and measurement of small or dilute samples, and samples at very low or high concentration using dynamic light scattering with ‘NIBS’ optics. The ZSP also incorporates a zeta potential analyzer that uses electrophoretic light scattering for particles, molecules and surfaces, and a molecular weight analyzer using static light scattering.

Using Non-Invasive Backscatter optics (NIBS) it has significantly better performance than systems using 90 degree scattering optics.

In addition, a microrheology option is available for measuring sample viscosity and viscoelastic properties.

The flow mode option enables the system to be connected to an SEC or an FFF system to use as a detector for the size of proteins or nanoparticles.

A choice of cuvettes is available, from disposable single-use to specific cells for viscous or high concentration samples or measuring the zeta potential of surfaces.

Parameters measured:
Particle and molecule size, translational diffusion, electrophoretic mobility, zeta potential of particles at high and low concentrations, viscosity and viscoelasticity of protein and polymer solutions, concentration, MW, A2, kD.

An optional accessory enables measurement of the zeta potential of solid surfaces.

  • Exceptional sensitivity for the zeta potential measurement of proteins and nanoparticles using patented M3-PALS.
  • Size measurement from 0.3nm (diameter) to 10 microns using patented NIBS (Non-Invasive Back Scatter) technology.
  • Zeta potential of surfaces using accessory cell.
  • Molecular weight measurement down to 980Da.
  • Microrheology option to measure viscosity and viscoelasticity.
  • Outstanding protein size measurement sensitivity, 0.1mg/mL (Lysozyme).
  • Sample concentrations from 0.1ppm to 40%w/v.
  • Built-in protein calculators, including protein charge, A2, kD, and molecular conformation.
  • A ‘Quality Factor’ and ‘Expert Advice System’ gives the confidence of having an expert at your shoulder.
  • 21CFR part 11 software option to enable compliance with ER/ES.
  • Research software option to give access to further features and analysis algorithms for the light scattering specialist.
  • Automation of measurements using an autotitrator option.
  • Chromatography detector capability to enable use as a size detector with GPC / SEC or FFF.
  • Optical filter option to improve measurements with fluorescent samples.

The Zetasizer Nano ZSP incorporates three techniques in a single compact unit, and has a range of options and accessories to optimize and simplify the measurement of different sample types.

Dynamic Light Scattering is used to measure particle and molecule size. DLS measures the diffusion of particles moving under Brownian motion, and converts this to size and a size distribution using the Stokes-Einstein relationship. Non-Invasive Back Scatter technology (NIBS) is incorporated to give the highest sensitivity simultaneously with the highest size and concentration range.

Measurement of size as a function of concentration enables the calculation of kD, the DLS interaction parameter.

The Microrheology option uses the DLS measurement of tracer particles to probe the structure of dilute polymer and protein solutions.

Laser Doppler Micro-electrophoresis is used to measure zeta potential. An electric field is applied to a solution of molecules or a dispersion of particles, which then move with a velocity related to their zeta potential. This velocity is measured using a patented laser interferometric technique called M3-PALS (Phase analysis Light Scattering). This enables the calculation of electrophoretic mobility and from this the zeta potential and zeta potential distribution.

A surface zeta potential accessory uses tracer particles to measure electro-osmosis close to a sample surface to calculate the zeta potential of the surface.

Static Light Scattering is used to determine the molecular weight of proteins and polymers. The scattering intensity of a number of concentrations of the sample is measured, and used to construct a Debye plot. From this the weight average molecular weight and second virial coefficient can be calculated, which provides a measure of protein solubility.

This technique is very demanding on the sensitivity and stability of the whole system, and requires that every element of the design is optimized to ensure accuracy and repeatability.

Software
The software is designed to be versatile and rich in features without compromising ease of use. Standard Operating Procedures (SOP) simplify routine measurements, a quality factor gives a single place for confirmation of data quality, and an expert advice system is provided to assist with data interpretation.

Options
The MPT-2 Autotitrator enables the study of the effect of changes in pH, conductivity, or any additive to be automated.

A range of disposable and reusable cells are available to optimize the measurement in terms of sample volume, concentration and flow measurement.

Other options include filters to improve the measurement of fluorescent samples and a viscometer to determine the sample viscosity to the accuracy required for the techniques used.

Particle size and molecular size

Measurement range:
0.3nm – 10.0 microns* (diameter)
Measurement principle:
Dynamic Light Scattering
Minimum sample volume:
12µL
Accuracy:
Better than +/-2% on NIST traceable latex standards
Precision / Repeatability:
Better than +/-2% on NIST traceable latex standards
Sensitivity:
0.1mg/mL (Lysozyme)

Zeta potential and Protein Mobility

Measurement range:
3.8nm – 100 microns (diameter)*
Measurement principle:
Electrophoretic Light Scattering
Minimum sample volume:
150µL (20µL using diffusion barrier method)
Accuracy:
0.12µm.cm/V.s for aqueous systems using NIST SRM1980 standard reference material
Sensitivity:
1mg/mL (Lysozyme)

Molecular weight

Measurement range:
980Da – 20M Da*
Measurement principle:
Static Light Scattering using Debye plot
Minimum sample volume:
12µL (3-5 sample concentrations required)
Accuracy:
+/- 10% typical

Microrheology (option)

Measurement principle:
Dynamic Light Scattering
Minimum sample volume:
12µL (DLS measurement only)

General

Temperature control range:
0°C - 90°C +/-0.1**
Light source:
He-Ne laser 633nm, Max 10mW
Laser safety:
Class 1
Power:
100VA
Dimensions (W, D, H):
320mm, 600mm, 260mm
Weight:
19kg

Operating environment

Temperature:
10°C – 35°C
Humidity:
35% - 80% non-condensing

Notes

*:
maximum range, sample dependent
**:
at 25ºC
Patents:
The Zetasizer Nano range is protected by the following patents: Non-Invasive Back Scatter (NIBS) EP884580, US6016195, JP11051843 High and Low Frequency Electrophoreses (M3) EP1154266, US7217350, JP04727064 Light Scattering Measurements using Simultaneous Detection EP2235501, CN102066901, JP2011523451, US20090251696 Surface Potential Determination in a Dip Cell WO2012172330
A range of accessories are available to make life easier, or to add capability to the system

Zetasizer Nano ZSP

Accessories

NanoSampler

Image

Automated particle size measurement for the Zetasizer Nano

The Zetasizer NanoSampler is a sample delivery system that ensures highly precise and reproducible automated loading of samples into your Zetasizer Nano. The NanoSampler adds automation and unattended operation in a versatile, compact package, maximising the productivity of your Zetasizer Nano. While the benefits of automated operation are useful for all users, the NanoSampler is ideally suited for laboratories where a large number of measurements are required and reproducibility or multi-variate studies are important.

More information

MPT-2

Image

Simplify pH, conductivity and additive titrations on your Zetasizer Nano

A cost effective accessory designed to automate the measurement of size and zeta potential as a function of pH, conductivity or any soluble additive.

More information

SV-10 viscometer

Image

Viscosity measurement with speed, simplicity and accuracy.

The SV-10 measures viscosity with the accuracy required for dynamic light scattering, for the conversion of diffusion speed to size, and electrophoretic mobility to zeta potential, in an extremely simple and rapid system.

More information

Cell and cuvette options

Disposable folded capillary cell (DTS1070)

Image

Eliminate sample cross contamination between zeta potential measurements using a completely disposable cell.

The zeta potential of colloids and molecules is extremely sensitive to contamination from components of a previous sample used in a measurement cell. The use of a disposable cell completely eliminates this potential contamination issue.

The folded capillary cell provides the benefits of the accuracy of measurement of a capillary cell with the ease of use of a disposable cell.

Although, disposable, including the electrodes, for low conductivity samples each cell can be used for hundreds of measurements if required.

The cell can be used with the autotitrator, where multiple measurements are routinely done over a wide pH range.

Visit store to buy now

Universal 'dip' cell kit

Image

Reusable solvent resistant cell.

The dip cell is used for the measurement of zeta potential of samples in aqueous and non-aqueous dispersants, and is designed to be cleaned and reused. It is for batch measurements using standard polystyrene or glass cuvettes.
Visit store to buy now

High concentration zeta potential cell kit

Image

Save time and effort by measuring zeta potential with little or no dilution.

The high concentration cell enables the measurement of the zeta potential of samples with little or no dilution in any Zetasizer Nano system that measures zeta potential.

The cell has a flow configuration so can be used for stop-flow size and zeta potential measurements using an MPT-2 autotitrator as well as batch measurements.

Visit store to buy now

Surface zeta potential accessory

Image

Extend the application of the Zetasizer Nano to measure the zeta potential of material surfaces.

The characterization of surfaces and interfaces is critical in a wide range of industries including consumer products, specialty chemicals, pharmaceuticals and life sciences. In each of these application areas, the interaction of molecules and particles with surfaces can influence the material properties of the end product.

The surface zeta potential accessory enables the measurement of the zeta potential of flat surfaces such as filter paper, silica, polymers and bone, using a standard Zetasizer Nano system.

Visit store to buy now

Quartz flow cell (ZEN0023)

Add flow capability for size measurements to the Zetasizer.

  • Measure size and intensity with MPT-2 autotitrator.
  • Connect to an SEC system to use as a DLS detector.
Visit store to buy now

12mm Glass cell (PCS1115)

Glass cuvette for use with the dip cell.

  • For size and zeta potential measurements using the ‘dip’ cell.
  • Compatible with aqueous and non-aqueous solvents and dispersants.
Visit store to buy now

12mm Square Polystyrene Cuvettes (DTS0012)

Disposable polystyrene cuvettes.

  • 100 disposable cells complete with 100 stoppers to avoid cross contamination.
  • For size measurements using aqueous dispersants.
  • Compatible with zeta potential measurements using the dip cell.
Visit store to buy now

12mm square glass cell (PCS8501)

Glass cuvette for batch measurements.

  • For size and molecular weight measurements.
  • Compatible with aqueous and non-aqueous solvents and dispersants.
Visit store to buy now

Disposable Solvent Resistant Micro Cuvette (ZEN0040)

Disposable plastic micro cuvette, for size measurement at 173° (NIBS) optics only.

  • 100 x 40µL cuvettes with 100 caps to avoid cross contamination.
  • Compatible with aqueous samples and a range of other solvents: Acetone, Benzaldehyde, Butanone, Dioxane, DMF, Ethyl acetate, Isopropanol, plus various acids and bases.
Visit store to buy now

Low-volume quartz batch cuvette (ZEN2112)

Low-volume quartz batch cuvette for size and molecular weight measurements.

  • Compatible with size and molecular weight measurements with aqueous and non-aqueous solvents and dispersants.
  • Minimum sample volume 12 microliters.
  • Maximum volume 45 microliters.
Visit store to buy now

ZEN0118

Disposable low volume cuvette for size measurement with 90° optics only.

  • 100 x 50µL cuvettes with 100 caps to avoid cross contamination.
  • Compatible with aqueous dispersants.
Visit store to buy now

Factory fitted options

Narrow band filters

Useful where the sample fluoresces. Eliminates scattering due to fluorescence to improve the signal to background ratio.

Degasser for MPT-2 autotitrator

Titrants used by the MPT-2 titrator need regular degassing, ideally before each titration.

Degassing is required to remove bubbles that can affect the volume of titrant dispensed. This is particularly important close to pH 7 where low volumes of titrant are required.

The degasser is a highly recommended ‘Fit and forget’ accessory that continuously degasses titrants which improves the speed of titrations and the accuracy of reaching the target pH. This gives more evenly spaced pH points.

Visit store to buy now

Protect your investment and ensure optimized performance at all times with Malvern Panalytical’s service plans.

When you purchase a Malvern Panalytical product we understand that this is just the first stage of a working relationship that will last for the lifetime of the instrument. Depending on your needs, Malvern Panalytical will provide the support for your business.

Help Desk

Training

Software downloads

Malvern Panalytical’s service options- choose the right plan for you:

Malvern Panalytical Platinum Plan

For laboratories where maximizing instrument up-time is critical to its daily performance. Our highest level of response and the 'all inclusive' price plan takes care of those unexpected repair bills should the unfortunate occur.

Malvern Panalytical Gold Plan

Enhance your laboratory productivity by maintaining instrument efficiency. Still receive that priority response, combined with specialist technical and software support, we'll keep your instrument performance on track to deliver.

Malvern Panalytical Bronze Visit

For laboratories looking to optimize instrument performance, regular preventative maintenance is essential.

Platinum PlanGold PlanBronze Visit
Annual PM/PV Test
yes
yes
no
Telephone / Email Support
yes
yes
no
Priority Response
yes
yes
no
Emergency Breakdown visits*
yes
yes
no
Parts Included
yes
no
no
E-Learning**
yes
yes
no
Technical & Software Support
yes
yes
yes
IQ/OQ (Pharma)***
yes
yes
yes

*including labour & travel costs** Platinum 2 places per contract term, Gold 1 place per contract term***available at an additional cost