The Petro edition of the Zetium spectrometer is pre-configured to deliver compliant results from day 1 with the appropriate hardware and your choice of compliance modules, which include factory pre-calibration according to ASTM and ISO international test methods. 

Inclusion of the innovative ED core, makes it the only XRF spectrometer capable of satisfying both WDXRF and EDXRF test methods using a single instrument. Inclusion of the innovative ED core not only delivers dual-compliance but can be used to detect unexpected elements in production samples with simultaneous spectrum acquisition.

Design features for compliance

  • The 1 kW SST-R Rh tube delivers exceptional performance for the majority of applications (upgrades to 2.4, 3 and 4 kW available)
  • User-friendly software with integrated intelligence for novice and advanced users
  • Small sample load port volume minimizes helium consumption
  • Automatic sample recognition and vacuum-helium switching
  • Liquid cup construction tools for simple sample preparation
Design features for compliance

Advanced software and unique application solutions

  • The latest version of our renowned SuperQ software features a new, streamlined user interface, advanced matrix correction algorithms, such as multi-scatter fluorescence, integration of ED deconvolution and integrated intelligence with the Virtual Analyst
  • Guarenteed compliance at start-up with factory pre-calibrated Compliance Modules: 
  • - S in mineral oil (ASTM D2622) 
  • - S in diesel (ASTM D2622) 
  • - S in gasoline (ASTM D2622) 
  • - Additives in lubrication oils (ASTM D6443)
  • Oil Trace eliminates mass/volume dependance and allows different types of petrochemicals to be measured against a single calibration, eliminating the cost of calibration samples and the time required to maintain multiple calibrations
Advanced software and unique application solutions

Upgrade packages to meet every challenge

The modular design of the Zetium platform allows optimization of the Petro edition through the addition of upgrade packages that deliver tangible benefits:

  • SumXcore - for reduction in analysis times and identification of unexpected elements in production samples
  • Small Spot Mapping - ideal for the analysis of inorganic inclusions (catalysts, additives, etc.) for process troubleshooting
  • Speed & throughput - for faster sample analysis
  • Robustness & uptime - for tough environments
  • Flexibility - to accomodate sample size variations
  • Performance enhancement - for superior sensitivity
Upgrade packages to meet every challenge
Basic configuration highlightsConfiguration upgradesBenefits
One application of choice between: Guaranteed fuel compliance S in fuels and oils (ASTM D2622)
Guaranteed lube oil compliance (ASTM D6443)
Additional applications of choiceGuaranteed compliance at start-up with factory pre-calibrated compliance modules:
• S in mineral oil (ASTM D2622)
• S in diesel (ASTM D2622)
• S in gasoline (ASTM D2622)
• Additives in lubrication oils (ASTM D6443)
Oil-TraceEliminates mass/volume dependence and allows different types of petrochemicals to be measured against a single calibration, eliminating the cost of calibration samples and the time required to maintain multiple calibrations
SST R 1 kW X-ray tubeMaximum uptime with minimum monitor correction
3 or 4 kW X-ray tubeFaster results and lower detection limits in the same measurement time
Curved crystals for faster resultsUp to 30% more intensity in the same measurement time
Shorter measurement time to achieve required limits
Duplex detectorImproved ‘catalyst killer’ elements detection, like nickel, iron and vanadium
SumXcoreFaster results in tandem with the WD functionality
Detect unexpected changes in composition
Small spot mappingUnique compositional mapping with the ED core, for fast and accurate investigation of pipe scaling and other defects

Services

Solutions to maximize the return on your investment

To assure that your instrument remains in top condition and performs on the highest level, Malvern Panalytical offers a wide range of services. Our expertise and support services assure an optimal functioning of your instrument.

Support

Service for a lifetime

  • Phone and remote support
  • Preventive maintenance and checkups
  • Flexible Customer Care Agreements
  • Performance certificates
  • Hardware and software upgrades
  • Local and global support

Expertise

Adding value to your processes 

  • Sample preparation development/optimization
  • Analytical methodologies 
  • Turnkey solutions for XRD 
  • Operations via IQ/OQ/PQ, quality assurance (GLP, ISO17025) or round robins/inter laboratory studies
  • Automation of lab processes
  • Consultancy services

Training and education

  • Training on-site or at our competence centers
  • Broad range of basic and advanced courses on products, applications and software

Analytical services and calibration materials

  • Expert (XRF) analyses services
  • Oxides and trace analysis
  • Customized calibration materials