Reference Materials

We offer a wide range of reference materials and standards to cover XRF, particle size, zeta potential and molecular weight. These are available as easy to use out of the box solutions with industry specific application templates.

Fused Borate Discs 

Calibration made easy!

Customized Fused Borate Disks for the Calibration and Monitoring of XRF Applications

Claisse® has a new turn-key solution for your XRF applications. Our fused borate disks are made with Certified Reference Materials (CRM) or customized mixtures of synthetic oxides. They are custom-made to fulfill your personal analytical needs.

Fused borate disks:

  • Help you build the best XRF calibration curves for your application
  • Offer a great alternative to a XRF drift monitor when a more specific element needs to be monitored
  • Can replace silica based drift monitors when unavailable

Five Reasons for Using Claisse® Fused Borate Disks

  1. High Quality Disk Preparation: As the First and Finest in Fusion, Claisse® produces borate disks that exceed the industry's quality standards. From this high accuracy and precision of the fusion borate disks, build your XRF application calibration curves so as to obtain accurate results for your samples.
  2. Time Saving: Claisse® will save you enormous time by finding the appropriate CRM for your calibration needs and preparing fused disks for you.
  3. Quick Application Start-Up: With your fused disks already prepared for the calibration curve, you can integrate the new application rapidly in your day-to-day routine and start analyzing your samples right away.
  4. Low Cost: The cost of a fused disk is less than 50% of the cost of CRMs when bought as a powder.
  5. Diversity: Claisse® can produce almost any mix of oxides, extending the calibration possibilities.
    For synthetic standards, we can perform the tedious task of preparing the mixes to cover the calibration range needed for the elements, while making sure the homogeneity is perfect.

Here are a few examples of our available products

  • PbZn calibration (25 disks) with synthetic oxide
  • NIST srm 1880 to 1889
  • JCA cement standard kit (JCA 601a XRF1 to XRF15)
  • Cement and raw material calibration curves (21 disks)
  • Iron Ore Exploration (28 disks)

CEMOXI – Oxide analysis of cement by XRF 

The success of any application is dependent on the quality of the calibration standards used. Finding high quality standards in the required analytical range is not only challenging but in most cases extremely expensive. Making synthetic standards is a viable solution but requires significant expertise and time. 

Cemoxi1.jpg

Malvern Panalytical offers CEMOXI, which is a set of synthetic standards, together with an application setup for the Zetium spectrometer as a simple solution. The standards enable calibrations for thirteen major elements in the analysis of oxide materials based on fused beads. The CEMOXI standards set is suited for a wide variety of cement materials and the raw materials used in its manufacture, including: limestones iron ore, clay/shales and gypsum. 

A tailored alternative to ideal concentrations

CEMOXI can be used either as a primary fused bead calibration or to verify in-house standards for pressed powder applications (using fusion). Since the use of CRM’s are limited to material available and are expensive, synthetic standards such as CEMOXI offer concentrations and analytical ranges that are tailored while remaining cost effective. The CEMOXI standards have been validated using 25 CRM’s and show excellent agreement.

  • Full traceability
  • Flexible sample preparation options
  • Adaptable to include additional material of specific interest
  • Cost effective solutions

Cemoxi2.jpg

Which materials can be analyzed?

  • Portland cement
  • High alumina cement
  • Raw meal
  • Limestones
  • Dolomitic limestones
  • Gypsum
  • Clay/shales
  • Fly ash

Cemoxi3.jpg

Why Fusion?

The standards are fused to remove:

  • Mineralogical effects
  • Particle size effects

Fused samples are ‘perfect’ samples, and in combination with the Fundamental Parameters (FP) matrix correction model enable very wide concentration ranges in a single calibration.

Fusion is ideal for excellent light element analysis. 

Cemoxi4.jpg

The CEMOXI standards set is comprised of 9 multi element synthetic cement standards (including pure gypsum) supplied as powders to be prepared as fused beads. Standards are supplied as 10g powders in air tight plastic bottles, packed under nitrogen. The full set is housed in an aluminum carrying case containing the standards, user information and concentrations on CD ROM.

Fused beads are prepared using recipes provided and pre-programmed on the Eagon 2 or using one’s own. Calibrations are created using provided templates in SuperQ which can be adapted and/or extended.

Standards are made from pure chemicals, pre-conditioned, weighed, ground and then ignited at 10500C before packaging under nitrogen. Detailed instructions on the use and handling of the CEMOXI standards are included with the application package.

The included compounds and analytical ranges are shown below:

Elements  Concentration range (wt%)

Na2O  0-1.0  

MgO  0-6.0  

Al2O3 0-10  

SiO2  0-24  

P2O5  0-0.5  

SO3  0-59  

K2O  0-2.0  

CaO (0)-70  

TiO2  0-1.0  

Mn2O3  0-0.29  

Fe2O3  0-7.0 

ZnO  0-0.25  

SrO  0-0.7 

The CEMOXI standards set is suited for a wide variety of cement materials and the raw materials used in its manufacture, including: limestones iron ore, clay/shales and gypsum. 

WROXI

Accurate wide-range oxide analysis of minerals

The success of any application is dependent on the quality of the calibration standards used. Finding high quality standards in the required analytical range is not only challenging but in most cases extremely expensive. Making synthetic standards is a viable solution but requires significant expertise and time.

Wroxi1.jpg

Malvern Panalytical offers WROXI, which is a set of synthetic standards, together with an application setup for the Zetium XRF spectrometer as a simple solution. The standards enable calibrations for twenty-one major elements in the analysis of oxide materials based on fused beads. These cover a wide range of geological material compositions. The WROXI standards set is suited for a wide variety of materials, including: silicates, carbonates, phosphates, rocks, soils, iron ores, manganese ores, cements. 

  • Simple sample preparation
  • High accuracy and precision
  • Good to excellent detection limits

Primary and/or validation calibration 


WROXI can be used either as a primary fused bead calibration or to verify in-house standards for pressed powder applications (using fusion). Since the use of CRM’s are limited to material available and are expensive, synthetic standards such as WROXI offer concentrations and analytical ranges that are tailored while remaining cost effective. The WROXI calibration has been validated with over 115 CRM’s and shows excellent agreement. 

  • Full traceability
  • Flexible sample preparation options
  • Adaptable to include additional material of specific interest

Wroxi2.jpg

Which materials can be analyzed? 

  • Limestone
  • Iron/manganese ore
  • Bauxite
  • Clay/shales
  • Rocks
  • Phosphates
  • Feldspar
  • Blast furnace slags
  • Fly ash
  • Gypsum
  • Soils

Wroxi3.jpg

Why Fusion? 

The standards are fused to remove: 

  • Mineralogical effects
  • Particle size effects

Wroxi4.jpg

Fused samples are ‘perfect’ samples, and in combination with the Fundamental Parameters (FP) matrix correction model enable very wide concentration ranges in a single calibration. 

Fusion is ideal for excellent light element analysis

Synthetic multiple oxides standards

The WROXI standards set is comprised of 20 synthetic multiple oxides standards supplied as powders to be prepared as fused beads. Standards are supplied as 5g powders in air tight plastic bottles, packed under nitrogen. The full set is housed in an aluminum carrying case containing the standards, user information and concentrations on CD ROM.

Wroxi1.jpg

Preparation

Standards are made from pure chemicals, pre-conditioned, weighed, ground and packaged under nitrogen. Detailed instructions on the use and handling of the WROXI standards are included with the application package.

Fused beads are prepared using recipes provided and preprogrammed on the Eagon 2 or using one’s own. Calibrations are created using provided templates in SuperQ which can be adapted and/or extended.

Elements and analytical ranges

The WROXI calibration standards include 21 elements with a wide concentration range covering many materials. The elements and analytical ranges are shown in the figure.

Wroxi5.jpg

The WROXI module and standards are ideal for calibrating the Zetium spectrometer for a wide variety of geological materials, ores and minerals. 

Wroxi6.jpg

NiFeCo-FP

Accurate elemental analysis of NiFeCo alloys

Special steels, high-temperature alloys and superalloys are used in a wide variety of high-performance components for their characteristics such as durability, hardness, temperature stability and corrosion resistance. The production of high-specification steels requires process and quality control with very strict tolerances. The challenges of analyzing a large variety of alloying elements with wide ranges of concentrations by XRF are well known to the metals industry. In particular, the matrix corrections needed and the large number of reference materials required for high-quality results are generally a concern. 

Nifeco1.jpg

The Metals edition of Zetium with NiFeCo-FP is the solution to these challenges. Malvern Panalytical’s Fundamental Parameter (FP) matrix correction algorithm is used to provide a single application program for wide-range alloys analysis of up to 21 elements.

NiFeCo-FP module for the Zetium spectrometer 

Nifeco2.jpg

NiFeCo-FP module comes with a suite of carefully selected setup samples and a SuperQ application template for fast application deployment. With the NiFeCo-FP module a wide range of Ni-, Co- and Fe-based alloys, super alloys and steels can be analyzed with a very high accuracy and precision:

  • Stainless steel
  • High speed steel
  • Low alloy steel
  • Tool steel
  • Mild steel
  • Nimonic steels
  • Inconel
  • High Mn steel
  • Ni alloy

Malvern Panalytical’s Fundamental Parameter (FP) model 

Malvern Panalytical’s FP algorithm used in the SuperQ software calculates matrix corrections from the theoretical laws governing the physics of X-rays. As such, FP models have a significant advantage over more traditional influence coefficient-based matrix corrections (e.g. theoretical alphas). 

Unlike theoretical alphas calculations, the FP model calculates matrix corrections that are specific to each sample. This enables accurate analyses over very wide ranges in concentration and in very different types of sample. In addition, accurate analysis can be made outside the range of concentrations bracketed by the standards. 

Nifeco3.jpg

NiFeCo-FP module 

The NiFeCo-FP module comprises of: 

  • A suitcase for safe storage 
  • 6 calibration setup samples, traceable to more than 120 CRMs
  • 2 drift monitor samples

The elements and ranges (wt %) included in the reference samples, are:

Elements     Concentration range (wt%)         Elements                 Concentration range (wt%)

Al                     0.01 - 6                             Cu                     0.01 - 30

Si                     0.01 - 2.4                             Y                             0.01 - 0.3

P                     0.01 - 0.3                             Zr                             0.01 - 0.4

S                     0.01 - 0.1                             Nb                     0.01 - 6.3

Ti                     0.01 - 4                             Mo                     0.01 - 21

V                     0.01 - 3                             Hf                             0.01 - 1.3

Cr                     0.01 - 24                             Ta                             0.01 - 7.2

Mn                     0.01 - 15                             W                             0.01 - 15

Fe                     0.01 - 78                             Re                     0.01 - 5.4

Co                     0.01 - 63                             Pt                             0.01 - 0.3

Ni                     0.01 - 64

The NiFeCo module and setup samples are ideal for calibrating the Zetium spectrometer for the analysis of high temperature steels and super alloys

Nifeco5.jpg

Cu-base-FP 

Accurate elemental analysis of Cu metals

‘Copper-base’ (Cu-base) is a term used to describe a range of alloys where Cu is the principal component. In order to make the materials suitable for different applications (e.g. the manufacture of coinage, bells, a wide range of mechanical equipment and electrical wiring), Cu is normally alloyed with elements such as Sn, Zn, Ni, Al, and Pb. During the production process fast chemical analysis is needed to minimize errors in production and to maximize production yield. The Cu-base-FP package (including applicable calibration standards) covers the analysis of this wide range of Cu alloys by using Malvern Panalytical’s Fundamental Parameter (FP) model.

CuBase1.jpg

Cu-base-FP module for the Zetium spectrometer 

Cu-base-FP module comes with a suite of carefully selected certified reference samples and a SuperQ application template for fast application deployment. The module allows very accurate and precise analysis of a wide range of Cu-based materials: 

  • Bronze 
  • Aluminum bronze
  • Phosphor bronze
  • Leaded bronze
  • Brass
  • Alloyed brass
  • Leaded brass

CuBase2.jpg

Malvern Panalytical’s Fundamental Parameter (FP) model 

Malvern Panalytical’s FP algorithm used in the SuperQ software calculates matrix corrections from the theoretical laws governing the physics of X-rays. As such, FP models have a significant advantage over more traditional influence coefficient-based matrix corrections (e.g. theoretical alphas). 

Unlike theoretical alphas calculations, the FP model calculates matrix corrections that are specific to each sample. This enables accurate analyses over very wide ranges in concentration and in very different types of sample. In addition, accurate analysis can be made outside the range of concentrations bracketed by the standards.

CuBase3.jpg

Cu-base-FP module 

The Cu-base module comprises of: 

  • A suitcase for safe storage
  • 23 carefully selected certified reference samples
  • 2 drift monitor samples

CuBase4.jpg

The elements and ranges (wt %) included in the reference samples, are:  

Elements Concentration range (wt%) Elements Concentration range (wt%)

Mg Below LLD – 0.3 Ni 0.007 – 33 

Al Below LLD – 13 Cu 54.4 – 96 

Si Below LLD – 0.6 Zn 0.013 – 43 

P 0.001 – 1.0 As Below LLD – 0.3 

S 0.0013 – 0.14 Sn 0.006 – 17 

Cr 0.0013 – 1.0 Sb 0.005 – 0.5 

Mn Below LLD – 2.3 Pb 0.005 – 21 

Fe 0.003 – 5.6 Bi Below LLD - 2 

Co 0.012 – 0.3

NOTE: Below LLD means the certified concentration is lower than the Lower Limit of Detection 

Low alloy steel analysis with Malvern Panalytical XRF spectrometers

Excel your analysis with Malvern Panalytical’s pre-calibrated solutions

Low_AlloySteel1.jpg

Low alloy steels are widely used for the production of pipes, automotive and aerospace bodies, railway lines and offshore and onshore structural engineering plates. High-strength low alloy steel is used in these areas due to its corrosion resistance properties. Low alloy steels tipically contain less than 10% alloying elements (C, Mn, Cr, Ni, Mo, V and Si combined). Accurate and fast elemental analysis is a critical requirement during the production of steel. It is not only required for compliance with quality standards, but it also enables the steel producer to save costs in an increasingly competitive environment.

To address the needs of the steel making industry with regard to speed and flexibility in analysis, Malvern Panalytical X-ray sequential and simultaneous spectrometers Zetium and Axios FAST can be delivered pre-calibrated with a low alloy steel (LAS) package. The pre-calibrated solution is based on more than 90 certified reference materials (CRMs) covering for a wide elemental range of up to 21 elements and four monitor samples for drift- and sample preparation correction.

LAS pre-calibration for Zetium and Axios FAST spectrometers 

The low alloy steel (LAS) calibration has been setup using more than 90 certified reference materials sourced from several suppliers. To pre-calibrate Zetium and Axios FAST spectrometers, this master calibration is transferred using six CRMs using the SuperQ Calibration update.

Low_AlloySteel2.jpg

Hi-Per channels – for higher sensitivities and quicker analysis 

Zetium and Axios FAST can be fitted with either one or two Hi-Per channels for increased sensitivity for elements from boron to magnesium. Hi-Per channels use curved, multi-layer crystals to focus incoming radiation. This results in a short optical path length, delivering intensities significantly higher than conventional channels. 

Low_AlloySteel3.jpg

Low alloy steel analysis 

The low alloy steel (LAS) calibration package can be calibrated on 2.4, 3 or 4 kW, and is retrofittable.

The low alloy steel (LAS) package comprises of: 

  • A suitcase for safe storage
  • 4 monitor samples for drift monitor and sample preparation correction
  • Traceability documents

Low_AlloySteel1.jpg

Elements and their concentration ranges covered by low alloy steel application (LAS) on a Zetium or Axios FAST sequential and simultaneous spectrometers (wt%):


 

Element

 

Concentration range (wt%)

 

  Element

 

Concentration range (wt%)

C

<LOQ - 1.29

Cu

0.0013 - 0.66

Al

<LOQ - 0.3

As

0.0005 - 0.14

SI

<LOQ - 1.46

Zr

0.0015 - 0.2

P

0.002 - 0.072

Nb

0.0004 - 0.3

S

0.0009 - 0.089

Mo

0.002 - 1

Ti

0.0005 - 0.31

Sn

0.001 - 0.24

V

0.0006 - 0.52

Sb

0.0005 - 0.072

Cr

0.0015 - 5.15

Ta

0.001 - 0.23

Mn

0.0057 - 2

W

0.012 - 0.3

Co

0.0012 - 0.3

Pb

<LOQ - 0.024

Ni

0.002 - 4.45

 Low alloy steel analysis 

The low alloy steel (LAS) pre-calibration package is ideal for the analysis of: 

  • high-strenght low alloys
  • high heat resistance steels (Chromium-Molybdenum steel),
  • low temperature use steels (Nickel steels)
  • weathering steels and high yield
  • high tensile strength steels.

Low_AlloySteel4.jpg

Pro-Trace calibration setup samples 

Major cost savings for laboratories 

One of the key features of Pro-Trace is the use of specially prepared blank specimens and calibration setup samples. These setup samples are calibrated against more than 200 international certified reference materials, providing major cost savings for laboratories that do not have such an extensive library of standards in-house. The Pro-Trace setup samples are manufactured in Malvern Panalytical’s Nottingham facility. 

ProTrace.png

Out of the box solution for the analysis of rocks, soils, coals... 

The standards are a cleverly designed set, covering wide ranges of element selection and concentration. They are prepared to very high specifications using ultra-pure compounds that are traceable. Mounted in aluminium rings for longevity, and housed in aluminium cups to prevent contamination, the standards represent real value for money.

Oil-Trace calibration setup samples 

Compliancy with international norms 

Oil-Trace is particularly useful for the analysis of fuels, biofuels and mixtures. For example B20, E5, E85, additives in lubricating oils and wear metals in used oils, S, Ni, V and other restricted elements in crude oils and further, refined oils, chlorine in compressor oils, metals in homogeneous liquid catalysts and troubleshooting for catalyst poisoning. 

In addition, Oil-Trace fully supports compliancy with international ASTM and ISO norms and methods. 

OilTrace.png

Reduce the need for different reference materials 

The Oil-Trace unique suite of standards is used to set up a base-line calibration based on Malvern Panalytical's 5th generation FP model and reduces the need for many different reference materials. 

ADPOL

Accurate elemental analysis by XRF of functional polymer additives


As properties of polymers are greatly enhanced and tuned to applications by incorporation of functional additives, control of the production process is crucial. Also the use of these additives has to comply to several environmental regulations and standards. 

Accurate elemental analysis using ADPOL calibration standards can save you money and supports your compliance to international regulations like REACH.


ADPOL.jpg

ADPOL for additives and fillers in polymers 

The ADPOL module enables easy and accurate elemental analysis of common additive and filler elements. Assisted by ready to use application templates, little effort is needed for optimal system set-up. Your benefit is accurate and trustworthy elemental composition of your polymers, compounds and plastics realized in minutes. 

Moreover ADPOL is manufactured in close cooperation with DSM Resolve, an industry leader in polymer analysis and close relations with world leading polymer manufacturers. 

ADPOL2.jpg

A unique calibration module

  • Synthetic polymeric calibration standards containing elements representing commonly used functional additives
  • Relevant concentration ranges for many polyethylene and polypropylene types and grades
  • Reference Materials analyzed by multiple analytical techniques 
  • SuperQ application templates for fast application deployment incorporating years of XRF experience resulting in optimal accuracy and analysis time 
  • Available for Zetium and the range of Epsilon XRF spectrometers

ADPOL3.jpg


ADPOL 


The ADPOL module comprises of: 

  • ADPOL, Malvern Panalytical A suitcase for safe storage
  • Four standards and a blank (4 replicates of each) in pressed discs with excellent surface flatness for reproducible light element calibrations
  • Uniquely numbered certificate and documentation
  • CD containing application templates for SuperQ and relevant documentation

ADPOL.jpg


The standards consist of PE discs containing the following elements and concentration ranges: 

 

Elements

 

Concentration range (mg/kg)

F

Below 5 - 266

Na

Below 0.5 - 189

Mg

Below 1 - 561

Al

Below 0.5 - 385

Si

Below 10 - 778

P

Below 5 - 94

S

Below 5 - 98

Ca

Below 0.5 - 200

Ti

Below 0.5 - 112

Zn

Below 0.5 - 198 

ADPOL 

The ADPOL module and calibration standards are ideal for calibrating Zetium and Epsilon spectrometers for many polyethylene and polypropylene types and grades

ADPOL4.jpg

TOXEL

Accurate analysis by XRF of toxic elements in polymers and plastics

As toxicity of incorporated functional additives are of great concern directly for human health and the environment, accurate low level determination of these elements is crucial. Our Zetium or Epsilon 3X spectrometers combined with the TOXEL module offers you the best solution available for screening and elemental analysis of toxic elements in polymers and plastics.

Accurate elemental analysis using TOXEL calibration standards supports your compliance to international regulations like REACH, RoHS 2, WEEE, ELV, packaging directives and others.

Toxel1.jpg

TOXEL for toxic elements in polymers 

The TOXEL module enables easy and accurate elemental analysis of toxic elements. Assisted by ready to use application templates, little effort is needed for optimal system set-up. Your benefit is accurate and trustworthy elemental analysis of your polymers, compounds and plastics realized in minutes. 

Moreover TOXEL is manufactured in close cooperation with DSM Resolve, an industry leader in polymer analysis and close relations with world leading polymer manufacturers. 

Toxel2.jpg

TOXEL: A unique calibration module

  • Synthetic polymeric calibration standards containing elements representing commonly regarded toxic or suspect toxic compounds
  • Ideal for functional additives like flame retardants and pigments or catalysts residues.
  • Relevant concentration ranges for many polyethylene and polypropylene types and grades
  • Reference Materials analyzed by multiple analytical techniques
  • Application templates are available for fast application deployment. These templates incorporate years of XRF experience resulting in optimal accuracy and analysis time 

Toxel3.jpg

The TOXEL module and calibration standards are ideal for calibrating Zetium and Epsilon XRF spectrometers for many polyethylene and polypropylene types and grades. 

Toxel4.jpg

RoHS WEEE Calibration Standards – elemental analysis of RoHS restricted materials 

Accurate elemental analysis of RoHS restricted materials


RoHS Calibration Standards aid manufacturers and research laboratories comply with requirements of RoHS 2 legislation. Developed in co-operation with DSM Resolve, they provide the accurate calibration required for precise determination of product compliance using X-ray fluorescence (XRF) spectrometry. Accurate elemental analysis using RoHS Calibration Standards can save you money and supports your compliance to international regulations like REACH.

ROHS1.jpg

Highest levels of analytical accuracy and precision 


The RoHS Calibration Standards guarantee the highest levels of analytical accuracy and precision over a wide concentration range of elemental determination - from low ppm to low percentage. They offer unrivalled homogeneity and are the closest, in respect of composition, to official EU BCR 681k and 680k Certified Reference Materials. This enables compliance with confidence. The concentrations are validated by analysis with multiple analytical techniques.


Ideal for use with several polymer types, including PolyPropylene (PP), PolyEthylene (PE) and others, the RoHS Calibration Standards extend Malvern Panalytical’s range of innovative industry solutions designed to meet environmental legislation challenges such as RoHS 2, WEEE and ELV. 

A unique property of Malvern Panalytical’s RoHS solutions is the carefully selected uncorrelated concentrations for all elements that enable accurate determination of line overlap correction factors. The ultimate benefit is improved accuracy. 

ROHS2.jpg

RoHS Calibration standards for XRF 


The RoHS Calibration Standards module comprises of: 

  • A suitcase for safe storage 
  • 4 multi-element standards and a blank (4 replicates of each) in pressed discs with excellent surface flatness for reproducible light element calibrations
  • Uniquely numbered certificate and documentation
  • CD containing application templates and relevant documentation

ROHS3.jpg

Alternatively, an economic RoHS Calibrations Standards basic package can be ordered. This basic package contains two replicates of all multi-element standards, each incorporating four reference materials plus blank material in duplex, making a total of ten discs. 


The standards consist of PE discs containing chemicals, representing the elements 

and compounds regulated by RoHS 2. The elements and concentration ranges are as follows: 

 

Elements

 

   Concentration range (mg/kg)

Cr

   0 - 973

Cl

   0 - 1075

S

   0 - 591

Zn

   0 - 976

As   

   0 - 145

Br

   0 - 980

Cd

   0 - 252

Sb

   0 - 345

Hg

   0 - 483

Pb

   0 - 1033

Sn

   0 - 178

  ROHS4.jpg

RoHS Calibration Standards for XRF 

The perfect combination: Epsilon 3X with RoHS Calibration Standards for screening and quantification 

Polymeric compliance is important and requires that no restricted substances are present in materials. Aiming for restricted substance levels in polymers that just comply, can go wrong when materials are combined because the cumulative quantities can be higher than accepted limits.

Epsilon 3X is ideal for low-level screening, whereas Epsilon 3XLE, with best-in-class performance, is ideal for low-level quantification at low mg/kg (ppm)-levels. With virtually no sample preparation, it is now possible to determine accurately these elements at sub mg/kg levels when calibrating with the RoHS Calibration Standards.

ROHS5.jpg

Quality Audit Standards

Malvern Panalytical’s Quality Audit Standards have been produced to provide users of Malvern Panalytical’s laser diffraction and imaging-based particle size analyzers with a one-shot, polydisperse transfer standard that enables them to verify the performance of their systems on a regular basis.

If your particle size analyzer is used as a quality control tool, it is inevitable that an occasion will arise where a sample batch you are measuring will be reported to be out of specification. In such a situation, confirmation that the particle size analyzer is performing correctly will help to eliminate any concerns that the analytical system has led to the reported failure. 

Malvern Panalytical’s Quality Audit Standards are designed provide a reliable means of checking and documenting the correct operation of the Mastersizer, Spraytec and Morphologi G3SE / G3SE-ID systems, supporting their use in quality control applications as part of FDA or other international laboratory accreditation schemes (e.g. ISO, NAMAS, and IAF).

Malvern Panalytical’s Quality Audit Standards are:

  • Compliant with ISO13320:2009, USP<429> and EP 2.9.31 guidance relating to the verification of laser diffraction systems.
  • Single-shot samples, reducing the sampling errors associated with measurements.
  • Provided with detailed measurement procedures to aid their routine use within quality control laboratories.
  • Made of an inert material, ensuring a long shelf life.
  • Produced from the world’s largest particle size standard master batch, ensuring many years of consistent supply.

GPC and SEC Standards

A range of molecular weight standards for different applications of GPC/SEC

Malvern Panalytical offers a wide range of molecular weight standards for GPC/SEC for conventional and universal calibration as well as light scattering.


Malvern offers a wide selection of molecular weight standards for GPC/SEC. These are available as pre-weighed standards for ease of preparation. Simply add the correct volume of the required solvent to prepare these molecular weight and intrinsic viscosity standards at a known and accurate concentration.


Standards for conventional and universal column calibration have a broad molecular weight range and are available for organic and aqueous applications.


Standards for light scattering and triple detection are characterized using instruments verified with NIST-traceable materials and are available for organic and aqueous applications.  They can be used to simultaneously calibrate and normalize detectors and to determine inter-detector volumes and peak broadening parameters.

  • Pre-weighed molecular weight standards reduce preparation time and effort and increase reproducibility
  • Column calibration standards cover a wide molecular weight range
  • NIST-traceable light scattering/triple detection standards
  • Calibrate and normalize detectors and calculate detector offsets and band broadening corrections in a single step to reduce calibration time
  • Polystyrene and PMMA standards for organic applications
  • Polyethylene oxide, pullulan and dextran standards for aqueous applications

Malvern Panalytical’s molecular weight standards are pre-weighed into a glass vial. Simply add the desired amount of solvent to achieve the right concentration.

Column calibration standards are run in series through a GPC/SEC system. The elution times of the various molecular weight standards are then used as a reference for the unknown material. Relative molecular weights are obtained when the standard and sample polymers are different.

Light scattering/triple detection standards are used to characterize the detector responses which are then used in the measurement of absolute molecular weight. Normalization factors, detector offsets and band broadening corrections are calculated simultaneously to reduce calibration time.

GPC_SEC.jpg

Polystyrene (PS)

Standard material : 

Polystyrene (PS)

Applications : 

Synthetic polymers

Calibration type : 

Column calibration & triple detection calibration (narrow) and verification (broad)

Standard type : 

Bulk powder, pre-weighed individually and mixed (for HT-GPC)

Molecular weight range : 

1000 Da – 4.5 MDa


Poly-methyl-methacrylate (PMMA)

Standard material : 

Poly-methyl-methacrylate (PMMA)

Applications : 

Synthetic polymers

Calibration type : 

Column calibration & triple detection calibration (narrow) and verification (broad)

Standard type : 

Bulk powder or pre-weighed

Molecular weight range : 

3 kDa – 1 MDa


Polyethylene oxide (PEO)

Standard material : 

Polyethylene oxide (PEO)

Applications : 

Water soluble polymers

Calibration type : 

Column calibration & triple detection calibration (narrow)

Standard type : 

Pre-weighed

Molecular weight range : 

50 kDa to 250 kDa


Pullulan

Standard material : 

Pullulan

Applications : 

Water soluble polymers

Calibration type : 

Triple detection calibration (narrow)

Standard type : 

Bulk powder or pre-weighed

Molecular weight range : 

5 kDa to 700 kDa


Dextran

Standard material : 

Dextran

Applications : 

Water soluble polymers

Calibration type : 

Triple detection verification (broad)

Standard type : 

Pre-weighed

Molecular weight range : 

50 kDa – 100 kDa