マスターサイザー 3000E

マスターサイザー3000は、パフォーマンス性、高度なソフトウェア機能などを兼ねそろえたレーザ回折式粒度分布測定装置です。 しかし、お客様の中にはマスターサイザー3000の機能すべてが必要ではない場合があります。 そこで、マスターサイザー3000の基本的な機能を備えた、エントリーレベルの装置、マスターサイザー3000Eをご用意しました。

ソフトウエアのアップデートに関するお知らせ。 

カタログダウンロード
サポート依頼 会員登録

User manuals

Software downloads

14 March 2024

5.0

  • Software rebranded to Mastersizer Xplorer 
  • Mastersizer 3000+ Ultra, Mastersizer 3000+ Pro, Mastersizer 3000+Lab added to the Mastersizer range
  • SOP Architect feature added (compatible with Mastersizer 3000+ Pro and Ultra only, requires a feature key)
  • Size Sure feature added (compatible with Mastersizer 3000+ Ultra only, requires a feature key)
  • Smart manager telemetry data expanded
  • Licence Manager 3.1.2
  • Mastersizer 3000 Legacy Audit trail, record audit trail support
  • Mastersizer 3000 Legacy Audit trail Exporter added to the installer 

This software is Compatible with Mastersizer range: Mastersizer 3000+ Ultra, Mastersizer 3000+ Pro, Mastersizer 3000+Lab, Mastersizer 3000 and Mastersizer 3000E.

See SUN for further details.

Note: This software no longer supports the use of the Malvern Access Control (MAC) or 21CFR Pt.11 feature key. This functionality is now provided via OmniTrust. Users that wish to move on to the OmniTrust platform are now supported to retain access to their existing audit trail information. For more information, refer to the SUN document before installing the software or contact your Malvern Panalytical representative. 

5.0

25 October 2023

4.10

  • Workflow guidance. 
New live data quality guidance during manual measurements and standard operating procedures


Software version 4.0 introduced OmniTrust to the Mastersizer platform. OmniTrust is Malvern Panalytical’s solution for regulatory compliance and data integrity across different product ranges.

For our pharmaceutical customers currently using the Malvern Access Configurator (MAC) and/or 21CFR features of Mastersizer v3.88 and below - we recommend remaining on your existing version until an upgrade path is available, as the system audit trails are not currently compatible with this new OmniTrust version of Mastersizer application software.

See SUN for further details.

4.10

18 September 2023

4.01


Version 4.01 is a maintenance upgrade. 

Software version 4.0 of the software introduced OmniTrust to the Mastersizer platform. OmniTrust is Malvern Panalytical’s solution for regulatory compliance and data integrity across different product ranges.

For our pharmaceutical customers currently using the Malvern Access Configurator (MAC) and/or 21CFR features of Mastersizer v3.88 and below - we recommend remaining on your existing version until an upgrade path is available, as the system audit trails are not currently compatible with this new OmniTrust version of Mastersizer application software.

See SUN for further details

4.01

18 August 2023

4.0

  • OmniTrust integration
  • NET6 upgrade
  • New UI theme
  • Maintenance upgrades

For our pharmaceutical customers currently using the Malvern Access Configurator (MAC) and/or 21CFR features of Mastersizer v3.88 and below - we recommend remaining on your existing version until an upgrade path is available, as the system audit trails are not currently compatible with this new OmniTrust version of Mastersizer application software.

See SUN for further details

4.0

18 November 2022

3.88

  • Maintenance release, see SUN for details.
3.88

31 October 2022

3.87

  • Maintenance release, see SUN for details.
3.87

03 August 2022

3.86

  • Maintenance release, see SUN for details.
3.86

01 April 2022

3.85

  • Maintenance release, see SUN for details.
3.85

04 January 2022

3.84

  • Maintenance release, see SUN for details.
3.84

15 November 2021

3.83

  • Maintenance release, see SUN for details.
3.83

29 September 2021

3.82

  • Maintenance release, see SUN for details.
3.82

02 September 2019

3.81

  • Updated cleaning features and settings
  • Measurement record and report improvements
3.81

13 June 2019

3.80

  • Updated cleaning features and settings
  • Measurement record and report improvements
3.80

16 October 2018

3.72

  • Maintenance release
3.72

17 October 2018

3.71

  • Audit history view and export
3.71

26 September 2017

3.63

  • Maintenance release
3.63

30 November 2016

3.62

  • Materials database details update
  • Audit improvements
  • Distribution preview update
  • Report improvements
3.62

29 March 2016

3.50

  • Sample Detail Recall
  • Close measurement manager option
  • Edit Graphs without entering edit mode
  • Search for SOPs
  • Search for measurement records across multiple files
  • Row alignment setting for parameter grids
3.50

29 September 2015

3.40

  • Background stability function in measurement manager
  • Brand new instrument simulation framework: Custom simulation scenarios / Easy to make changes to simulators using macro editor
  • Ability to fill from two external dispersant sources via macro
  • Live scattering and obscuration available via automation interface
  • Various bug fixes, including known issues
3.40

15 June 2015

3.30

  • Brand new reporting framework: Increased customization of size and arrangement of widgets / Improved use of space / Increased customization of report header
  • Hyperlinks to advice in data quality
  • Various bug fixes, including known issues
  • Automatic scan for OPO
3.30

26 September 2014

3.10

  • Support for the Hydro SV dispersion unit
  • Improved options for dispersant selections
  • Background alarms to test system cleanliness
  • PDF file and batch printing improvements
  • Improvements in audit trail storage location handling
  • Easier software licence management
  • Various other improvements and bug fixes
3.10

24 February 2014

3.0

  • Optical property optimizer tool
  • Result emulsion factors
  • Improved accessory clean sequences
  • Various other improvements and bug fixes
3.0

25 October 2021

2.21

Malvern Access Configurator (MAC) software
  • Security and maintenance release. See SUN for details.
2.21

20 September 2013

2.20

  • Full support for the Mastersizer 3000E
  • Analysis option to mimic the performance of the Mastersizer 2000E
  • Ability to recalculate Mastersizer 2000 results within the Mastersizer 3000 software
  • Import measurement files from older Mastersizer systems (Mastersizer S, X, Micro, and Micro+)
  • Skewness, Kurtosis, and Standard Deviation available as record parameters
  • Results can be displayed as surface area distributions
  • Save As option added for reports, enabling new reports to be created from existing reports
  • Improved performance of record view actions, including copy/paste functions
  • Improved handling of corrupted data files
  • Various bug fixes
2.20

26 June 2018

2.20

Malvern Access Configurator (MAC) software
  • Searching and exporting the audit history
2.20

05 September 2017

2.10

Malvern Access Configurator (MAC) software
  • Initial release
2.10

31 March 2015

1.01

Hydro Sight software - Maintenance update
1.01

30 September 2014

1.0

Hydro Sight accessory self demo software
1.0

14 November 2014

1.0

Hydro Sight software - initial release
1.0

アクセサリ

マスターサイザー3000E用分散ユニットアクセサリ

マスターサイザー3000E BasicとExtended

Hydro Insight

より詳細な材料分析へ

Hydro Insightは、Mastersizer 3000と並べて配置されたダイナミックイメージングアクセサリで、粒度分布を超えて、粒子像や定量粒子形状データの洞察を提供します。 

このようにして、科学者、研究者、品質管理マネージャーが、材料をよりよく理解し、メソッドを迅速に開発し、トラブルシューティングを簡素化することができます。

Hydro SV

小容量対応湿式分散ユニット

Hydro SVは、小容量の試料と分散媒で粒子径分析を可能にするために設計されたシンプルでコストパフォーマンスの高い湿式分散ユニットです。

Hydro EV

フレキシブルな湿式分散ユニット

ディップイン式の湿式サンプル分散ユニットです。標準のラボ用ビーカー等で利用できます。 あらゆる容量の分散媒やさまざまなサイズの粒子径に対応しています。

Hydro SM

エントリーレベルの小容量湿式分散ユニット

Hydro SM は、溶媒の使用を最小限に抑える必要がある非水性分散媒の中の試料を測定するために作られたコストパフォーマンスの高い湿式試料分散ユニットです。

Aero M

バルク乾燥粉体サンプルのルーチン粒度分布解析

Aero M乾式分散ユニットにより、マスターサイザー3000E粒度分布測定器を使用してバルク乾燥粉体サンプルの測定ができます。 シンプルな設計になっているため使いやすくメンテナンスが容易なので、日常的な生産や品質管理作業の一部として堅牢で再現性の高い粒度分布測定を実現します。

Aero用ファネルサンプルフィーダー

バルク粉体試料の高速品質管理測定に

Aeroファネルサンプルフィーダーは、Aero SおよびAero M乾式分散ユニットに、蓋を開けることなく試料を直接投入することによって、高速かつ再現性のある乾燥粉体の粒度分布測定が行えるよう設計されています。 これにより、試料分析のために試料を導入する工程を迅速化・簡素化できるため、測定結果を得るまでの時間を短縮できます。

マスターサイザー3000チョコサイザー

チョコレート生産における効果的な品質管理

チョコレート生産の目標は、経済的で効率的な方法で、一貫した風味と口当たりの製品を生産することです。 この目標を達成するには、ココア固体とミルク固体の粒径と粒度分布を管理することが大切です。 高速で信頼性の高い粒度分布解析を簡単に行う方法を提供することにより、チョコレート生産と品質管理をサポートするためにマスターサイザー3000チョコサイザーは開発されました。

マスターサイザー3000E Extendedのみ

Hydro MV

中容量自動分散ユニット

Hydro MVは、粒子径分析用の中容量の自動湿式分散ユニットです。 サンプル量が比較的少ない場合に最適で、水溶性、非水溶性の溶媒にも対応します。

Hydro LV

大容量対応 湿式分散ユニット

Hydro LVは大容量の湿式用自動分散ユニットです。 粒子径が大きい場合や、粒度分布が広い場合に特に適しています。

Software add-ons

Data Quality Guidance

Making good data excellent

Data Quality Guidance is a software add-on that flags possible data quality issues, and provides a list of causes and solutions at all stages of your measurement.

Events and Training

All Events

サポート契約のオプション

Malvern Panalyticalのサービスプランは、常にお客様の資産を守り、最適なパフォーマンスを保証します。

お客様がMalvern Panalytical製品をお買い求めになってから、製品が寿命を迎えるまで、Malvern Panalyticalはお客様を継続的にサポート致します。 お客様のニーズに応じて、Malvern Panalyticalが最適なサポートをご提供致します。

ヘルプデスク

トレーニング

  • ユーザトレーニングイベント

ソフトウェア ダウンロード

Malvern Panalyticalのサービスオプション:お客様に最適なプランをお選びください。

Malvern Panalyticalプラチナプラン

装置の使用可能時間を最大限に高めることが日々の装置パフォーマンスには重要と考えておられるラボに。 当社のハイレベルな対応と「包括的」費用プランが、不測の事態が生じた場合の予期せぬ修理費用をカバーします。

Malvern Panalyticalゴールドプラン

装置効率を維持することで、お客様のラボの生産性を高めます。 上記の優先対応を受けていただきながら、専門家による技術サポート・ソフトウェアサポートも併せ、お使いの装置が性能を発揮できるようサポート致します。

Malvern Panalyticalブロンズ訪問点検

装置性能の最適化に注目しているラボには、予防保守がきわめて重要となります。

プラチナプランゴールドプランブロンズ訪問点検
年間PM/PVテスト
あり
あり
いいえ
電話/Eメールサポート
あり
あり
いいえ
優先対応
あり
あり
いいえ
急な故障時の訪問点検*
あり
あり
いいえ
部品込み
あり
いいえ
いいえ
技術サポートおよびソフトウェアサポート
あり
あり
あり
据え付け時適格性確認(IQ)/稼働性能適格性確認(OQ)(医薬)***
あり
あり
あり

*作業費用および出張費用を含む***追加料金にて提供可

サポート依頼