자료 센터

Exclusive content at your finger tips

173 results

Sort search results by or

Page 1 of 18
기술노트

04 April 2024 | English

Aeris Cement Edition Sample Preparation Standard Operational Procedure

The Aeris Cement edition makes it possible for cement plants and central laboratories to do fast, easy and reliable mineralogical monitoring for different materials with quantitative X-ray diffraction. The built-in automatic mineralogical analyses that use the Rietveld method are calibrated on reference materials and actual production samples and can be changed to specific mineralogy or sample ...

제품:
Aeris Cement edition
기술 유형:
X-ray Diffraction (XRD), X-ray Fluorescence (XRF)
산업:
건축자재, 시멘트
Aeris Cement Edition Sample Preparation Standard Operational Procedure
기술노트

04 March 2024 | English

NanoSight Pro – Size, Polysdispersity, and Span

IntroductionThe diversity of particle characterization techniques, each with their own data outcomes and definitions for reporting particle size, results in confusion when employing multiple analytical tools in a laboratory. A question that commonly arises is “which size definition is the most suitable for a particular technique and which one is optimal for data comparison?” Often, the complexity ...

제품:
NanoSight Pro
기술 유형:
나노 입자 추적 분석
NanoSight Pro – Size, Polysdispersity, and Span
기술노트

26 January 2024 | English

Zetasizer Lab Blue label - system for water treatment

The Zetasizer LAB is an ideal tool for your coagulant monitoring effort. In today’s treatment plants you need to optimize coagulant dose at variable water conditions. With zeta potential, operators gain quantitative data to target the treatment process. Simply sample, fill the flow cell, insert and press go. Results of 3 separate zeta potential measurements in 2 minutes. Costs of coagulants ...

제품:
Zetasizer Lab (Blue)
산업:
수처리
Zetasizer Lab Blue label - system for water treatment
기술노트

11 January 2024 | English

Binding of ACE-2 to the viral spike protein receptor binding domain

The WAVEsystem, a Creoptix technology, is a cutting-edge optical biosensor built upon the GCI technology. The WAVEsystem measures binding affinity and kinetics label-free using a sensor chip, the WAVEchip. Because of the unique design of the WAVEchip, the WAVEsystem can measure affinity and kinetics from weak to tight binders (ka = 102 – 3x109 M-1 sec–1; Kd = 10–6 – 10 sec–1 and binding affinities ...

제품:
WAVEsystem, WAVE Chip
Binding of ACE-2 to the viral spike protein receptor binding domain
기술노트

18 October 2023 | English

Upgrading with Data Quality Guidance

IntroductionUsers of any laser diffraction system, including the Mastersizer 3000 and Mastersizer 3000E, know that there are numerous factors which contribute to the quality of the data achieved. Without suitable attention paid to controlling each of these factors, data quality issues can arise which can impact the accuracy and reliability of the measured particle size distribution (PSD). ...

제품:
Mastersizer 시리즈, Mastersizer 3000, Mastersizer 3000E
Upgrading with Data Quality Guidance
기술노트

13 September 2023 | English

NanoSight NS300 Tube Configurations

Since the NS300 has been reclassified as a Class 3R laser product, the aperture in the instrument case must be covered. The NS300 was originally shipped with a bulkhead tubing connector. This was often removed and misplaced. We are now offering a cheaper 3D printed tube slot which is much easier to use. It is recommended that any user who has no bulkhead connector fitted order this replacement ...

제품:
NanoSight NS300
기술 유형:
나노 입자 추적 분석
NanoSight NS300 Tube Configurations