Epsilon 1 for automotive catalysts recycling

Looking for an easy but accurate solution?

Want to get better accuracy and precision from your handheld XRF spectrometer, while keeping your workflow as simple as possible? Our Epsilon 1 ED-XRF spectrometer is here for you.

Epsilon 1 produces precise, accurate data – quickly, cost-effectively, and with minimal operator involvement or sample preparation. It’s set up for Pd, Pt, and Rh analysis directly from the factory, so you can get started straight away. And the spectrometer is designed for ultra-safe operations and reproducible sample positioning. Plus, with its compact, robust design, all you need is a regular main connection!

This easy operation makes Epsilon 1 the ideal choice for high-quality, on-site XRF analysis.

下載型錄
索取報價 要求演示 聯繫銷售部門

Overview

Epsilon 1 will be pre-calibrated in the factory for analyzing of Pt, Pd and Rh in spent automotive catalytic convertors. Put loose powder in a sample cup and measure directly. 

[Periodic_Table_Epsilon_1_automotive_catalyst_recycling.jpg] Periodic_Table_Epsilon_1_automotive_catalyst_recycling.jpg

The accuracy of the method is validated by measuring Certified Reference Materials. The results clearly demonstrate the capability of Epsilon 1 for the analysis of valuable precious metals Pt, Rh and Pd in catalytic converters. 

Sample name (repeats) Compounds Certified conc. Average conc. RMS Rel. RMS (%)
NIST 2556 (20x) Pt (ppm) 697.4 +/- 6.3 695.6 7.2 1.1
Rh (ppm) 51.2 +\- 0.5 53.9 2.0 3.7
Pd (ppm) 326 +/- 1.6 322.8 7.2 2.2
NIST 2557 (20x) Pt (ppm) 1131 +/- 1.9 1189.6 13.2 1.1
Rh (ppm) 135.1 +/- 1.9 141.6 2.2 1.6
Pd (ppm) 233.2 +/- 1.9 236.9 3.6 1.5
ERM-EB504a (5x) Pt (ppm) 1414 +/- 9.0 1424.8 5.1 0.4
Rh (ppm) 210 +/- 2.2 216.2 2.3 1.1
Pd (ppm) 1596 +/- 11 1675.1 18.3 1.1
FLX 133 (5x) Pt (ppm) 465 +/- 32 462.1 4.0 0.9
Rh (ppm) 242 +/- 4 237.6 4.0 1.7
Pd (ppm) 1075 +/- 33 1093.8 15.3 1.4

Features

[icon calibrate.png] icon calibrate.png

Factory calibrated

[icon operator simplicity button.png] icon operator simplicity button.png

Operator friendly

[icon gamma-ray x-ray shielded.png] icon gamma-ray x-ray shielded.png

X-ray shielded

[icon trust shield with tick.png] icon trust shield with tick.png

High level of trust

Guaranteed maximum safety

All Malvern Panalytical X-ray solutions are designed according to the strict regulations of regulatory bodies. The Epsilon 1 tabletop system shields its users against X-rays during analysis. 

You’ll have peace of mind in the lab thanks to a unique internal interlocked enclosure providing complete radiation protection, deserving its Vollshutz classification. No need to worry about safety as the system is fully enclosed and completely safe.

Guaranteed maximum safety

Be Flexible

Sometimes, it’s just not possible or worthwhile to calibrate all your sample types. Perhaps there are no standards, or those that are available are too expensive. But you can still use a generic method to analyze the elemental composition of a single sample. Even better – this method is available on our Epsilon 1 XRF benchtops.

How does this work? By using our standardless Omnian software! Combining twenty generic samples with the power of physics, Omnian can quantify elemental composition for a wide variety of sample types – including polymers and liquids. 

Be Flexible

內建完整系統

內建電腦的作業系統為 Microsoft Windows 10,具備強效的 CPU 與 120 GB 的硬碟,可確保儀器能靈活儲存並處理上千筆結果。高解析度 10.4 吋 LCD 觸控螢幕為簡易導引式操作的理想選擇。

若要操作螢光分析儀,請接上標準市電,然後即可開啟電源。 

內建完整系統

方便通訊

標準計算機外圍設備的 USB 與網路連接支援擴展使用、應用開發與操作員操作。

方便通訊

防溢保護

為了保護系統的脆弱核心,防溢箔片已經準備好了。若是發生溢出的情況,操作員可以輕鬆地更換箔片。

防溢保護

Accessories

標準品(參考材料)

RoHS

精確分析 RoHS 限制性物質元素的 XRF 標準品
RoHS

TOXEL

精確分析聚合物及塑膠中有毒元素的 XRF 標準品
TOXEL

CRMs

Claisse 滿足您的所有需求!
CRMs

軟體

Epsilon 應用軟體

Epsilon 軟體是 XRF 分析軟體平台,能與 PANalytical 的 Epsilon 1 與 Epsilon 4 系列桌上型 EDXRF 系統搭配使用。

Epsilon 應用軟體

Stratos

此軟體可提供快速、簡單及非破壞性的方式分析塗層、表面層及多層結構。
Stratos

Omnian

當特定方法或認證標準品不易或無法取得時,Omnian 軟體能提供給您最好的分析結果。

Omnian

FingerPrint

FingerPrint 軟體模組搭配 Epsilon EDXRF 系統,非常適合進行快速材料比對測試。

FingerPrint

Support

Services

Solutions to maximize the return on your investment

To assure that your instrument remains in top condition and performs on the highest level, Malvern Panalytical offers a wide range of services. Our expertise and support services assure an optimal functioning of your instrument.

Support

Service for a lifetime

  • Phone and remote support
  • Preventive maintenance and checkups
  • Flexible Customer Care Agreements
  • Performance certificates
  • Hardware and software upgrades
  • Local and global support

Expertise

Adding value to your processes 

  • Sample preparation development/optimization
  • Analytical methodologies 
  • Turnkey solutions for XRD 
  • Operations via IQ/OQ/PQ, quality assurance (GLP, ISO17025) or round robins/inter laboratory studies
  • Automation of lab processes
  • Consultancy services

Training and education

  • Training on-site or at our competence centers
  • Broad range of basic and advanced courses on products, applications and software

Analytical services and calibration materials

  • Expert (XRF) analyses services
  • Oxides and trace analysis
  • Customized calibration materials