Zetasizer Advance Series User Guide (English)
Version number: MAN0592-15-EN
New Zetasizer Advance – DLS for every application – meet the new Zetasizer Family!. Find out more
Find out moreOur Zetasizer Lab system offers traditional 90-degree side-scatter size measurements but still offers enhanced features. The Zetasizer Lab incorporates Adaptive Correlation, M3-PALS and constant current zeta mode as well as our extended size range analysis when used with ZSU1002 capillary cell. The Zetasizer Lab also ships with ZS Xplorer, our easy-to-use analytical software. ZS Xplorer offers instant feedback on data quality, and guidance on how to improve your results.
Works with OmniTrust: Malvern Panalytical's compliance solution for the regulated environment
Version number: MAN0592-15-EN
Version number: MAN0593-10-EN
Version number: MAN0604-05-EN
Version number: MAN0593-08-ZH
Version number: MAN0593-08-JA
Version number: MAN0593-06-FR
Version number: 07
Version number: MAN0593-05-EN
Maintenance release, updates to key services and addition of Titration summary data logs.
See SUN for full details.
ZS Xplorer version 3.3 extends OmniTrust support to the Studies features of the main application. Previously OmniTrust users were prevented from accessing Studies to prevent un-audited events. From 3.3 OmniTrust users can now access Studies for Molecular Weight and associated parameters with permissions and auditing of events within the Studies features.
Note that Studies by their nature are intended for advanced users and to be flexible in their analysis. Users not requiring Studies features can still prevent access to these features using permissions in OmniAccess.
Version 3.3 also addresses a few minor bug fixes.
See SUN for full details.
ZS Xplorer 3.2.2 has the following updates:
Software re-branded to Malvern Panalytical brand
Minor bug fixes - one of which may have prevented instrument connection
Bug fix for OmniTrust users that meant editing of records was possible, even when user permission for this action was disabled (recommended update for OmniTrust users currently on ZS Xplorer 3.2.1.)
Updated Toluene calibration routine to prevent incorrect reporting of issues with calibration.
See SUN for full details.
ZS Xplorer 3.2.1 adds Smart Instrument enrollment - the first step in bringing Zetasizer into Malvern Panalytical's Smart Manager services.
Several installer improvements have been made to reduce ZS Xplorer requirements around .NET and WebView2 components.
We have also added ability to edit peak thresholds for size measurements and refinements on CSV exporting from parameter tables.
See SUN for full details.
ZS Xplorer version 3.2.0 adds upper and lower display range configuration for Size/MADLS & Particle Concentration measurements.
Introduces Data Quality Advice for MADLS & Particle Concentration measurements.
Adds further Trend analysis improvements and bug fixes.
Extends Japanese and Chinese localization to Studies and Data Quality Advice.
Adds speed and robustness improvements to Scattering standard measurements.
Other improvements and bug fixes.
See SUN for full details.
ZS Xplorer version 3.1.0 extends studies and concentration trend measurements to support the Zetasizer Advance Lab models and also adds the capability to perform concentration trends in either back or side scatter on Zetasizer Advance Ultra models. Concentration trends also now supports setting of measurement temperature and adds display of R2 value to tables and graphs.
Exporting of data to CSV file from graphs and tables in Concentration trends and from Parameter and Statistic tables in Analyze views has been introduced.
Data quality advice for Zeta potential measurements has been further refined to provide users with better diagnosis of sample/measurement issues.
Exporting a study now provides an option to include the results data for transfer of the complete study between data repositories.
Various bug fixes, see software update notification for details.
ZS Xplorer version 3.0.0 introduces studies and concentration trend measurements for the determination of molecular weight by static light scattering and kD by dynamic light scattering. Note: This first release does not support Zetasizer Lab or OmniTrust users. Auto averaging for Zeta, MADLS and Particle concentration has also been added along with other quality of life features and bug fixes. See SUN for details.
ZS Xplorer version 2.3.1 introduces post-analysis averaging for Zeta, Particle Concentration and MADLS size measurements. Zeta mobility parameters and graphs have
been added, as well as a count rate meter and
localization for Chinese (Simplified) and Japanese language support.
Important: This version supports OmniTrust 1.4.0; OmniTrust users should upgrade their installation to 1.4 if upgrading to ZS Xplorer 2.3.1.
ZS Xplorer version 2.3.0 introduces post analysis averaging for Zeta, Particle Concentration and MADLS size measurements. Zeta mobility parameters and graphs have also been added, as well as a count rate meter.
Important: This version supports OmniTrust 1.4.0; OmniTrust users should upgrade their installation to 1.4 if upgrading to ZS Xplorer 2.3.0.
details.
OmniAccess
OmniTrail
More information can be found in the Release and Installation Notes.
OmniAccess
OmniTrail
More information can be found in the Release and Installation Notes.
Configure the Zetasizer Lab for your applications and requirements with our range of configuration options:
The MPT-3 is a cost-effective accessory for the Zetasizer Advance range, designed to automate your Zeta and/or Size vs. pH titrations, helping you understand how your materials behave as a function of pH.
The zeta potential and/or size of your materials with pH changes can be critical in understanding:
The SV-10 measures viscosity with the accuracy required for dynamic light scattering, for the conversion of diffusion speed to size, and electrophoretic mobility to zeta potential, in an extremely simple and rapid system.
The zeta potential of colloids and molecules is extremely sensitive to contamination from components of a previous sample used in a measurement cell. The use of a disposable cell completely eliminates this potential contamination issue.
The folded capillary cell provides the benefits of the accuracy of measurement of a capillary cell with the ease of use of a disposable cell.
Although, disposable, including the electrodes, for low conductivity samples each cell can be used for hundreds of measurements if required.
The cell can be used with the autotitrator, where multiple measurements are routinely done over a wide pH range.
Our low volume disposable sizing cell (ZSU1002) design is unique in offering easy-fill, ultra-low volume size measurement in as little as 3 μL.
The high concentration cell enables the measurement of the zeta potential of samples with little or no dilution in any Zetasizer Advance system that measures zeta potential.
The cell has a flow configuration so can be used for stop-flow size and zeta potential measurements using an MPT-3 autotitrator as well as batch measurements.
Protect your investment and ensure optimized performance at all times with Malvern Panalytical’s service plans.
When you purchase a Malvern Panalytical product we understand that this is just the first stage of a working relationship that will last for the lifetime of the instrument. Depending on your needs, Malvern Panalytical will provide the support for your business.
For laboratories where maximizing instrument up-time is critical to its daily performance. Our highest level of response and the 'all inclusive' price plan takes care of those unexpected repair bills should the unfortunate occur.
Enhance your laboratory productivity by maintaining instrument efficiency. Still receive that priority response, combined with specialist technical and software support, we'll keep your instrument performance on track to deliver.
For laboratories looking to optimize instrument performance, regular preventative maintenance is essential.
Platinum Plan | Gold Plan | Bronze Visit | |
---|---|---|---|
Annual PM/PV Test | yes | yes | no |
Telephone / Email Support | yes | yes | no |
Priority Response | yes | yes | no |
Emergency Breakdown visits* | yes | yes | no |
Parts Included | yes | no | no |
E-Learning** | yes | yes | no |
Technical & Software Support | yes | yes | yes |
IQ/OQ (Pharma)*** | yes | yes | yes |
*including labour & travel costs** Platinum 2 places per contract term, Gold 1 place per contract term***available at an additional cost