From impurities to catalysts; from crystal structure to characterization of chemicals, we provide essential tools for chemists. Being absolutely sure about which chemical you deal with, and in what phase it is presented, is one of the benefits of using XRD. Particle size and shape analyses are key parameters for processing and end-product qualities in the many chemical industrial applications. In contrast, XRF provides means to determine the elemental composition. For instance, XRF can determine the low-level (mg/kg) elemental impurities or catalyst residues in your products. 

Typical applications include:

  • Phase identification and confirmation 
  • Crystal structure refinement with unrivalled resolution
  • Elemental composition and impurities determination
  • REACH compliance and REACH sameness using full-pattern analysis and cluster analysis to enable the comparison
  • Particle size and shape analysis 
  • Simple yes/no confirmation if you deal with the expected chemicals of for instance everyday incoming goods

REACH compliance

XRD uniquely identifies your (semi-) crystalline chemicals. Malvern Panalytical’s X-ray diffractometers are fast and ideally suited for operator-friendly operation. Moreover it is accurate, simple and fully automated. For example, identification for REACH sameness, is now a simple push-button operation. 

The Empyrean X-ray diffractomer enables the widest range of XRD techniques on one platform. It is ideal for more research-oriented environments including particle shape and size determination possibilities and in situ reaction monitoring. 

Malvern Panalytical’s wavelength dispersive (WD) and energy dispersive (ED) spectrometers belonging to the Zetium and Epsilon 4 respectively, deliver the flexibility and robustness needed to meet the demands for flexibility in the chemicals production environments. The Epsilon 4 range with FingerPrint software for example provides operator-friendly and efficient solutions for quality control. 

Linha Zetasizer

Linha Zetasizer

Os sistemas mais usados no mundo inteiro para medição de nanopartículas, tamanho de partículas biomoleculares e coloides e de carga de partículas

Mais detalhes
Medição Tamanho molecular, Massa molecular, Tamanho da partícula, Potencial Zeta
Faixa de temperatura 0°C - 120°C
Faixa de tamanho das partículas: 0.3nm - 10µm
Tecnologia Espalhamento de luz, Espalhamento de luz dinâmico, Espalhamento de luz eletroforético, Espalhamento de luz estático
Tipo de dispersão Via úmida
Tipo de célula de amostra Cuvette
Molecular Measurement Type Chromotography, Batch measurement

Variedades do Empyrean

Variedades do Empyrean

A solução multifuncional para suas necessidades analíticas

Mais detalhes
Medição Forma da partícula, Tamanho da partícula, Crystal structure determination, Identificação de fase, Phase quantification, Contaminant detection and analysis, Epitaxy analysis, Interface roughness, 3D structure / imaging
Configuração de Goniômetro Vertical goniometer, Θ-Θ
Tecnologia X-ray Diffraction (XRD)

Zetium

Zetium

Excelência elementar

Mais detalhes
Medição Identificação química, Metrologia de filme fino, Elemental analysis, Contaminant detection and analysis, Elemental quantification
Gama elementar Be-U
Resolução (Mg-Ka) 35eV
LLD 0.1 ppm - 100%
processamento de amostra 160per 8h day - 240per 8h day
Tecnologia Wavelength Dispersive X-ray Fluorescence (WDXRF), Energy Dispersive X-ray Fluorescence (EDXRF)

Série Epsilon

Série Epsilon

Rapidez e precisão na análise elementar e em linha

Mais detalhes
Medição Metrologia de filme fino, Elemental analysis, Contaminant detection and analysis, Elemental quantification
Gama elementar Na-Am
Resolução (Mg-Ka) 145eV
LLD 1 ppm - 100%
processamento de amostra Up to - 160per 8h day
Tecnologia X-ray Fluorescence (XRF), Energy Dispersive X-ray Fluorescence (EDXRF)

Linha Zetasizer

Linha Zetasizer

Os sistemas mais usados no mundo inteiro para medição de nanopartículas, tamanho de partículas biomoleculares e coloides e de carga de partículas

Variedades do Empyrean

Variedades do Empyrean

A solução multifuncional para suas necessidades analíticas

Zetium

Zetium

Excelência elementar

Série Epsilon

Série Epsilon

Rapidez e precisão na análise elementar e em linha

Mais detalhes Mais detalhes Mais detalhes Mais detalhes
Medição Tamanho molecular, Massa molecular, Tamanho da partícula, Potencial Zeta Forma da partícula, Tamanho da partícula, Crystal structure determination, Identificação de fase, Phase quantification, Contaminant detection and analysis, Epitaxy analysis, Interface roughness, 3D structure / imaging Identificação química, Metrologia de filme fino, Elemental analysis, Contaminant detection and analysis, Elemental quantification Metrologia de filme fino, Elemental analysis, Contaminant detection and analysis, Elemental quantification
Faixa de temperatura 0°C - 120°C      
Faixa de tamanho das partículas: 0.3nm - 10µm      
Configuração de Goniômetro   Vertical goniometer, Θ-Θ    
Gama elementar     Be-U Na-Am
Resolução (Mg-Ka)     35eV 145eV
LLD     0.1 ppm - 100% 1 ppm - 100%
processamento de amostra     160per 8h day - 240per 8h day Up to - 160per 8h day
Tecnologia Espalhamento de luz, Espalhamento de luz dinâmico, Espalhamento de luz eletroforético, Espalhamento de luz estático X-ray Diffraction (XRD) Wavelength Dispersive X-ray Fluorescence (WDXRF), Energy Dispersive X-ray Fluorescence (EDXRF) X-ray Fluorescence (XRF), Energy Dispersive X-ray Fluorescence (EDXRF)
Tipo de dispersão Via úmida      
Tipo de célula de amostra Cuvette      
Molecular Measurement Type Chromotography, Batch measurement      

Linha Zetasizer

Variedades do Empyrean

Zetium

Série Epsilon

Linha Zetasizer Variedades do Empyrean Zetium Série Epsilon

Os sistemas mais usados no mundo inteiro para medição de nanopartículas, tamanho de partículas biomoleculares e coloides e de carga de partículas

A solução multifuncional para suas necessidades analíticas

Excelência elementar

Rapidez e precisão na análise elementar e em linha

Mais detalhes Mais detalhes Mais detalhes Mais detalhes
Tecnologia
Espalhamento de luz
Espalhamento de luz dinâmico
Espalhamento de luz eletroforético
X-ray Diffraction (XRD)
X-ray Imaging
Energy Dispersive X-ray Fluorescence (EDXRF)
Wavelength Dispersive X-ray Fluorescence (WDXRF)