See the current NanoSight range . Learn more

Learn more

NanoSight LM10

O instrumento Malvern NanoSight LM10 oferece uma plataforma reprodutível e fácil de usar para a caracterização de nanopartículas.

O LM10 permite a análise rápida e com precisão da distribuição de tamanho e concentração de todos os tipos de nanopartículas, com diâmetro de 20nm a 1000nm, dependendo da configuração do instrumento e do tipo da amostra.

Contatar suporte Cadastre-se já!

User manuals

Software downloads

05 October 2020

3.44

Capture

    • USB camera support.

Other

    • Improved logging. Instrument log files will no longer be overwritten at the start of each day.

    • Improved handling of corrupt/unreadable video files.

    • New script command for automated/unattended data export.

    • Resolved HASP issues in Windows 10 (Version 2004)

3.44

08 January 2019

3.40

Improvements including:

  • USB camera support
  • Improved logging
  • Improved handling of video files
  • New script commands for data export
3.40

27 July 2018

3.30

Improvements including:

  • New SOP pages
  • CFR
3.30

27 November 2015

3.20

Improved Automation

  • Auto-setup, auto-level, focus-level, and auto-focus script commands available
  • Script command to change experiment filename
  • Make background script commands added
  • Changes to continuous flow SOP scripts to ensure smooth flow

Exports

  • Laser color added to nanolog.csv and other outputs

Interface changes

  • Run button on Recent Measurements page
  • User direction messages for capture and process settings improved
  • User Positions 1 and 2 removed

Additional features

  • Optional CFR feature available – audited operation, secure login, data integrity checking, user level program configuration
  • CFR feature can be enabled by adding feature code to CFR security dongle
  • The CFR feature is available as a chargeable upgrade – Part No. PSS0054 for new builds, Part No. NTA4165 as an upgrade for customers running NTA 3.2 software

Other

  • Extended camera log for diagnostic purposes, can revert to daily usage via nano.ini
3.20

15 June 2015

3.10-I2

Improvements and Features

  • Concentration measurement upgrade option for NS500 and single and multi-laser NS300

Improved Automation

  • Automatic focus available for NS300 and NS500
  • Automatic camera level for all instruments

Data Display and Manipulation

  • Flexible data overlays for line graphs and scatter plots
  • CSV and PDF export options for overlaid data
  • Ability to report concentrations between specific size limits
  • Option to ‘exclude’ regions of particles from the scatter plot
  • Updated display for zeta plots

Interface changes

  • Quick access to recent experiments through dedicated tabbed window
  • Experiments display overlaid graphs and scatterplots on load
  • Improved flexibility and usability for graph settings
  • Filter wheel has its own hardware tab, with customisable buttons
  • Procedure guide for electrode air removal
  • Warnings to remind user of essential hardware checks/maintenance

Additional improvements

  • Refined camera levels to give more suitable settings for brighter particles
  • Refined detection threshold range
  • Speed optimised size distribution algorithm runs up to 20 times faster
  • Refined focus and stage controls for ease-of-use
  • Option to correct viscosity and dilution after making a measurement
  • Improved hardware auto-detection and reconnection menus
3.10-I2

30 March 2015

3.10-I1

Improvements and Features

  • Concentration measurement upgrade option for NS500 and single and multi-laser NS300

Improved Automation

  • Automatic focus available for NS300 and NS500
  • Automatic camera level for all instruments

Data Display and Manipulation

  • Flexible data overlays for line graphs and scatter plots
  • CSV and PDF export options for overlaid data
  • Ability to report concentrations between specific size limits
  • Option to ‘exclude’ regions of particles from the scatter plot
  • Updated display for zeta plots

Interface changes

  • Quick access to recent experiments through dedicated tabbed window
  • Experiments display overlaid graphs and scatterplots on load
  • Improved flexibility and usability for graph settings
  • Filter wheel has its own hardware tab, with customisable buttons
  • Procedure guide for electrode air removal
  • Warnings to remind user of essential hardware checks/maintenance

Additional improvements

  • Refined camera levels to give more suitable settings for brighter particles
  • Refined detection threshold range
  • Speed optimised size distribution algorithm runs up to 20 times faster
  • Refined focus and stage controls for ease-of-use
  • Option to correct viscosity and dilution after making a measurement
  • Improved hardware auto-detection and reconnection menus
3.10-I1

15 July 2014

3.0

Improvements and Features
  • Redesigned interface, focusing around repeat measurements
  • Improved particle size distribution algorithm
  • Automatic, integrated hardware detection and communication
  • Increased compatibility with networked computers
  • Easy setup with new installer package
  • Additional features
  • New file system with less files per experiment
  • Improved particle detection and tracking
  • Improved vibration correction
  • Settings stored in the registry rather than .ini file
3.0

23 February 2024

1.1

  • Project export and import
  • General workflow and existing feature improvements
  • Improved robustness for fluorescence measurements
  • Minor bug fixes

See SUN for more details.

1.1

10 May 2023

1.0

NanoSight Software Activation Tool v1

1.0

14 September 2023

1.0

NS Xplorer is the software for the NS Pro instrument

  • 1st Release
1.0

Acessórios

Bomba de seringa do NanoSight

A bomba de seringa está disponível para todos os sistemas da linha NanoSight permitindo que os usuários realizem a análise da amostra a uma taxa de fluxo constante.

Events and Training

All Events
Webinário - Gravado
Physicochemical Characterization of Nanomedicines: Investigating surface characteristics of nano delivery systems and their interactions with plasma

January 2021 | English

Physicochemical Characterization of Nanomedicines: Investigating surface characteristics of nano delivery systems and their interactions with plasma

Produtos:
Zetasizer Advance Range, NanoSight LM10
Tecnologia:
Espalhamento de luz, Espalhamento de luz estático, Espalhamento de luz dinâmico
Setor:
Biológicos, Farmacêutico, Nanomateriais
Physicochemical Characterization of Nanomedicines: Investigating surface characteristics of nano delivery systems and their interactions with plasma

Opções de contrato de suporte

Proteja seu investimento e garanta estar sempre com a melhor performance com os planos de serviço da Malvern Panalytical.

Ao comprar um produto Malvern Panalytical, entendemos que esta é apenas a primeira etapa de uma relação profissional que durará por toda a vida útil do instrumento. A Malvern Panalytical oferece suporte ao seu negócio de acordo com suas necessidades.

Serviço de apoio ao usuário

Treinamento

  • Eventos de treinamento de usuários

Descargas de software

Opções de serviço da Malvern Panalytical - escolha o plano certo para você:

Plano Platinum da Malvern Panalytical

Para laboratórios onde ter o instrumento operacional é um fator crítico para sua performance diária. Atendimento com alta prioridade. É o plano “tudo incluso” que evita as contas inesperadas de reparos imprevistos.

Plano Gold da Malvern Panalytical

Melhore a produtividade de seu laboratório mantendo a eficiência do seu instrumento. Atendimento com prioridade combinado com o suporte de especialistas técnicos e de software, garantindo a performance de seu instrumento.

Visita Bronze da Malvern Panalytical

Para laboratórios que buscam otimizar a performance dos instrumentos com visitas regulares para manutenção preventiva.

Plano PlatinumPlano GoldVisita Bronze
Teste Anual de PM/PV
Sim
Sim
Não
Telefone / Email do Suporte
Sim
Sim
Não
Atendimento Prioritário
Sim
Sim
Não
Visitas de Emergências*
Sim
Sim
Não
Inclui peças
Sim
Não
Não
Suporte Técnico e Software
Sim
Sim
Sim
IQ/OQ (Farma)***
Sim
Sim
Sim

*inclui diárias & gastos de viagem***disponível por um custo adicional

Contatar suporte