As an essential part of numerous chemical processes, many catalysts contain valuable materials such as precious metals and nanomaterials. Catalyst dosing and activity tuning are essential for achieving the best product quality using minimum reaction time and process energy. XRD, XRF and NIR are essential tools for monitoring and controlling the fabrication and use of catalytic materials.

Typical applications include

  • In situ catalytic activity measurements
  • Phase analysis of heterogeneous catalysts
  • Nanoparticle size and shape analyses
  • Elemental composition of the catalysts during production and usage
  • Trace element analysis of doped catalysts
  • Catalyst poisoning
  • Fines and attrition determination

Characterization of catalysts and nanomaterials

Malvern Panalytical’s Empyrean XRD platform can be equipped with an Anton Paar high-pressure chamber for in situ activity measurements of catalysts, allowing catalyst optimization under the widest range of process conditions saving you time and money. Along with small-angle X-ray scattering (SAXS), this combination of platforms is perfectly suited for analyzing nanoparticle sizes and shapes. The pre-aligned fast interchangeable PreFIX modules can modify a typical XRD setup to a SAXS setup for nanomaterials analyses in approximately 5 minutes.

The CubiX³ is a robust XRD system and the fastest industrial diffractomer in its class for more routine analysis of your catalytic materials.

Zetium XRF systems provide accurate elemental analysis of both hetero- and homogenous catalysts. For example the determination of heavy metal concentrations by Zetium provides a cost-effective and efficient alternative to fire assay determination of precious metals. 

Linha Mastersizer

Linha Mastersizer

Os analisadores de tamanho de partículas mais utilizados no mundo.

Mais detalhes
Medição Tamanho da partícula
Faixa de tamanho das partículas: 0.01µm - 3500µm
Tecnologia Difração laser
Tipo de dispersão Via úmida, A seco, Via úmida e a Seco

Variedades do Empyrean

Variedades do Empyrean

A solução multifuncional para suas necessidades analíticas

Mais detalhes
Medição Forma da partícula, Tamanho da partícula, Crystal structure determination, Identificação de fase, Phase quantification, Contaminant detection and analysis, Epitaxy analysis, Interface roughness, 3D structure / imaging
Configuração de Goniômetro Vertical goniometer, Θ-Θ
Tecnologia X-ray Diffraction (XRD)

Zetium

Zetium

Excelência elementar

Mais detalhes
Medição Identificação química, Metrologia de filme fino, Elemental analysis, Contaminant detection and analysis, Elemental quantification
Gama elementar Be-U
Resolução (Mg-Ka) 35eV
LLD 0.1 ppm - 100%
processamento de amostra 160per 8h day - 240per 8h day
Tecnologia Wavelength Dispersive X-ray Fluorescence (WDXRF), Energy Dispersive X-ray Fluorescence (EDXRF)

Linha Mastersizer

Linha Mastersizer

Os analisadores de tamanho de partículas mais utilizados no mundo.

Variedades do Empyrean

Variedades do Empyrean

A solução multifuncional para suas necessidades analíticas

Zetium

Zetium

Excelência elementar

Mais detalhes Mais detalhes Mais detalhes
Medição Tamanho da partícula Forma da partícula, Tamanho da partícula, Crystal structure determination, Identificação de fase, Phase quantification, Contaminant detection and analysis, Epitaxy analysis, Interface roughness, 3D structure / imaging Identificação química, Metrologia de filme fino, Elemental analysis, Contaminant detection and analysis, Elemental quantification
Faixa de tamanho das partículas: 0.01µm - 3500µm    
Configuração de Goniômetro   Vertical goniometer, Θ-Θ  
Gama elementar     Be-U
Resolução (Mg-Ka)     35eV
LLD     0.1 ppm - 100%
processamento de amostra     160per 8h day - 240per 8h day
Tecnologia Difração laser X-ray Diffraction (XRD) Wavelength Dispersive X-ray Fluorescence (WDXRF), Energy Dispersive X-ray Fluorescence (EDXRF)
Tipo de dispersão Via úmida, A seco, Via úmida e a Seco    

Linha Mastersizer

Variedades do Empyrean

Zetium

Linha Mastersizer Variedades do Empyrean Zetium

Os analisadores de tamanho de partículas mais utilizados no mundo.

A solução multifuncional para suas necessidades analíticas

Excelência elementar

Mais detalhes Mais detalhes Mais detalhes
Tecnologia
Difração laser
X-ray Diffraction (XRD)
X-ray Imaging
Energy Dispersive X-ray Fluorescence (EDXRF)
Wavelength Dispersive X-ray Fluorescence (WDXRF)