| 00:00:00 | FPIA 3000: Setting the standard for SiC size & shape measurements for solar PV applications | 
| 00:01:54 | FPIA 3000: Setting the standard for SiC size and shape measurements for solar PV applications | 
| 00:02:15 | Overview | 
| 00:03:19 | Introduction to the FPIA-3000 | 
| 00:04:08 | Introduction to the FPIA-3000 Basic principles of wet-dynamic image analysis | 
| 00:04:44 | Introduction to the FPIA-3000 | 
| 00:05:31 | Introduction to the FPIA-3000 | 
| 00:05:48 | Sheath flow cell mechanism | 
| 00:06:18 | Introduction to the FPIA-3000 | 
| 00:06:41 | Introduction to the FPIA-3000 | 
| 00:06:55 | Video Demonstration | 
| 00:06:55 | Magnification Options | 
| 00:08:00 | Saint-Gobain Ceramic Materials in Norway | 
| 00:08:42 | Saint-Gobain Ceramic Materials | 
| 00:09:00 | SiC in PV industry | 
| 00:09:35 | Characterization of SiC | 
| 00:10:21 | Method optimization for circularity | 
| 00:11:00 | Criteria improved | 
| 00:11:28 | Pictures of raw data from Sysmex FPIA-3000 with old ultrasonic settings and mass: | 
| 00:11:38 | Pictures of raw data from Sysmex FPIA-3000 with reduced ultrasonic settings and mass: | 
| 00:11:48 | Explanation for use of convexity filter instead of circularity | 
| 00:12:44 | Pictures of particles who were deleted with old SOP (< 0,7 in circ) | 
| 00:12:59 | Pictures of particles who is deleted with new SOP (< 0,92 in convexity) | 
| 00:13:23 | Increase valid pixel from 5 to 20 | 
| 00:14:02 | Suggestions | 
| 00:14:22 | Change in level particles below 5 micron number based | 
| 00:14:53 | The calculation set points, history | 
| 00:15:43 | The calculation set points, today: | 
| 00:16:23 | The calculation set point, future: | 
| 00:16:55 | Effect on fixed PSD for calculation | 
| 00:17:25 | Round Robin test | 
| 00:18:50 | SiC Sample preparation and analysis on the FPIA-3000 | 
| 00:20:02 | SiC Sample preparation and analysis on the FPIA-3000 | 
| 00:22:43 | SiC Sample preparation and analysis on the FPIA-3000 | 
| 00:23:15 | Video Demonstration | 
| 00:23:15 | SiC Sample preparation and analysis on the FPIA-3000 | 
| 00:23:42 | SiC Sample preparation and analysis on the FPIA-3000 | 
| 00:26:27 | SiC Sample preparation and analysis on the FPIA-3000 | 
| 00:28:49 | SiC Sample preparation and analysis on the FPIA-3000 | 
| 00:29:49 | SiC Sample preparation and analysis on the FPIA-3000 | 
| 00:30:34 | SiC Sample preparation and analysis on the FPIA-3000 | 
| 00:31:05 | SiC Sample preparation and analysis on the FPIA-3000 | 
| 00:31:50 | SiC Sample preparation and analysis on the FPIA-3000 | 
| 00:32:01 | Software Demonstration | 
| 00:32:01 | Daily Maintenance | 
| 00:35:17 | Daily Maintenance – 20X LPF Auto focus - Good | 
| 00:35:39 | Daily Maintenance – 20X LPF Auto focus - Bad | 
| 00:36:01 | Circularity Specifications on Latex Standards | 
| 00:37:23 | Invitation to participate in a round robin to set the standards | 
| 00:38:57 | Invitation to participate in a round robin to set the standards | 
| 00:40:39 | Contact Information | 
        This webinar discusses the practical requirements for standardizing size and shape measurements of SiC abrasives used in the manufacture of solar photovoltaic cells.