Microfluidic chip price
There are a range of microfluidic chip prices, depending on the type of chip and its features.
One of the biggest factors determining the cost of a microfluidic chip – and ultimately, its cost of use – is reusability. Some devices – such as COVID-19 self-tests – use single-use chips, which cannot be reused once the microfluidic channels have been filled with a sample. Other chips, such as those used in optical biosensors, allow you to measure more than one sample per channel. This typically makes both device and microfluidic chip cost more.
Our no-clog KYMAchips can often be used repeatedly. How many times depends on the experimental set-up and surface chemistry, including ligand stability, sample composition, buffers, and surface chemistry. For instance, if your ligand is not very stable or if your sample contains other molecules that interact with the surface, you may not be able to test a high number of samples or take repeat measurements. In addition, it’s possible to regenerate and recapture ligand proteins multiple times with Ni-NTA and Protein A/G chips.
Microfluidic chip prices also depend on the material from which the chips are made, and whether there’s a matrix coating the surface. Some experiments require buffers that might otherwise erode the chip, which means the chip has to be made of materials with high chemical resistance. And chips for optical biosensors can require a coating, which then needs to be compatible with the ligand to allow immobilization for measurements of binding kinetics and affinity.
Cada tipo de chip microfluídico es compatible con diferentes objetivos, etiquetas, relaciones objetivo:analito y matrices. Para obtener una descripción general sobre la compatibilidad de nuestros WAVEchips, consulte las tablas que aparecen a continuación. O, para confirmar que está eligiendo el chip microfluídico adecuado para las necesidades de su aplicación, comuníquese con nosotros.
| Proteína | Anticuerpo | Proteína de membrana | Ligando con carga negativa | Liposomas, vesículas, partículas orgánicas autoensambladas | VLP/partículas grandes | |
|---|---|---|---|---|---|---|
| 4PCH WAVEchip | ✔ | ✔ | ✔ | |||
| 4PCH-STA WAVEchip | ✔ | ✔ | ✔ | |||
| 4PCH-NTA WAVEchip | ✔ | ✔ | ✔ | |||
| 4PCP WAVEchip | ✔ | ✔ | ✔ | ✔ | ✔ | |
| 4PCP-STA WAVEchip | ✔ | ✔ | ✔ | ✔ | ✔ | |
| 4PCP-NTA WAVEchip | ✔ | ✔ | ✔ | ✔ | ✔ | |
| 4PCP-PAG WAVEchip | ✔ | ✔ | ||||
| 4PCP-LIP WAVEchip | ✔ | ✔ | ✔ | ✔ | ✔ | |
| 4PCZ WAVEchip | ✔ | ✔ | ✔ | ✔ | ||
| 4DXH-STA WAVEchip | ✔ | ✔ | ✔ |
| Aminocovalente | Histidina | Estreptavidina | IgG | Etiquetado de celdas de flujo | Lípido | |
|---|---|---|---|---|---|---|
| 4PCH WAVEchip | ✔ | |||||
| 4PCH-STA WAVEchip | ✔ | |||||
| 4PCH-NTA WAVEchip | ✔ | |||||
| 4PCP WAVEchip | ✔ | |||||
| 4PCP-STA WAVEchip | ✔ | |||||
| 4PCP-NTA WAVEchip | ✔ | |||||
| 4PCP-PAG WAVEchip | ✔ | ✔ | ||||
| 4PCP-LIP WAVEchip | ✔ | |||||
| 4PCZ WAVEchip | ✔ | |||||
| 4DXH-STA WAVEchip | ✔ |
| <99:1 | De 100:1 a 350:1 | >350:1 | |
|---|---|---|---|
| 4PCH WAVEchip | ✔ | ✔ | ✔ |
| 4PCH-STA WAVEchip | ✔ | ✔ | ✔ |
| 4PCH-NTA WAVEchip | ✔ | ✔ | ✔ |
| 4PCP WAVEchip | ✔ | ||
| 4PCP-STA WAVEchip | ✔ | ||
| 4PCP-NTA WAVEchip | ✔ | ||
| 4PCP-PAG WAVEchip | ✔ | ||
| 4PCP-LIP WAVEchip | ✔ | ||
| 4PCZ WAVEchip | ✔ | ✔ | ✔ |
| 4DXH-STA WAVEchip | ✔ | ✔ | ✔ |
| Amortiguador | Amortiguador con detergente (alta concentración) | Mezcla de reacción cruda | Suero y plasma | |
|---|---|---|---|---|
| 4PCH WAVEchip | ✔ | ✔ | ✔ | |
| 4PCH-STA WAVEchip | ✔ | ✔ | ✔ | |
| 4PCH-NTA WAVEchip | ✔ | ✔ | ✔ | |
| 4PCP WAVEchip | ✔ | ✔ | ✔ | |
| 4PCP-STA WAVEchip | ✔ | ✔ | ✔ | |
| 4PCP-NTA WAVEchip | ✔ | ✔ | ✔ | |
| 4PCP-PAG WAVEchip | ✔ | ✔ | ✔ | |
| 4PCP-LIP WAVEchip | ✔ | ✔ | ||
| 4PCZ WAVEchip | ✔ | ✔ | ||
| 4DXH-STA WAVEchip | ✔ | ✔ | ✔ |