Why choose the Mastersizer 3000?

The Mastersizer range has been trusted by scientists for generations. And the Mastersizer 3000 range has been developed with a deep understanding of real-world use, resulting in the most advanced and user-friendly particle analyzer in the world. What makes the Mastersizer 3000 special is:

  • Measures a large sample size range
    Incredibly versatile, the 3000 accurately measures particles from 10nm up to 3.5mm

  • Switches easily between wet and dry dispersions
    The ergonomic, easy-to-use  accessories make it easy to load liquids and powders, switch between the two, and prep and clean quickly

  • Data how you want it, with customizable reporting
    Flexible reporting means you get your data how you need it and can integrate them simply and seamlessly into your workflows

  • Intuitive software with ‘built-in expertise’
    The easy-to-use software also monitors your data quality, flagging potential issues (such as insufficient sample quantity, or if the instrument needs cleaning)

  • Compact. Well designed. Easy to use
    The 3000 is no ‘big beige box’. It’s been ergonomically designed to be as space-saving as possible and simple to load, use, clean and service

Understanding your Mastersizer 3000

Particles are too small to measure directly – but by firing a laser beam at a sample and measuring the intensity of the light that gets ‘scattered’, we can accurately calculate a particle’s size. The Mastersizer 3000 is the world’s fastest, most accurate and most reliable instrument for doing this.

There are three key components: the optical bench that houses the laser and detectors; the sample dispersion units where you load samples for analysis; and the user-friendly software that helps you run, report and interpret your data.

  • Optical bench and laser
    This is the heart of the Mastersizer, housing the laser and detectors which measure particles from 10nm to 3.5mm. It uses both red and blue light sources, and captures measurements across a wide range of angles

  • Sample dispersion units
    The dispersion units deliver samples consistently and in the correct concentration. There are six wet dispersion units to handle the widest possible range of sample volumes and dispersants, and a dry dispersant system that handles rapid powder dispersion, even for fragile materials

  • Intuitive software with ‘built-in expertise’
    the user interface makes using the Mastersizer fast and simple, without the need for extensive training. It guides you through every stage, integrates seamlessly with your workflows, and quality checks your measurements, flagging potential quality control issues (such as insufficient sample size or need for cleaning)


What customers use the Mastersizer 3000 for 

The Mastersizer 3000 lets users find the particle size ‘sweet spot’ for a vast array of processes – helping them create substances that behave more predictably, more safely and to a higher quality. Mastersizers are frequently used for:

  • Creating smooth-flowing powders
    Many manufacturing processes need powders to flow smoothly. ¬¬(Too small and flow is unpredictable; too large and the density of final products can be affected). It’s important for processes such as ‘additive’ manufacturing (like 3D-printing), and controlling the quality of sintered products

  • Packing powders to the right density
    The way particles pack together depends on both their size, and the mix of differently-sized particles. Getting the balance right means denser packing. It’s essential for mould-based manufacturing (eg ceramic and metal components) as well as for processes such as powder coating

  • Mixing stable dispersions
    Getting the particle sizes ‘just right’ in dispersions is the difference between creating a stable dispersion with evenly distributed particles, or one with agglomerates (that’s the difference between an even powder coating or smooth-flowing paint, or dispersions with lumps in)

  • Dissolving substances predictably
    Particle size directly affects the speed at which a substance dissolves. (Smaller is faster; larger is slower). This is particularly critical in the pharmaceutical industry, where this affects the release rate of the active components of a drug

  • Controlling how particles are inhaled
    Particle size affects how easy it is for people to inhale substances. In both medicine and industry there are strict guidelines for particle sizes – broadly speaking, so that drugs are quickly and easily inhaled, and harmful substances (such as cleaning products and hairsprays) are not

  • Deciding chemical reaction times
    Particle size determines volume-to-surface-area ratios, which affects chemical reaction times. Controlling reaction times is important in manufacturing processes such as the hardening of cement, and in producing effective catalysts (such as cleaning pollutants from medicines)

  • Manipulating how light reacts with substances
    The particle sizes in pigments, paints and coatings affects how the final products scatter light. So by controlling the particle size, manufacturers can control how bright, strong or glossy something looks

  • Improving the quality of food and drink
    The particle sizes in food and drink can have a dramatic effect on how they smell, taste and feel: the particle size of ground coffee affects is strength and brew time; smaller particles in chocolate make it feel silker and better quality

Especificación

General

Tamaño de partícula:
Suspensions, emulsions, dry powders
Principio:
Laser light scattering
Análisis:
Mie and Fraunhofer scattering
Velocidad de adquisición de datos:
10 kHz
Tiempo típico de medición:
<10 sec
Dimensiones (ancho, fondo, altura):
690mm x 300mm x 450mm
Peso:
30 kg

Optics

Fuente de luz roja:
Max. 4mW He-Ne, 632.8nm
Fuente de luz azul:
Max. 10mW LED, 470nm
Arreglo de lentes:
Reverse Fourier (convergent beam)
Distancia focal efectiva:
300mm

Detector

Arreglo:
Log-spaced array
Rango angular:
0.015 - 144 degrees
alineamiento:
Automatic

Size

Tamaño de partícula:
0.01 - 3500 µm *
Numero de clases de tamaño:
100 (user adjustable)
Precisión:
Better than 0.6% **
Precisión/ Repetibilidad:
Better than 0.5% variation *
Reproducibilidad:
Better than 1% variation *

Software

21 CFR Part 11:
Enables an operating mode that assists with ER/ES compliance

System compliance

Seguridad de laser:
Class 1, IEC60825-1:2007 and CFR Chapter I: Sub-chapterJ: Part 1040 (CDRH)
Pruebas reglamentarias:
RoHS and WEEE compliant CE / FCC compliant Meets requirements of the European Low Voltage directive

System

Potencia:
100/240 v, 50/60 Hz 50W (no dispersion units connected) 200W maximum (2 dispersion units connected)
Humedad:
80% maximum for temperatures up to 31°C, decreasing linearly to 50% at 40°C. Non condensing.
Temperatura de operación (°C):
+5°C to +40°C
Temperatura de almacenamiento de producto:
-20°C to +50°C
Grado de protección (IP):
IP41B

Notes

*:
Sample and sample preparation dependent.
**:
Accuracy defined for the measurement of monomodal latex standards. This specification accounts for the manufacturer’s uncertainty in the latex size. Sample and sample preparation dependant.
Patentes:
The Mastersizer 3000 optical bench is protected by patents; US6,778,271 and related filings; GB2,340,932; together with patents based on applications WO2013038161, WO2013038160 and WO2013038159. Hydro MV and LV protected by EP1167946A2 and related filings.

Accesorios

Sample dispersion accessories for the Mastersizer 3000

Mastersizer 3000

Wet sample dispersion accessories

Hydro Insight

Image

A window into deeper materials analysis

The Hydro Insight is a dynamic imaging accessory that sits alongside the Mastersizer 3000, providing insights that go beyond particle size distribution to particle images and quantitative particle shape data. 

In this way, it helps scientists, researchers, and quality-control managers understand their materials better, develop methods faster, and simplify troubleshooting.

Más información Solicitar cotización

Hydro SV

Image

Dispersión de muestra de vía húmeda de volumen pequeño.

Hydro SV es una unidad de dispersión de líquidos sencilla y económica diseñada para permitir el análisis de tamaño de partícula con volúmenes de muestra y dispersante pequeños.

Más información Solicitar cotización

Hydro MV

Image

Unidad de dispersión automatizada de volumen medio.

El Hydro MV es una unidad de volumen medio para la dispersión de vía húmeda controlada y automatizada de muestras para el análisis de tamaño de partícula. Es adecuado tanto para aplicaciones acuosas como no acuosas; es especialmente útil cuando el tamaño de muestra es limitado o debe minimizarse el uso de dispersantes.

Más información Solicitar cotización

Hydro LV

Image

Dispersión de muestra de vía húmeda de gran volumen.

El Hydro LV es una unidad automatizada de gran volumen que controla la dispersión de vía húmeda de materiales para el análisis de tamaño de partícula. Se adapta muy bien a aplicaciones donde el tamaño de muestra es relativamente grande o la distribución de tamaño es muy amplia.

Más información Solicitar cotización

Hydro EV

Image

Dispersión de vía húmeda de volumen flexible

Una unidad de dispersión de muestra de vía húmeda de inmersión única que puede utilizarse con equipo de vidrio de laboratorio estándar. Adecuado para una amplia variedad de volúmenes de dispersante y rangos de tamaño de partícula.

Más información Solicitar cotización

Hydro SM

Image

Unidad de dispersión de vía húmeda de nivel de entrada de volumen pequeño

Hydro SM es una unidad de dispersión de muestra de vía húmeda económica diseñada para medir muestras de dispersantes no acuosos, donde debe minimizarse el uso de solventes.

Más información Solicitar cotización

Mastersizer 3000 Chocosizer

Image

Control de calidad eficaz para la producción de chocolate

El objetivo de la producción de chocolate es producir un producto con un sabor y una sensación en la boca uniformes, de una manera económica y eficiente. El control del tamaño de partícula y la distribución de tamaño de partícula del cacao y los sólidos de la leche es fundamental para lograr este objetivo. El Mastersizer 3000 Chocosizer está diseñado para apoyar la producción y el control de calidad del chocolate con un método simple para un análisis de tamaño de partícula de chocolate rápido y confiable.

Más información Solicitar cotización

Dry sample dispersion accessories

Aero S

Image

Dispersión de polvo seco de vanguardia

Con un nivel de dispersión de polvo seco sin precedentes, el Aero S se diseñó desde cero con base en la teoría fundamental de dispersión de polvo. El diseño modular garantiza una dispersión rápida y reproducible de la gama más amplia de muestras, desde polvos cohesivos hasta materiales frágiles.

Más información Solicitar cotización

Alimentador de muestra de embudo Aero

Image

Mediciones rápidas de control de calidad para muestras de polvo a granel

El alimentador de muestra de embudo Aero está diseñado para ayudar a los usuarios a lograr mediciones rápidas y reproducibles de tamaño de partícula de polvo seco a granel, y permite que las muestras se agreguen directamente a las unidades de dispersión de polvo seco Aero S y Aero M sin necesidad de abrir la tapa de la unidad de dispersión. Esto acelera y simplifica el proceso de introducción de muestras para el análisis, y reduce el tiempo requerido para obtener resultados.

Más información Solicitar cotización

Support

Proteja su inversión y garantice un desempeño optimizado en todo momento con los planes de servicio de Malvern Panalytical.

Cuando adquiere un producto Malvern Panalytical, comprendemos que se trata solo de la primera etapa de una relación laboral que durará toda la vida útil del instrumento. Según sus necesidades, Malvern Panalytical le proporcionará soporte para su negocio.

Centro de asistencia

Capacitación

Descargas de software

Opciones de servicio de Malvern Panalytical: elija el plan adecuado para sus necesidades

Plan Platinum de Malvern Panalytical

Para laboratorios donde maximizar el tiempo de funcionamiento de los instrumentos es fundamental para el desempeño diario. Nuestro nivel de respuesta más alto: el plan de precios "todo incluido" se hace cargo de los gastos de reparación inesperados en caso de que produzca un incidente desafortunado.

Plan Gold de Malvern Panalytical

Mejore la productividad de su laboratorio manteniendo la eficiencia de los instrumentos. Reciba una respuesta prioritaria, junto con el soporte técnico y de software especializado para mantener el desempeño y la productividad de sus instrumentos.

Bronze Visit de Malvern Panalytical

El mantenimiento preventivo regular es esencial para los laboratorios que desean optimizar el desempeño de los instrumentos.

Plan PlatinumPlan GoldBronze Visit
Prueba PM/PV anual
no
Soporte telefónico y por correo electrónico
no
Respuesta prioritaria
no
Visitas de reparación de emergencia*
no
Piezas incluidas
no
no
Soporte técnico y de software
IQ/OQ (Pharma)***

*incluye costos de mano de obra y desplazamiento***disponible a un costo adicional

Smart Install

Get your new Mastersizer 3000 up and running faster when you choose to self-install. 

With comprehensive resources to help you quickly and safely set-up and verify the performance of your new instrument, there’s no need to wait for an engineer to do it for you. What’s more, self-install presents a new training opportunity as you receive full access to exclusive training material. 

How does it work?

When you follow the step-by-step video instructions, you could be up and running within 90 minutes of delivery of your new Mastersizer 3000. 

You don't need any specific skills or knowledge to perform a self-installation. Simply follow the instructions provided. 

Everything needed to get started is provided with your new instrument – all you need is an internet connection to access the online training. 

Exclusive e-learning content

Resources to get you up and running quickly and with confidence include:  

  • detailed video guides walk you through installation and set-up;
  • 15-months  access to the Essentials e-learning course, which is provided at no extra cost;
  • a comprehensive user manual.

Find out more about self-install.