| 00:00:00 | Welcome |
| 00:02:05 | How low can you go? New advances in the analysis of low molecular weight polymers by GPC |
| 00:02:46 | Industry: Synthetic polymers |
| 00:03:35 | Synthetic polymer application examples |
| 00:04:58 | The drivers for better characterization |
| 00:05:41 | Why are these scientists using GPC? |
| 00:06:42 | Why are these scientists using GPC? |
| 00:07:58 | Low molecular weight polymers |
| 00:09:39 | OMNISEC |
| 00:10:00 | OMNISEC |
| 00:10:08 | OMNISEC |
| 00:10:57 | Detector module – OMNISEC REVEAL |
| 00:11:38 | Refractive index |
| 00:12:20 | UV/Vis PDA |
| 00:13:08 | Light scattering |
| 00:15:10 | Light Scattering |
| 00:15:54 | Light scattering benefits |
| 00:16:53 | Viscometer |
| 00:17:07 | Viscometer technology |
| 00:17:39 | Viscometer |
| 00:18:23 | OMNISEC Viscometer benefits |
| 00:19:04 | The triple detection pyramid |
| 00:19:39 | Separation module – OMINSEC RESOLVE |
| 00:20:46 | Low molecular weight polymer applications |
| 00:21:24 | PEO standards - RI and RALS 196 to 992,000 Da |
| 00:22:12 | PEO 196 Da by Triple Detection |
| 00:22:44 | Triple Chromatogram of Bisphenol A (MW = 228) |
| 00:23:48 | Triple Chromatogram of Bisphenol A Diglycidyl Ether (MW = 340) |
| 00:24:37 | Example Triple Chromatogram of Polypropylene Glycols |
| 00:25:19 | Summary of Molecular values of Polypropylene Glycols |
| 00:25:58 | Comparison of PPG Samples vs Standards |
| 00:26:59 | Triple Chromatogram of Polycaprolactone A (Mw = 1,800) |
| 00:27:47 | Triple Chromatogram of Polycaprolactone B (Mw = 1,600) |
| 00:27:57 | Example Triple Chromatogram of Silicone Oils (Mw = 44,000) |
| 00:28:50 | Summary |
| 00:29:31 | Thanks for listening…Any questions? |
| 00:33:05 | Contact Information |
Gel Permeation Chromatography (GPC) also known as Size Exclusion Chromatography (SEC), is a very popular analytical tool for polymer characterization. Low molecular weight polymers such as polyols, epoxies and polycaprolactones (amongst others) are used in structural applications as well as for coatings and in drug delivery. However, their low molecular weight makes it very difficult for most GPC/SEC system to detect them and accurately measure their absolute molecular weight accurately.
This webinar introduces our latest multi-detector GPC/SEC system, OMNISEC, and show how its unrivalled light scattering sensitivity overcomes these difficulties and opens up these application areas in ways which was not previously possible with other light scattering systems, bringing absolute molecular weight measurements to this important market.
This webinar introduces our latest multi-detector GPC/SEC system, OMNISEC, and show how its unrivalled light scattering sensitivity overcomes these difficulties and opens up these application areas in ways which was not previously possible with other light scattering systems, bringing absolute molecular weight measurements to this important market.