| 00:00:00 | Welcome |
| 00:00:59 | Particle Sizing Masterclass |
| 00:02:02 | Overview |
| 00:02:49 | What is automated particle imaging? |
| 00:03:28 | Automated Image Analysis: Measurement process |
| 00:04:14 | Image capture and analysis |
| 00:05:25 | Morphological shape descriptors: Elongation |
| 00:06:47 | Morphological shape descriptors: Convexity |
| 00:08:25 | Morphological shape descriptors: Circularity |
| 00:09:38 | Morphological shape descriptors: Intensity |
| 00:11:04 | Morphological shape descriptors: Summary |
| 00:12:26 | Result interpretation: Individual particle detail |
| 00:12:54 | Result interpretation: Scattergram |
| 00:14:21 | Result interpretation: Statistical analysis tools |
| 00:16:27 | How to get good particle shape information |
| 00:16:57 | Sample presentation: Dispersion |
| 00:18:10 | Options for sample dispersion |
| 00:20:42 | Static and dynamic image analysis |
| 00:22:19 | Sample presentation: Particle orientation |
| 00:23:03 | Particle orientation: Simulated example |
| 00:23:37 | Particle orientation: Simulated example |
| 00:24:11 | Case studies |
| 00:24:30 | Processing: Metal injection moulding powders |
| 00:25:32 | Metal injection moulding |
| 00:26:53 | Product performance: Gypsum |
| 00:27:57 | Product performance: Gypsum |
| 00:28:19 | Product performance: Gypsum |
| 00:29:02 | Understanding production processes: Milling |
| 00:30:06 | Understanding product performance: Dissolution |
| 00:31:25 | Monitoring fines in abrasive materials |
| 00:33:24 | Shape analysis of a nasal spray |
| 00:34:53 | Conclusions |
| 00:35:27 | Thank you for your attentionAny questions? |
| 00:46:27 | Contact Information |
In this last webinar in the particle sizing masterclass we won’t actually be talking about particle sizing! We will, in fact, be looking at particle shape.
This is because in some applications particle size may not tell the whole story, and information about particle shape can help to fully understand product performance. In this webinar we will look in more detail at the particle shape information available from image analysis, as well as how to ensure that you get good shape information from your particles.
Finally we will cover some case studies where particle shape information has been used to improve product performance and understand production processes.
This is because in some applications particle size may not tell the whole story, and information about particle shape can help to fully understand product performance. In this webinar we will look in more detail at the particle shape information available from image analysis, as well as how to ensure that you get good shape information from your particles.
Finally we will cover some case studies where particle shape information has been used to improve product performance and understand production processes.