Tight control of every step in production process is of utmost importance for achieving the maximum efficiency and quality of cement. From stock pile management, production of raw meal, preparation of kiln feed and the production of clinker right through to the final mixing of the end product the control is driven by the elemental, mineralogical composition and particle size analysis.

The latest demands on CO2 emissions drive the use of alternative fuels and the production of blended cements using supplementary cementitious materials like slag, fly-ash, pozzolan or silica fume. Here, elemental and mineralogical analyses of the intermediate and final products as well as fuels become even more important, while accurate and precise measurement of fineness is critical for optimal grinding. This requires reliable and rugged solutions for steering the process in the most cost-effective way for the highest quality cement or concrete. Malvern Panalytical offers solutions that meet these demands and seamlessly integrate into the production process.

With our cement industry and application knowledge, Malvern Panalytical instruments enable:

  • Control of mill operation through analysis of composition and fineness of raw mill feed
  • Check of mill operation through quality control of raw meal
  • Check of composition and material balances (e.g. K, Na, S, Cl) through filter/ESP dust analysis
  • Identify causes for coating formation
  • Kiln feed analysis through consistency check between raw mill product, kiln feed and clinker analyses, material balances (e.g. K, Na, S, Cl), silo blending efficiency, burnability, heat consumption
  • Analysis of cyclone samples / hot meal samples to check dust separation efficiencies, and degree of calcination, material balances (e.g. K, Na, S, Cl), silo blending efficiency, fuel burn–out
  • Check of coal mill operation, fuel consumption, ash absorption in clinker, material balances (e.g. K, Na, S, Cl), burn–out in calciner, NOx –formation
  • Check fuel consumption, sulphur absorption in clinker, material balances (e.g. K, Na, S, Cl) and NOx –formation
  • Clinker analysis to check kiln operation and clinker quality and material balances (e.g. K, Na, S, Cl)
  • Analysis of finished cement to check mill operation, gypsum and SCM additions as well as quality of the finished cement (e.g. EN 197, ASTM C150, ASTM C595 and ASTM C1157).

Insitec 시리즈

Insitec 시리즈

견고하고 안정적인 실시간 입도 분석

자세한 내용은
측정 입자 크기
입도 범위 0.1µm - 2500µm
기술 유형 레이저 회절
분산 유형 습식, 건식, 분무, 습식 및 건식

Mastersizer 시리즈

Mastersizer 시리즈

전 세계에서 가장 널리 사용하는 입도분석기.

자세한 내용은
측정 입자 크기
입도 범위 0.01µm - 3500µm
기술 유형 레이저 회절
분산 유형 습식, 건식, 습식 및 건식

Aeris

Aeris

간편해진 XRD

자세한 내용은
측정 Crystal structure determination, 상 식별, Phase quantification
X 선관 음극 재료 Cu /Co (option)
기술 유형 X-ray Diffraction (XRD)

CNA range

CNA range

Online elemental analyzers for effective control of many industrial processes

자세한 내용은
측정 입자의 화학적 성분, Elemental analysis, Contaminant detection and analysis, Elemental quantification
정확도 1% (비응축)
기술 유형 PFTNA(Pulsed Fast and Thermal Neutron Activation)

Zetium

Zetium

구성요소의 탁월함

자세한 내용은
측정 박막 계측학, Elemental analysis, Contaminant detection and analysis, Elemental quantification
원소 범위 Be-U
해상도(Mg-Ka) 35eV
LLD 0.1 ppm - 100%
샘플 처리량 160per 8h day - 240per 8h day
기술 유형 Wavelength Dispersive X-ray Fluorescence (WDXRF), Energy Dispersive X-ray Fluorescence (EDXRF)

Insitec 시리즈

Insitec 시리즈

견고하고 안정적인 실시간 입도 분석

Mastersizer 시리즈

Mastersizer 시리즈

전 세계에서 가장 널리 사용하는 입도분석기.

Aeris

Aeris

간편해진 XRD

CNA range

CNA range

Online elemental analyzers for effective control of many industrial processes

Zetium

Zetium

구성요소의 탁월함

자세한 내용은 자세한 내용은 자세한 내용은 자세한 내용은 자세한 내용은
측정 입자 크기 입자 크기 Crystal structure determination, 상 식별, Phase quantification 입자의 화학적 성분, Elemental analysis, Contaminant detection and analysis, Elemental quantification 박막 계측학, Elemental analysis, Contaminant detection and analysis, Elemental quantification
입도 범위 0.1µm - 2500µm 0.01µm - 3500µm      
X 선관 음극 재료     Cu /Co (option)    
정확도       1% (비응축)  
원소 범위         Be-U
해상도(Mg-Ka)         35eV
LLD         0.1 ppm - 100%
샘플 처리량         160per 8h day - 240per 8h day
기술 유형 레이저 회절 레이저 회절 X-ray Diffraction (XRD) PFTNA(Pulsed Fast and Thermal Neutron Activation) Wavelength Dispersive X-ray Fluorescence (WDXRF), Energy Dispersive X-ray Fluorescence (EDXRF)
분산 유형 습식, 건식, 분무, 습식 및 건식 습식, 건식, 습식 및 건식      

Mastersizer 시리즈

Aeris 시멘트 모델

Zetium의 시멘트 에디션

Insitec 시리즈

CNA range

Mastersizer 시리즈 Aeris 시멘트 모델 Zetium의 시멘트 에디션 Insitec 시리즈 CNA range

전 세계에서 가장 널리 사용하는 입도분석기.

시멘트 생산 최적화

시멘트 내 새로운 원소

견고하고 안정적인 실시간 입도 분석

Online elemental analyzers for effective control of many industrial processes

자세한 내용은 자세한 내용은 자세한 내용은 자세한 내용은 자세한 내용은
기술 유형
레이저 회절
X-ray Diffraction (XRD)
Wavelength Dispersive X-ray Fluorescence (WDXRF)
Energy Dispersive X-ray Fluorescence (EDXRF)
PFTNA(Pulsed Fast and Thermal Neutron Activation)