From impurities to catalysts; from crystal structure to characterization of chemicals, we provide essential tools for chemists. Being absolutely sure about which chemical you deal with, and in what phase it is presented, is one of the benefits of using XRD. Particle size and shape analyses are key parameters for processing and end-product qualities in the many chemical industrial applications. In contrast, XRF provides means to determine the elemental composition. For instance, XRF can determine the low-level (mg/kg) elemental impurities or catalyst residues in your products. 

Typical applications include:

  • Phase identification and confirmation 
  • Crystal structure refinement with unrivalled resolution
  • Elemental composition and impurities determination
  • REACH compliance and REACH sameness using full-pattern analysis and cluster analysis to enable the comparison
  • Particle size and shape analysis 
  • Simple yes/no confirmation if you deal with the expected chemicals of for instance everyday incoming goods

REACH compliance

XRD uniquely identifies your (semi-) crystalline chemicals. Malvern Panalytical’s X-ray diffractometers are fast and ideally suited for operator-friendly operation. Moreover it is accurate, simple and fully automated. For example, identification for REACH sameness, is now a simple push-button operation. 

The Empyrean X-ray diffractomer enables the widest range of XRD techniques on one platform. It is ideal for more research-oriented environments including particle shape and size determination possibilities and in situ reaction monitoring. 

Malvern Panalytical’s wavelength dispersive (WD) and energy dispersive (ED) spectrometers belonging to the Zetium and Epsilon 4 respectively, deliver the flexibility and robustness needed to meet the demands for flexibility in the chemicals production environments. The Epsilon 4 range with FingerPrint software for example provides operator-friendly and efficient solutions for quality control. 

Zetasizer 시리즈

Zetasizer 시리즈

나노 입자, 콜로이드, 생체 분자 입자 크기 분석 및 입자 전하 측정 분야에서 전세계적으로 가장 널리 사용되는 시스템

자세한 내용은
측정 분자 크기, 분자량, 입자 크기, 제타 전위
온도 범위 0°C - 120°C
입도 범위 0.3nm - 10µm
기술 유형 광 산란, 동적 광산란, 전기영동 광산란, 정적 광산란
분산 유형 습식
시료 셀 유형 Cuvette
Molecular Measurement Type Chromotography, Batch measurement

Empyrean 범위

Empyrean 범위

각종 분석 수요에 대응하는 다목적 솔루션

자세한 내용은
측정 입자 형상, 입자 크기, Crystal structure determination, 상 식별, Phase quantification, Contaminant detection and analysis, Epitaxy analysis, Interface roughness, 3D structure / imaging
고니오미터 구성 Vertical goniometer, Θ-Θ
기술 유형 X-ray Diffraction (XRD)

Zetium

Zetium

구성요소의 탁월함

자세한 내용은
측정 박막 계측학, Elemental analysis, Contaminant detection and analysis, Elemental quantification
원소 범위 Be-U
해상도(Mg-Ka) 35eV
LLD 0.1 ppm - 100%
샘플 처리량 160per 8h day - 240per 8h day
기술 유형 Wavelength Dispersive X-ray Fluorescence (WDXRF), Energy Dispersive X-ray Fluorescence (EDXRF)

Epsilon 시리즈

Epsilon 시리즈

신속하고 정확한 앳라인 및 온라인 원소 분석

자세한 내용은
측정 박막 계측학, Elemental analysis, Contaminant detection and analysis, Elemental quantification
원소 범위 Na-Am
해상도(Mg-Ka) 145eV
LLD 1 ppm - 100%
샘플 처리량 Up to - 160per 8h day
기술 유형 X-ray Fluorescence (XRF), Energy Dispersive X-ray Fluorescence (EDXRF)

Zetasizer 시리즈

Zetasizer 시리즈

나노 입자, 콜로이드, 생체 분자 입자 크기 분석 및 입자 전하 측정 분야에서 전세계적으로 가장 널리 사용되는 시스템

Empyrean 범위

Empyrean 범위

각종 분석 수요에 대응하는 다목적 솔루션

Zetium

Zetium

구성요소의 탁월함

Epsilon 시리즈

Epsilon 시리즈

신속하고 정확한 앳라인 및 온라인 원소 분석

자세한 내용은 자세한 내용은 자세한 내용은 자세한 내용은
측정 분자 크기, 분자량, 입자 크기, 제타 전위 입자 형상, 입자 크기, Crystal structure determination, 상 식별, Phase quantification, Contaminant detection and analysis, Epitaxy analysis, Interface roughness, 3D structure / imaging 박막 계측학, Elemental analysis, Contaminant detection and analysis, Elemental quantification 박막 계측학, Elemental analysis, Contaminant detection and analysis, Elemental quantification
온도 범위 0°C - 120°C      
입도 범위 0.3nm - 10µm      
고니오미터 구성   Vertical goniometer, Θ-Θ    
원소 범위     Be-U Na-Am
해상도(Mg-Ka)     35eV 145eV
LLD     0.1 ppm - 100% 1 ppm - 100%
샘플 처리량     160per 8h day - 240per 8h day Up to - 160per 8h day
기술 유형 광 산란, 동적 광산란, 전기영동 광산란, 정적 광산란 X-ray Diffraction (XRD) Wavelength Dispersive X-ray Fluorescence (WDXRF), Energy Dispersive X-ray Fluorescence (EDXRF) X-ray Fluorescence (XRF), Energy Dispersive X-ray Fluorescence (EDXRF)
분산 유형 습식      
시료 셀 유형 Cuvette      
Molecular Measurement Type Chromotography, Batch measurement      

Zetasizer 시리즈

Empyrean 범위

Zetium

Epsilon 시리즈

Zetasizer 시리즈 Empyrean 범위 Zetium Epsilon 시리즈

나노 입자, 콜로이드, 생체 분자 입자 크기 분석 및 입자 전하 측정 분야에서 전세계적으로 가장 널리 사용되는 시스템

각종 분석 수요에 대응하는 다목적 솔루션

구성요소의 탁월함

신속하고 정확한 앳라인 및 온라인 원소 분석

자세한 내용은 자세한 내용은 자세한 내용은 자세한 내용은
기술 유형
광 산란
동적 광산란
전기영동 광산란
X-ray Diffraction (XRD)
X-ray Imaging
Energy Dispersive X-ray Fluorescence (EDXRF)
Wavelength Dispersive X-ray Fluorescence (WDXRF)