Fecha registrada: June 12 2019

Duration: 52 minutes 55 seconds

Always wanted to know about which analytical techniques that are most suitable for what types of materials characterization? Join our webinar by Dr Nicholas Norberg who is an application specialist in Malvern Panalytical’s supply center. He discusses methodologies like NIR and XRD in the context of stringent monitoring of low quantity respirable silica and asbestos – from as low as 0.1%. He will be able to provide more insight on the plus points and limitations for the identification, quantification and adherence to EPA and ISO norms.

Join this webinar if you want to have a better general understanding of the materials characterization methodologies. Join us too if you are a supplier and manufacturer, as it is an obligation to ensure safe working conditions for employees and safe-to-use products for consumers. Related companies include government agencies dealing with environmental monitoring, mine sites, cement plants or product manufacturing including construction, paint, paper, insulation, vehicle parts, cosmetics and more. 

Upholding a safe workplace environment is critical. Learn also about the exposure points to respirable silica and asbestos in our blog article here

Table of contents
1. Controlling respirable silica and asbestos in your mine or product manufacturing
02:27
2. Contact Information
00:00
3. Controlling respirable silica and asbestos in your mine or product manufacturing
00:13
4. Content
00:58
5. Introduction
00:14
6. Introduction
03:27
7. Introduction
01:02
8. Introduction
00:46
9. Introduction
00:52
10. Introduction
01:06
11. Introduction
01:01
12. Introduction
00:55
13. Introduction
00:52
14. Introduction
00:35
15. Introduction
01:02
16. XRD – Equipment, sample preparation & Analysis
00:13
17. XRD equipment
00:48
18. XRD equipment
00:40
19. XRD equipment
00:42
20. XRD equipment
00:28
21. XRD equipment
00:21
22. XRD equipment
00:17
23. XRD equipment
00:25
24. XRD equipment
00:21
25. XRD equipment
00:47
26. XRD equipment
00:28
27. Sample Preparation
00:29
28. Sample Preparation
00:42
29. Sample Preparation
00:59
30. XRD analysis
01:15
31. XRD analysis
00:35
32. XRD analysis
00:24
33. XRD analysis
00:15
34. XRD analysis
00:34
35. XRD analysis
00:53
36. XRD analysis
00:35
37. XRD analysis
00:20
38. XRD analysis
00:40
39. XRD analysis
00:16
40. XRD analysis
00:14
41. XRD analysis
00:13
42. XRD analysis
00:23
43. XRD analysis
00:30
44. Application examples
00:16
45. Asbestos in talc
00:59
46. Talc in Asbestos
00:11
47. Asbestos in talc
00:32
48. Asbestos in talc
00:48
49. Asbestos in talc
00:27
50. Asbestos in filters
00:40
51. Asbestos in filters - chrysotile
00:30
52. Asbestos in filters - chrysotile
00:25
53. Asbestos in filters - chrysotile
00:49
54. Asbestos in filters - chrysotile
00:27
55. Asbestos in filters - chrysotile
00:20
56. Asbestos in filters - chrysotile
00:16
57. Asbestos in filters - amosite
00:42
58. Asbestos in filters - amosite
00:14
59. Respirable silica
00:30
60. Respirable silica
00:31
61. Respirable silica
00:12
62. Respirable silica
00:26
63. Summary & Conclusion
00:08
64. Concluding remarks
01:00
65. Concluding remarks
00:39
66. Thank you for your attention!Questions?
11:36