From impurities to catalysts; from crystal structure to characterization of chemicals, we provide essential tools for chemists. Being absolutely sure about which chemical you deal with, and in what phase it is presented, is one of the benefits of using XRD. Particle size and shape analyses are key parameters for processing and end-product qualities in the many chemical industrial applications. In contrast, XRF provides means to determine the elemental composition. For instance, XRF can determine the low-level (mg/kg) elemental impurities or catalyst residues in your products. 

Typical applications include:

  • Phase identification and confirmation 
  • Crystal structure refinement with unrivalled resolution
  • Elemental composition and impurities determination
  • REACH compliance and REACH sameness using full-pattern analysis and cluster analysis to enable the comparison
  • Particle size and shape analysis 
  • Simple yes/no confirmation if you deal with the expected chemicals of for instance everyday incoming goods

REACH compliance

XRD uniquely identifies your (semi-) crystalline chemicals. Malvern Panalytical’s X-ray diffractometers are fast and ideally suited for operator-friendly operation. Moreover it is accurate, simple and fully automated. For example, identification for REACH sameness, is now a simple push-button operation. 

The Empyrean X-ray diffractomer enables the widest range of XRD techniques on one platform. It is ideal for more research-oriented environments including particle shape and size determination possibilities and in situ reaction monitoring. 

Malvern Panalytical’s wavelength dispersive (WD) and energy dispersive (ED) spectrometers belonging to the Zetium and Epsilon 4 respectively, deliver the flexibility and robustness needed to meet the demands for flexibility in the chemicals production environments. The Epsilon 4 range with FingerPrint software for example provides operator-friendly and efficient solutions for quality control. 

Gamme Zetasizer

Gamme Zetasizer

Les systèmes les plus utilisés au monde pour les mesures de la taille et de la charge des nanoparticules, des colloïdes et des particules biomoléculaires

Plus de détails
Mesure Taille moléculaire, Masse molaire, Taille des particules, Potentiel zêta
Plage de température 0°C - 120°C
Gamme de tailles des particules : 0.3nm - 10µm
Technologie Lumière diffusée, Diffusion dynamique de la lumière, Électrophorèse laser Doppler, Diffusion statique de la lumière
Type de dispersion Liquide
Type de cellules de mesure d'échantillon Cuvette
Molecular Measurement Type Chromotography, Batch measurement

Gamme Empyrean

Gamme Empyrean

La solution polyvalente pour tous vos besoins d'analyse

Plus de détails
Mesure Forme des particules, Taille des particules, Crystal structure determination, Identification de phase, Phase quantification, Contaminant detection and analysis, Epitaxy analysis, Interface roughness, 3D structure / imaging
Configuration du goniomètre Vertical goniometer, Θ-Θ
Technologie X-ray Diffraction (XRD)

Zetium

Zetium

L'excellence élémentaire

Plus de détails
Mesure Métrologie des couches minces, Elemental analysis, Contaminant detection and analysis, Elemental quantification
Plage élémentaire Be-U
Résolution (Mg-Ka) 35eV
LLD 0.1 ppm - 100%
Débit d'échantillon 160per 8h day - 240per 8h day
Technologie Wavelength Dispersive X-ray Fluorescence (WDXRF), Energy Dispersive X-ray Fluorescence (EDXRF)

Gamme Epsilon

Gamme Epsilon

Analyse élémentaire rapide et précise de et en ligne

Plus de détails
Mesure Métrologie des couches minces, Elemental analysis, Contaminant detection and analysis, Elemental quantification
Plage élémentaire Na-Am
Résolution (Mg-Ka) 145eV
LLD 1 ppm - 100%
Débit d'échantillon Up to - 160per 8h day
Technologie X-ray Fluorescence (XRF), Energy Dispersive X-ray Fluorescence (EDXRF)

Gamme Zetasizer

Gamme Zetasizer

Les systèmes les plus utilisés au monde pour les mesures de la taille et de la charge des nanoparticules, des colloïdes et des particules biomoléculaires

Gamme Empyrean

Gamme Empyrean

La solution polyvalente pour tous vos besoins d'analyse

Zetium

Zetium

L'excellence élémentaire

Gamme Epsilon

Gamme Epsilon

Analyse élémentaire rapide et précise de et en ligne

Plus de détails Plus de détails Plus de détails Plus de détails
Mesure Taille moléculaire, Masse molaire, Taille des particules, Potentiel zêta Forme des particules, Taille des particules, Crystal structure determination, Identification de phase, Phase quantification, Contaminant detection and analysis, Epitaxy analysis, Interface roughness, 3D structure / imaging Métrologie des couches minces, Elemental analysis, Contaminant detection and analysis, Elemental quantification Métrologie des couches minces, Elemental analysis, Contaminant detection and analysis, Elemental quantification
Plage de température 0°C - 120°C      
Gamme de tailles des particules : 0.3nm - 10µm      
Configuration du goniomètre   Vertical goniometer, Θ-Θ    
Plage élémentaire     Be-U Na-Am
Résolution (Mg-Ka)     35eV 145eV
LLD     0.1 ppm - 100% 1 ppm - 100%
Débit d'échantillon     160per 8h day - 240per 8h day Up to - 160per 8h day
Technologie Lumière diffusée, Diffusion dynamique de la lumière, Électrophorèse laser Doppler, Diffusion statique de la lumière X-ray Diffraction (XRD) Wavelength Dispersive X-ray Fluorescence (WDXRF), Energy Dispersive X-ray Fluorescence (EDXRF) X-ray Fluorescence (XRF), Energy Dispersive X-ray Fluorescence (EDXRF)
Type de dispersion Liquide      
Type de cellules de mesure d'échantillon Cuvette      
Molecular Measurement Type Chromotography, Batch measurement      

Gamme Zetasizer

Gamme Empyrean

Zetium

Gamme Epsilon

Gamme Zetasizer Gamme Empyrean Zetium Gamme Epsilon

Les systèmes les plus utilisés au monde pour les mesures de la taille et de la charge des nanoparticules, des colloïdes et des particules biomoléculaires

La solution polyvalente pour tous vos besoins d'analyse

L'excellence élémentaire

Analyse élémentaire rapide et précise de et en ligne

Plus de détails Plus de détails Plus de détails Plus de détails
Technologie
Lumière diffusée
Diffusion dynamique de la lumière
Électrophorèse laser Doppler
X-ray Diffraction (XRD)
X-ray Imaging
Energy Dispersive X-ray Fluorescence (EDXRF)
Wavelength Dispersive X-ray Fluorescence (WDXRF)