00:00:00 | Welcome |
00:00:14 | Introduction |
00:00:19 | Dynamic light scattering in 30 Minutes |
00:00:55 | Agenda |
00:01:12 | Agenda |
00:01:15 | Dynamic Light Scattering and Brownian Motion |
00:02:31 | Brownian Motion |
00:03:22 | Hydrodynamic Size |
00:05:13 | DLS Instrument Components |
00:07:35 | Intensity Fluctuations and Brownian Motion |
00:08:11 | Constructive and Destructive Interference |
00:09:58 | Agenda |
00:10:03 | Correlation in Dynamic Light Scattering |
00:11:59 | Correlation |
00:12:44 | Correlation |
00:14:31 | Correlation |
00:15:15 | Correlation |
00:15:44 | Correlation |
00:15:49 | Correlation |
00:16:56 | Correlation |
00:18:01 | Correlation Functions |
00:18:12 | Agenda |
00:18:34 | Correlation Functions |
00:19:43 | Analysing The Correlation Function |
00:19:48 | Analysing The Correlation Function |
00:20:55 | Cumulants Analysis |
00:22:21 | The z-Average Diameter |
00:23:11 | Polydispersity Index |
00:24:27 | Zetasizer Distribution Algorithms |
00:27:18 | Size Distributions in the Zetasizer Software |
00:28:22 | Intensity Size Distributions |
00:29:49 | Volume Size Distributions |
00:31:18 | Number Size Distributions |
00:32:06 | Size Distributions From DLS |
00:32:54 | Volume/Number Distributions: Recommended Use |
00:33:46 | Any Questions? |
Dynamic Light Scattering (DLS), sometimes referred to as Photon Correlation Spectroscopy or Quasi-Elastic Light Scattering, is a technique classically used for measuring the size of particles typically in the sub-micron region, dispersed in a liquid. The sensitivity of some modern systems is such that it can also now be used to measure the size of macromolecules in solution.
In this presentation Dr Mike Kaszuba will summarize how the technique works, what its size and concentration limits are, and discuss its advantages and disadvantages.
Vortragende
Dr Mike Kaszuba: Michael Kaszuba is Technical Support Manager at Malvern Instruments Ltd. He has a PhD from the Polytechnic of Wales, where he studied the physical biochemistry of liposomes using nuclear magnetic resonance techniques. He followed this with postdoctoral research into liposomal drug delivery at the University of Manchester. Michael joined Malvern in 1996 as a Product Technical Specialist and two years later was appointed in his current role, responsible for the Product Technical Specialist and Application groups based in the UK.
Weitere Informationen
Who should attend?
Anyone who is working with or interested in Dynamic Light scattering and would like an overview of the technique including its benefits and limitations.
What will you learn?
About how Dynamic Light Scattering works, including the generation and interpretation of the correlation function and how this is used to give particle size information.
Why attend?
This is an opportunity to get a basic overview of Dynamic Light Scattering and its applications from one of Malvern Panalytical's Zetasizer experts.