Epsilon 3X in automation

Flexible and safe automation for process control

Historically, the automation of X-ray fluorescence (XRF) instruments has been limited to high-power wavelength dispersive (WD)XRF systems. However, more and more benchtop energy dispersive (ED)XRF spectrometers are sold into production control as cost-effective solutions because of improved performance. Recent advances in Epsilon 3X (ED)XRF spectrometers make them an attractive alternative in automated environments.

The Epsilon 3X automation option is a simple and flexible solution interfacing your existing Epsilon 3 or new Epsilon 3X analyzer to any sample preparation equipment. The flexible sample introduction system is specifically designed to handle a variety of prepared samples coming from a belt, a robot or even from a manual input slide.

Demander un devis Demander une démonstration Contact commercial

Features

Easy to integrate Epsilon 3X

New and existing Epsilon 3X spectrometers (with standard lid only) are easily integrated in the field without any modification necessary to the instrument. You will not void any guarantees or legal conformities by putting your Epsilon 3 unit inside the automation cabinet. 

Complete safety 

Prepared samples are picked up from a belt and transferred inside the Epsilon 3X instrument in complete safety. The instrument is enclosed in a sealed cabinet for safe operation and protection against dust, making it extremely robust. The interlocked cabinet door protects the operator from moving components during operation. 

Flexible sample introduction 

Prepared samples can be introduced to the Epsilon 3 instrument in four different ways: 

  • sample on conveyer belt with surface down
  • sample on conveyer belt with surface up (using sample inverter mechanism)
  • via robotic arm (located outside the cabinet)
  • via manual sample slide (through-wall operation).

Support

Équipements

Solutions pour optimiser votre retour sur investissement

Pour garantir que votre instrument reste en parfait état et qu'il fonctionne au plus haut niveau, Malvern Panalytical offre toute une gamme de services. Notre expertise et nos services d'assistance assurent un fonctionnement optimal de votre instrument.

Assistance

Service à vie

  • Assistance téléphonique et à distance
  • Maintenance préventive et contrôles
  • Contrats de service client flexibles
  • Certificat de performances
  • Mises à niveau matérielles et logicielles
  • Assistance locale et mondiale

Expertise

Ajout de valeur à vos procédés 

  • Développement/optimisation de la préparation d'échantillons
  • Méthodes analytiques 
  • Solutions clé en main pour XRD 
  • Opérations via QI/QO/QP, assurance qualité (BPL, ISO17025) ou études d'essais comparatifs/interlaboratoires
  • Automatisation des procédés de laboratoire
  • Services de conseils

Formation et éducation

  • Formation sur site ou dans nos centres de compétence
  • Large gamme de formations élémentaires et approfondies sur les produits, les applications et les logiciels

Services analytiques et matériel d'étalonnage

  • Services d'analyses d'experts (XRF)
  • Analyse d'oxydes et d'éléments traces
  • Matériel d'étalonnage personnalisé