Parsum IPP 70-SL
An intrinsically safe in-line particle sizing probe for real-time measurement
Lightweight and easy to install, the Parsum IPP 70-SL probe, comes in lengths up to 4m and delivers in situ, real-time size and velocity measurements for solid particles up to 6000µm in size. Dustproof and waterproof, the probe is inserted directly into the vessel with no requirement for sampling or calibration. It provides continuous process monitoring at high and fluctuating solids loadings, even for abrasive, greasy or sticky particles.
Manuals and software
Support contract options
Protect your investment and ensure optimized performance at all times with Malvern Panalytical's service plans.
When you purchase a Malvern Panalytical product we understand that this is just the first stage of a working relationship that will last for the lifetime of the instrument. Depending on your needs, Malvern Panalytical will provide the support for your business.
Help Desk
- Telephone and email support.
- Operators who take responsibility for your call and ensure your query is answered.
Training
Software downloads
Malvern Panalytical's service options- choose the right plan for you:
Malvern Panalytical Platinum Plan
For laboratories where maximizing instrument up-time is critical to its daily performance. Our highest level of response and the 'all inclusive' price plan takes care of those unexpected repair bills should the unfortunate occur.
Malvern Panalytical Gold Plan
Enhance your laboratory productivity by maintaining instrument efficiency. Still receive that priority response, combined with specialist technical and software support, we'll keep your instrument performance on track to deliver.
Malvern Panalytical Bronze Visit
For laboratories looking to optimize instrument performance, regular preventative maintenance is essential.
Platinum Plan | Gold Plan | Bronze Visit | |
---|---|---|---|
Annual PM/PV Test | yes | yes | no |
Telephone / Email Support | yes | yes | no |
Priority Response | yes | yes | no |
Emergency Breakdown visits* | yes | yes | no |
Parts Included | yes | no | no |
Technical & Software Support | yes | yes | yes |
IQ/OQ (Pharma)*** | yes | yes | yes |
*including labour & travel costs***available at an additional cost
Accessories
Parsum IPP 70-SL
4 – 20 mA Interface board (8 channels)
Efficient data transfer from Parsum probe to centralized control system.
Parsum’s optional 4-20 mA interface board streamlines the transfer of particle size data from the probe to a centralized control system, for automation or data display. Eight channels allow interfacing with four probes, each installed as far as 100 m away from the analyzer PC.
At-line measurement station
At-line particle sizing for process applications.
Used in combination with Parsum IPP70-S or IPP70-SE probes, the at-line measurement station enables fast, efficient particle sizing of process samples in the laboratory or on the plant.
D12 inline sample disperser
Inline dispersion for coarse particles and high solids loadings.
The D12 sample disperser samples, dilutes and disperses material from a process, simultaneously presenting it for accurate particle size distribution and velocity measurement using the Parsum inline measurement probes. It ensures robust and accurate sizing for coarse particles in processes where solids loadings are high, such as within granulation systems.
D24 inline sample disperser
Inline disperser for fine particle processes
The D24 disperser dilutes and disperses material drawn from the process, simultaneously directing it towards the measurement zone of the Parsum probe. It ensures robust and accurate sizing for particles with a Dv50 in the range 50 µm to 1.2mm, making it especially useful for direct measurement within fluidized beds.