Good practice in using the FPIA-3000

このウェビナーを視聴するにはログインしてください

まだ登録されていませんか? アカウントを作成する
00:00:00 Good Practice In Using The FPIA-3000
00:02:24 Good Practice Guide
00:02:50 Good Practice using the FPIA-3000
00:03:13 Introducing the FPIA-3000
00:04:12 Introducing the FPIA-3000
00:04:35 Introducing the FPIA-3000
00:05:09 Introducing the FPIA-3000 - Sheath flow cell mechanism
00:05:57 Introducing the FPIA-3000 - results
00:06:54 Introducing the FPIA-3000 – Particle images
00:07:05 General Daily Guidelines
00:07:19 General Daily Guidelines - Start up routine for the FPIA-3000
00:09:22 General Daily Guidelines - Shutting down routine for the FPIA-3000
00:09:55 General Daily Guidelines - Sheath Reagents
00:10:47 General daily guidelines sheath reagents
00:11:28 Method development Guidelines
00:11:40 Method development guidelines – Understand the sequence of events
00:12:23 Method development guidelines
00:13:37 Method development guidelines
00:14:00 Method development guidelines
00:14:35 Method development guidelines
00:15:05 Method development guidelines - Representativity
00:15:54 Method development guidelines - Assess sample’s particle size
00:16:36 Method development guidleines - Assess sample wetting
00:17:19 Method development Guidelines - Assess agglomeration
00:17:43 Method development Guidelines - Assess particle density
00:18:01 Method development guidelines – Assess particle transparency
00:18:23 Method development guidelines - Threshold
00:18:59 Method Development guidelines - Threshold
00:19:18 Method Development guidelines - Threshold
00:19:48 Method development guidelines - Threshold
00:19:57 Method development guidelines - Threshold
00:20:11 Method development guidelines
00:20:36 Method development guidelines - Threshold
00:20:57 Method development guidelines - Threshold
00:21:10 Method development guidelines - Threshold
00:21:41 Method development guidelines - Threshold
00:21:59 Method development guidelines - Threshold
00:22:07 Method development guidelines - Threshold
00:22:09 Method development guidelines - Threshold
00:22:14 Method development guidelines - Threshold
00:22:22 Results analysis guidelines
00:22:30 Results analysis guidelines – size ranges
00:23:37 Results analysis guidelines – LPF-HPF merge
00:24:06 Results Analysis Guidelines – no. of pixels
00:25:06 Results Analysis Guidelines – particle count
00:26:15 Results analysis guidelines
00:26:46 Results analysis guidelines
00:27:03 Results analysis guidelines
00:27:41 Results analysis guidelines
00:28:26 Application examples
00:28:32 Application Example - Agglomerates
00:29:22 Application Example - Agglomerates
00:29:43 Application Example - Agglomerates
00:30:05 Application Example - Agglomerates
00:30:23 Application Example– Outlying particles
00:30:35 Application Example– Outlying particles
00:30:49 Application Example– Outlying particles
00:31:11 Application Example – Outlying particles
00:31:25 Application Example – Outlying particles
00:32:10 Application example – Dense samples
00:32:36 Application example – Dense samples
00:32:44 Application example – Dense samples
00:33:35 Application example – Dense samples
00:34:06 Application example – Dense samples
00:34:14 Application example – Dense samples
00:34:45 Contact Information
In this seminar we will give guidlines to help with using the FPIA-3000 automated imaging system for routine particle size and shape anlaysis measurement, including method development and results analysis advice.