Epsilon 4 can be used to save up to $190,000 in the production of oils and fuels. Compliant, repeatable and accurate elemental analysis is a given but additional value is generated in several parts in your refining operation:
Analyses performed by Epsilon 4 comply with international test methods and regulations, like TIER 3, ISO 13032, ISO 20847, ISO 8754, ASTM D4294, ASTM D4929, JIS K2541-4, IP 336 and IP 496.
The power of benchtop XRF: Combining the latest excitation and detection technologies and smart design, the analytical performance of Epsilon 4 approaches that of more powerful and floor-standing spectrometers. Selective excitation and careful matching of the X-ray tube output to the capabilities of the detection system underlie the system’s outstanding performance.
Calibrated for years: A low-drift X-ray tube and an automatic drift correction system give compliant results for years without the need for re-calibration. This results in a more efficient use of the system and less cost of calibration maintenance.
Fast and sensitive: Fast measurements are achieved by using the latest silicon drift detector technology that produces significantly higher intensities. Unique detector electronics enable a linear count rate capacity to over 1,500,000 cps (at 50% dead time) and a count rate independent resolution typically better than 135 eV for better separation of analytical lines in the spectrum. This allows the Epsilon 4 spectrometer to run at full power and therefore realizes a much higher sample throughput compared to traditional EDXRF benchtop instruments.
Reduce helium consumption: The high performance of Epsilon 4 enables many applications to be operated in air atmosphere, without longer overhead time and costs involved for helium or maintenance of vacuum system. When measuring in air, low-energy X-ray photons characteristic of sodium, magnesium and aluminium, are sensitive to variations in air pressure and temperature. Built-in temperature and air-pressure sensors compensate for these environmental variations, ensuring excellent results whatever the weather.
Epsilon 4 complies with international test methods and norms, including:
Epsilon 4 offers excellent performance for elemental analysis in different processes in refineries.
This new and powerful benchtop XRF instrument is well suited for the analysis of sulfur and other trace elements in fuels according to the latest ASTM, EPA, ISO, IP and JIS test methods.
Epsilon 4 spectrometers can handle a large variety of sample types, weighing from a few milligrams to larger bulk samples. Samples can be measured as:
| Sample capacity | 10-position removable sample changer |
|---|---|
| Sample size | Typically 5 ml liquid samples |
| Features | Spinner is included for better accuracy of air filter analysis |
| Features | Metal-ceramic side window for maximum stability
50 micrometers thin beryllium window for high sensitivity for light elements (Na, Mg, Al, Si) |
|---|---|
| Tube setting | Ag anode X-ray tube for best performance of P, S and Cl analysis |
| Detector type | High-resolution silicon drift detector (SDD), typically 135 eV @ Mn-Kα |
|---|---|
| Features | Max count rate of 1,500,000 counts/s at 50% dead time
Thin-entrance detector window for high sensitivity |
| Software |
|
|---|
| Title | Version | Date | Download |
|---|---|---|---|
| {{ row.title }} | {{ row.softwareVersion }} | {{ row.date }} | Download |
Sorry, no manuals are available for this product
| Title | Version | Date | Download |
|---|---|---|---|
| {{ row.title }} | {{ row.softwareVersion }} | {{ row.date }} | Download |
Sorry, no software downloads are available for this product
To assure that your instrument remains in top condition and performs on the highest level, Malvern Panalytical offers a wide range of services. Our expertise and support services assure an optimal functioning of your instrument.
Service for a lifetime
Adding value to your processes
Compliant, repeatable and accurate elemental analysis in a powerful benchtop XRF instrument.