Overview

Value beyond compliance

Epsilon 4 offers excellent performance for elemental analysis in different processes in refineries. This new and powerful benchtop XRF instrument is well suited for the analysis of sulfur and other trace elements in fuels according to the latest ASTM, EPA, ISO, IP and JIS test methods.
Illustrated below are the significant added values achievable by Epsilon 4, which is just a single modest investment.

Refinery PROCESS.jpg

Features

The power of benchtop XRF

Combining the latest excitation and detection technologies and smart design, the analytical performance of Epsilon 4 approaches that of more powerful and floor-standing spectrometers. Selective excitation and careful matching of the X-ray tube output to the capabilities of the detection system underlie the system’s outstanding performance.

The power of benchtop XRF

Guaranteed performance

Epsilon 4 complies with international test methods and norms, like TIER 3, ISO 13032, ISO 20847, ISO 8754, ASTM D4294, ASTM D4929, JIS K2541-4, IP 336 and IP 496.

Guaranteed performance

Calibrated for years

A low-drift X-ray tube and an automatic drift correction system give compliant results for years without the need for re-calibration. This results in a more efficient use of the system and less cost of calibration maintenance.
Calibrated for years

Fast and sensitive

Fast measurements are achieved by using the latest silicon drift detector technology that produces significantly higher intensities.
Unique detector electronics enable a linear count rate capacity to over 1,500,000 cps (at 50% dead time) and a count rate independent resolution typically better than 135 eV for better separation of analytical lines in the spectrum. This allows the Epsilon 4 spectrometer to run at full power and therefore realizes a much higher sample throughput compared to traditional EDXRF benchtop instruments.
Fast and sensitive

Reduce helium consumption

The high performance of Epsilon 4 enables many applications to be operated in air atmosphere, without longer overhead time and costs involved for helium or maintenance of vacuum system. When measuring in air, low-energy X-ray photons characteristic of sodium, magnesium and aluminium, are sensitive to variations in air pressure and temperature. Built-in temperature and air-pressure sensors compensate for these environmental variations, ensuring excellent results whatever the weather.
Reduce helium consumption

Specification

Sample handlingX-ray tubeDetectorSoftware
10-position removable sample changerMetal-ceramic side window for maximum stabilityHigh-resolution, typically 135 eV @ Mn-KαOne flexible calibration for oils and fuels using Oil-Trace
Typically 5 ml liquid samples50 micrometers thin beryllium window for high sensitivity for light elements (Na, Mg, Al, Si)Max. count rate of 1,500,000 counts/s at 50% dead timeElemental screening with Omnian standardless analysis solution
Spinner is included for better accuracy of air filter analysisAg anode X-ray tube for best performance of P, S and Cl analysisThin-entrance detector window for high sensitivityPASS/FAIL analysis with FingerPrint solution

Support

Services

Solutions to maximize the return on your investment

To assure that your instrument remains in top condition and performs on the highest level, Malvern Panalytical offers a wide range of services. Our expertise and support services assure an optimal functioning of your instrument.

Support

Service for a lifetime

  • Phone and remote support
  • Preventive maintenance and checkups
  • Flexible Customer Care Agreements
  • Performance certificates
  • Hardware and software upgrades
  • Local and global support

Expertise

Adding value to your processes 

  • Sample preparation development/optimization
  • Analytical methodologies 
  • Turnkey solutions for XRD 
  • Operations via IQ/OQ/PQ, quality assurance (GLP, ISO17025) or round robins/inter laboratory studies
  • Automation of lab processes
  • Consultancy services

Training and education

  • Training on-site or at our competence centers
  • Broad range of basic and advanced courses on products, applications and software

Analytical services and calibration materials

  • Expert (XRF) analyses services
  • Oxides and trace analysis
  • Customized calibration materials

Key applications

Epsilon 4 spectrometers can handle a large variety of sample types weighing from a few milligrams to larger bulk samples.

Samples can be measured as:

  • Solids
  • Pressed powders
  • Loose powders
  • Liquids
  • Fused beads
  • Slurries
  • Granules
  • Filters
  • Films and coatings