3rd Annual Pharma Conference Jun 11-12 | Kings College, London. Register now

Register now

MicroCal DSC range

The "Gold Standard" for structural stability analysis of biotherapeutics, biological macromolecules and polymers in solution

Download brochure

MicroCal PEAQ-DSC  microcalorimeters are powerful tools that enable characterization of the thermal stability of proteins and other biomolecules, primarily for biopharmaceutical development and manufacture. They are used for general stability studies, for biosimilarity and batch-to-batch comparability assessment, and for the optimization of purification and manufacturing conditions.  MicroCal PEAQ-DSC systems are simple to use, requiring little assay development, and no labeling or immobilization. 

There are two MicroCal PEAQ-DSC Differential Scanning Calorimetry instruments available, both of which are designed for use in the regulated biopharmaceutical environment.  The MicroCal PEAQ-DSC Automated system has an autosampler for hands-free operation, easing the workload of screening large numbers of samples and pre-set cleaning schedules. For instruments located in Biosafety Level 2 (BSL-2) labs, decontamination cleaning protocols are now also enabled. The MicroCal PEAQ-DSC is a manual instrument, which offers equal performance, reproducibility and minimal sample consumption, for laboratories which need to analyze fewer samples.  Both instruments are operated by MicroCal PEAQ-DSC software, containing the following four specialist modules:

  1. PEAQ-Compliance - for 21 CFR Part 11 compliant operation and data analysis
  2. PEAQ-Performance - to ensure optimal system operation 
  3. PEAQ-Smart (including PEAQ-Finder) - for SOP-based operation and automated analysis, and 
  4. PEAQ-Compare - for the direct comparison of DSC thermograms, between molecules and between batches
MicroCal PEAQ-DSC Automated

MicroCal PEAQ-DSC Automated

A fully automated, gold standard stability assay platform for the biotherapeutic industry

MicroCal PEAQ-DSC

MicroCal PEAQ-DSC

The gold standard for structural stability analysis of biotherapeutics, biological macromolecules and polymers in solution.

Measurement type
Label-free analysis
Protein stability
Technology
Differential Scanning Calorimetry (DSC)
Sample throughput Up to - 50per 24h day Up to - 6per 8h day
Temperature range 2°C - 130°C 2°C - 130°C