Morphologi 4-ID delivers detailed component-specific morphological descriptions of particulate blends through Morphologically-Directed Raman Spectroscopy (MDRS). This combines automated particle imaging with Raman spectroscopy in a single, integrated platform, providing the power to unlock complex particle characterization problems.
The instrument software works seamlessly with Wiley’s KnowItAll® Raman Identification Pro software platform to provide rapid identification of your Raman spectra.
Morphologi 4-ID offers an exclusive capability, combining all the benefits of automated static imaging delivered by the Morphologi 4 with chemical identification of individual particles by Raman spectroscopy in a single measurement.
Patented MDRS capability delivers representative component-specific particle size and shape data, delivering full characterization of your sample
All the functionality of the Morphologi 4, combined with a dedicated Raman platform for physical and chemical particle characterization in a single, automated measurement
Automatically measures Raman spectra for hundreds or thousands of particles, saving valuable analyst time
Ability to export spectra in industry-standard format supports unknown component identification using 3rd party spectral libraries
Tight control of laser power and acquisition time enables measurement optimization for a wide range of materials, from weak Raman scatterers to those that are thermally sensitive
Intuitive software ensures suitability for experienced and non-experienced spectroscopists alike
Adaptable workflows enable methods to be tailored to specific user or application requirements.
Select particles for chemical analysis:
| Technology | Static automated imaging |
|---|---|
| Particle size | 0.5 μm – 1300 μm (upper limit may be extended for some applications*)
* Sample and substrate dependent |
| Particle properties measured | Size, shape, transparency, count, location |
| Particle size parameters | Circle equivalent (CE) diameter, length, width, perimeter, area, maximum distance, sphere equivalent (SE) volume, fiber total length, fiber width |
| Particle shape parameters | Aspect ratio, circularity, convexity, elongation, high sensitivity (HS) circularity, solidity, fiber elongation, fiber straightness |
| Particle transparency parameters | Intensity mean, intensity standard deviation |
| Integrated Sample Dispersion Unit | For fully automated dispersion and measurement of dry powders. Manual or SOP control of dispersion pressure, injection time and settling time |
| Illumination | White light LED: brightfield, diascopic and episcopic; darkfield, episcopic |
| Detector | 18 MP; 4912 x 3684 pixel color CMOS array; pixel size 1.25 μm x 1.25 μm |
| Optical system | Nikon CFI 60 brightfield / darkfield system |
| Lens (and particle size range) | 2.5x: 8.5 µm – 1300 µm (nominal)
5x: 4.5 µm – 520 µm (nominal)
10x: 2.5 µm – 260 µm (nominal)
20x: 1.5 µm – 130 µm (nominal)
50x: 0.5 µm – 50 µm (nominal) |
| Size range | 1 μm - 1300 μm* |
|---|---|
| Spectral performance | 150 cm-1 to 2800 cm-1
6 cm-1 resolution measured on an atomic line source. Average of < 8 cm-1 across the range. |
| Wavelength | 785 nm |
| Power output from spectrometer | < 100 mW |
| Power output at sample | > 45 mW at max power |
| Laser spot size | 2 µm at 50x magnification |
| Laser safety | Class 1 |
| Chemical identification method | Raman spectral correlation |
| Dimensions | 810 mm (W) x 520 mm (D) x 685 mm (H)
with carry handles: 1100mm (W) x 520mm (D) x 685mm (H) |
|---|---|
| Weight | 80 kg (88kg including carry handles) |
| Power | 100-240 V ac 50/60 Hz (<100W load) |
Appropriate dispersion of the individual particles and agglomerates within a sample leads to robust and reliable results. Good spatial separation and representative sampling of the particles is required. To achieve this, a number of dispersion options are available with the Morphologi 4-ID.
Easy, reproducible, automated sample dispersion
Morphologi 4-ID comes with an integrated dry powder dispersion unit. It enables simple, reproducible preparation of dry powder samples. A precise amount of sample is dispersed automatically using a unique compressed air dispersion mechanism controlled from within the software, for reproducible dispersions every time.
Optional accessories – for analysis of particles in suspension
A range of instrument accessories supports preparation of samples on microscope slides, in wet suspensions or on filters, extending the capability of the Morphologi 4-ID beyond the characterization of dry sample dispersions. Each accessory fits directly into the automated stage area and is easily selectable in the Morphologi software.
The Morphologi 4-ID measurement procedure can be split into five sections:
Spatial separation of individual particles and agglomerates is critical to robust results. The integrated dry powder disperser makes preparing dry powder samples easy and reproducible. The applied dispersion energy can be precisely controlled, enabling the measurement process to be optimized for a range of material types. Accessories that fit directly in to the Morphologi 4-ID’s automated stage are available for preparing suspended or filtered samples.
The instrument captures images of individual particles by scanning the sample underneath the microscope optics. The Morphologi 4-ID can illuminate the sample from below or above, whilst accurately controlling the light levels.
Use of either the automated ‘Sharp Edge’ segmentation analysis or the manually-controlled thresholding enables the detection of particles and the calculation of a range of morphological parameters for each.
Components and particles of interest are targeted for Raman analysis. Particles can be selectively targeted based on their morphology, or particles representative of the whole sample can be targeted objectively by the Morphologi software.
Advanced graphing and data classification options in the software ensure that extracting the relevant data from the measurement is straightforward, via an intuitive visual interface. Correlation scores to a reference library are calculated for each Raman spectrum acquired, enabling particles to be classified based on their chemistry. The morphological data associated with the particles in each chemical class is used to generate size and shape distributions, delivering component-specific morphological information. Individually-stored grayscale images for each particle are linked to their Raman spectra and provide qualitative verification of the quantitative results.
The Morphologi 4-ID provides value in a wide range of applications, some of which are described below:
Building materials
Cement is a complex mixture of minerals and additives, the component-specific particle properties of which affect final product performance. The capability of the Morphologi 4-ID system to analyze and characterize specific particle populations within a cement blend enables different batches or products to be compared, aiding product development and solving production problems. It brings new insight to conventional cement manufacture and supports industry objectives to incorporate environmentally sustainable replacement materials, such as fly ash and blast furnace slag.
Energy storage/batteries
Morphologi ID systems can support product development and ensure final product quality by providing information on the chemical composition and structure of electrode materials, enabling their correlation with battery performance.
Forensics
Forensic analysis requires physical and chemical information to interpret evidence. Raman spectroscopy is routinely used in forensic investigations and combining this with automated imaging provides enhanced insight into the physical and chemical properties of unknown and complex mixtures, allowing differentiation between morphologically similar substances. The particle size , shape and chemical information delivered by Morphologi systems enables the detection of counterfeit pharmaceuticals or illicit drugs, the identification of contaminant particles in powders, and the examination of soils and other residues from crime scenes to support the investigative process.
Mining and minerals
The morphology of geological deposits helps trace the extent of natural disasters and predict the impact of future environmental events. Particle properties also determine the effectiveness of abrasive minerals for use in cutting and polishing tools. Morphologi automatically generates the statistically relevant, component-specific particle data required to meet these challenges.
Pharmaceutical development
Morphologi ID systems are used by companies across various stages of the pharmaceutical development cycle. The rapid, chemical component-specific morphological information helps to optimize and control both API and excipient particle size and shape during development, and throughout formulation and processing. For generics, this information can be used to simplify and solve deformulation challenges and help establish in vitro bioequivalence. It can also be used to detect anomalies, contaminants and pinpoint process deviations during manufacturing.
OINDP (Orally Inhaled and Nasal Drug Products)
The precise control of particle size and shape is critical in OINDP development and manufacturing, directly impacting drug delivery and efficacy. Morphologi 4-ID provides detailed morphological information of each chemical component, enabling the characterization of active pharmaceutical ingredients (APIs) in formulated blends. This system facilitates the development and optimization of formulations by assessing the impact of blends, processing conditions and devices on the particle size and shape distributions of the API. It supports in-vitro bioequivalence of generic Nasal Spray products through comparison of the API particle properties with the reference product, after actuation. Moreover, it allows for the identification and quantification of foreign particulates, crucial for maintaining product safety and regulatory compliance.
| Title | Version | Date | Download |
|---|---|---|---|
| {{ row.title }} | {{ row.softwareVersion }} | {{ row.date }} | Download |
Sorry, no manuals are available for this product
| Title | Version | Date | Download |
|---|---|---|---|
| {{ row.title }} | {{ row.softwareVersion }} | {{ row.date }} | Download |
Sorry, no software downloads are available for this product
To assure that your instrument remains in top condition and performs on the highest level, Malvern Panalytical offers a wide range of services. Our expertise and support services assure an optimal functioning of your instrument.
Service for a lifetime
Adding value to your processes
All the benefits of automated static imaging, with added particle chemical identification by Raman spectroscopy in a single measurement. Powerful, automated and easy to use particle characterization.