This versatile instrument offers the major benefit of a new enhanced fluorescence detection capability, providing truly holistic analysis. The 6 place fully software-controlled filter wheel means automated analysis of multiple fluorescent markers can be performed without the operator being present, freeing up valuable researcher time.

  • Measure over 1000 particles in just 60 seconds.
  • Particle by particle analysis for high resolution size and concentration.
  • Simultaneous measurement of multiple characteristics, saving time and sample volume.
  • Visual validation of results gives extra confidence.
  • User friendly software with easy set up of SOPs for routine use.
  • Minimal sample preparation.
  • On board temperature control.
  • Choice of laser wavelengths.
  • Up to 6 different filters in a motorized wheel provides flexible fluorescence detection capability.
  • Complies with Industry Standards ISO 19430 and ASTM E 2834:2012   

The Malvern Panalytical NanoSight NS300 uses the technology of Nanoparticle Tracking Analysis (NTA). This unique technology utilizes the properties of both light scattering and Brownian motion in order to obtain the size distribution and concentration measurement of particles in liquid suspension. A laser beam is passed through the sample chamber, and the particles in suspension in the path of this beam scatter light in such a manner that they can easily be visualized via 20x magnification microscope onto which is mounted a camera. The camera operates at 30 frames per second (fps), capturing a video file of the particles moving under Brownian motion. The software tracks many particles individually and using the Stokes-Einstein equation calculates their hydrodynamic diameters

The Malvern Panalytical NanoSight NS300 can be used in many key applications, including:

Extracellular Vesicles (EV) 

Whilst the research into the generation and functions of extracellular vesicles is still evolving, it is important to monitor and control their isolation and purification. NanoSight NTA provides quick and easy characterization of both the size and concentration of vesicles in aqueous buffers, giving confidence in the quality of the sample used in any downstream experiments, whilst the use of fluorescence can assist in elucidating the origin subpopulations of EVs.

Whitepaper: NTA Exosomes and Microvesicles

Virus and Vaccines

Manufacture of vaccines requires controlled production processes to ensure that the materials can be appropriately dosed and recognised by the immune system. NTA assists in the optimization of manufacturing processes by ensuring the size distribution of the vaccine is maintained. As NTA is also able to count and size viruses, it can be used as a faster alternative to titre assays.

Drug Delivery & Gene Therapy

With drug delivery and gene therapy products, 70-150nm is the typical size of particles required to ensure effective disease targeting in the clinical. NTA is ideally suited to study the size of these particles from early stage research through to candidate screening, formulation development and clinical batch monitoring whilst the concentration measurement allows for dose determination of the final product as well as for use in in vitro and in vivo assays.

Whitepaper: NTA Applications in drug delivery

Biotherapeutics

Temperature, pH change, agitation, shear and time all impact the stability of biotherapeutic proteins, causing denaturation and aggregation which can cause loss of efficacy and the potential for an unwanted immune response. NTA provides high resolution size distributions of sub-visible aggregates in a formulation for safety and quality assurance.

Nanomaterials/colloids/toxicology

As nanomaterials are incorporated in to everyday items, they are coming to the attention of regulatory bodies. There is a requirement to fully characterize these particles, their properties and contribution in the final product. NanoSight can provide a number-based concentration for these nanomaterials and high-resolution size distributions for those working at the nanoscale in industrial, environmental and toxicological fields.

Ultrafine bubbles

In recent years work on ultrafine bubbles has been gathering momentum for use in industrial cleaning and water treatment, agriculture and food, medical applications amongst other. Their relatively low concentration and small size are a challenge for many traditional nanoparticle characterization techniques whereas NTA is particularly adept at the detection and analysis of these bubbles.

Academia

NTA is a key tool in the nanoparticle characterization tool kit for many academic laboratories worldwide, providing high resolution information on both monomodal and polydisperse systems across many different material types. The global adoption of NanoSight NTA is confirmed by thousands of academic publications.

General

Wavelength:
405nm (violet), 488nm (blue), 532nm (green) or 642nm (red).
Temperature control range:
5°C below ambient to 50°C.
Stage:
Fixed stage.
Focus:
Computer controlled motorized focus.
Camera:
sCMOS.
Fluorescence:
Motorized 6 place filter wheel with choice of filters.
Dimensions (W, D, H):
400mm x 250mm x 400mm.
Particle size:

10nm to 2000nm*

*Sample and system configuration dependent

Concentration range:
106 to 109 particles per mL.
Power:
100V - 240V

NanoSight NS300

NanoSight Sample Assistant

Image

Sample storage and automated delivery system

The NanoSight Sample Assistant is a 96-well plate-based autosampler accessory with a bespoke software suite for SOP generation via an intuitive user interface for automated NTA measurements.
More information

NanoSight syringe pump

Image

The Malvern Panalytical NanoSight syringe pump is available for all Malvern Panalytical NanoSight systems, enabling users to perform sample analysis at a constant flow rate.

More information

Protect your investment and ensure optimized performance at all times with Malvern Panalytical's service plans.

When you purchase a Malvern Panalytical product we understand that this is just the first stage of a working relationship that will last for the lifetime of the instrument. Depending on your needs, Malvern Panalytical will provide the support for your business.

Help Desk

Training

Software downloads

Malvern Panalytical's service options- choose the right plan for you:

Malvern Panalytical Platinum Plan

For laboratories where maximizing instrument up-time is critical to its daily performance. Our highest level of response and the 'all inclusive' price plan takes care of those unexpected repair bills should the unfortunate occur.

Malvern Panalytical Gold Plan

Enhance your laboratory productivity by maintaining instrument efficiency. Still receive that priority response, combined with specialist technical and software support, we'll keep your instrument performance on track to deliver.

Malvern Panalytical Bronze Visit

For laboratories looking to optimize instrument performance, regular preventative maintenance is essential.

Platinum PlanGold PlanBronze Visit
Annual PM/PV Test
yes
yes
no
Telephone / Email Support
yes
yes
no
Priority Response
yes
yes
no
Emergency Breakdown visits*
yes
yes
no
Parts Included
yes
no
no
Technical & Software Support
yes
yes
yes
IQ/OQ (Pharma)***
yes
yes
yes

*including labour & travel costs***available at an additional cost