Zetasizer Advance Range

Light Scattering for every application

Zetasizer Advance Range

Zetasizer Advance is the successor to the highly successful and market-leading Zetasizer Nano.

Each of the three models in the Zetasizer Advance Range offers particle size, particle charge (zeta potential) and molecular weight analysis. In addition, each benefits from advances including Adaptive Correlation, M3-PALS zeta potential analysis, constant current zeta mode and our deep learning-based data quality advice system.

Each of the three models is available as a Blue Label or Red Label variant:

  • Choose Blue Label for routine sample investigation such as metallic colloids, metal oxides and pigments
  • Choose Red Label for more challenging sample types, such as proteins, surfactant solutions and low solid content samples

Find your perfect Zetasizer

All Zetasizer Advance systems offer on-site upgradeability with minimal downtime. Should your needs change, your Zetasizer can adapt to new challenges.

Om_logo.png  Works with OmniTrust: Malvern Panalytical's compliance solution for the regulated environment

Zetasizer Ultra

Our most advanced system for the measurement of particle and molecular size, particle charge and concentration.

Features include

  • Classic 90° DLS
  • Static light scattering
  • Non-Invasive Back Scatter DLS
  • Multi-Angle Dynamic Light Scattering
Zetasizer Ultra

Zetasizer Pro

The Zetasizer Pro is your go-to instrument to measure a wide range of sample types and concentrations.

Features include

  • Classic 90° DLS
  • Static light scattering
  • Non-Invasive Back Scatter DLS
  • Multi-Angle Dynamic Light Scattering
Zetasizer Pro

Zetasizer Lab

The Zetasizer Lab is an entry-level system that employs classical 90° sizing with advanced features.

Features include

  • Classic 90° DLS
  • Static light scattering
  • Non-Invasive Back Scatter DLS
  • Multi-Angle Dynamic Light Scattering
Zetasizer Lab

How our products compare

  • Zetasizer Ultra

    The world’s most trusted light scattering system

    Zetasizer Ultra
    • Classic 90° DLS
    • Non-Invasive Back Scatter DLS (NIBS)
    • Multi-Angle Dynamic Light Scattering (MADLS)
    • Static light scattering

    Size range

    • 0.3 nm to 15 μm

    Minimum volume

    • 3 μL
    • Zeta potential
    • Molecular weight

    Particle concentration / titer

    • Red Label only

    21 CFR part 11 compliant software

    • Optional

    Zeta potential size range

    • 3.8 nm to 100 μm
  • Zetasizer Pro

    High performance, versatile and robust

    Zetasizer Pro
    • Classic 90° DLS
    • Non-Invasive Back Scatter DLS (NIBS)
    • Multi-Angle Dynamic Light Scattering (MADLS)
    • Static light scattering

    Size range

    • 0.3 nm to 10 μm

    Minimum volume

    • 12 μL
    • Zeta potential
    • Molecular weight

    Particle concentration / titer

    • Particle concentration / titer

    21 CFR part 11 compliant software

    • Optional

    Zeta potential size range

    • 3.8 nm to 100 μm
  • Zetasizer Lab

    Classic side scatter particle size and zeta potential analyzer with enhanced capabilities

    Zetasizer Lab
    • Classic 90° DLS
    • Non-Invasive Back Scatter DLS (NIBS)
    • Multi-Angle Dynamic Light Scattering (MADLS)
    • Static light scattering

    Size range

    • 0.3 nm to 15 μm

    Minimum volume

    • 3 μL
    • Zeta potential
    • Molecular weight

    Particle concentration / titer

    • Particle concentration / titer

    21 CFR part 11 compliant software

    • Optional

    Zeta potential size range

    • 3.8 nm to 100 μm