Access support to accelerate your scientific discovery with grants of up to $20K or $50K, or up to 50% off. Apply to our Academic Grant Program now

Apply to our Academic Grant Program now

Zetasizer Pro

High performance, versatile and robust

  • Measure a wide range of sample types and concentrations
  • Wide dynamic concentration capability and high sensitivity with NIBS optical design
  • Adaptive Correlation enhances sample throughput
  • Optical filter wheel allows measurement of fluorescent samples
  • ZS Xplorer software suite, for simple and flexible method set-up and data analysis  

Select a model:

Looking for more information?

To request a quote, more information or download a brochure select an option below.

Overview

The new Zetasizer Pro is your go-to instrument to measure a wide range of sample types and concentrations. It offers wide dynamic concentration capability and high sensitivity due to the Non-Invasive Back Scatter (NIBS) optical design. Measurement of particle sizemolecular size, electrophoretic mobility, zeta potential and molecular weight can all be performed with ease. 

The Adaptive Correlation feature enhances sample throughput by reducing measurement duration and providing greater sample knowledge. The deep learning-based data quality system gives you the confidence to know your data is the best it can be.  

The optical filter wheel allows measurement of fluorescent samples without impacting overall instrument sensitivity.

Available in Blue Label and Red Label variants:

  • Choose Blue Label for routine sample investigation such as metallic colloids, metal oxides and pigments
  • Choose Red Label for more challenging sample types, such as proteins, surfactant solutions and low solid content samples

Om_logo.png  Works with OmniTrust: Malvern Panalytical's compliance solution for the regulated environment

Features

  • Dynamic Light Scattering (DLS), which measures particle and molecule size, from 0.3 nm to 10 µm  

  • M3-PALS with Constant Current Mode, for zeta potential and electrophoretic mobility measurements  

  • Electrophoretic Light Scattering (ELS), which measures the zeta potential of particles and molecules, indicating sample stability and/or propensity to aggregate  

  • Non-Invasive Back Scatter (NIBS), optics for versatile, high sensitivity, particle and molecular size measurements and molecular weight measurements  

  • Adaptive Correlation, for faster, more reproducible sizing measurements with less sample preparation  

  • Deep learning-based data quality system, for assessment of any size data quality issues, with clear advice on how to improve results  

  • Optical filter wheel with fluorescence filter, to allow measurement of fluorescent samples without impairing overall system sensitivity.  Also includes polarization filters for DDLS measurements  

  • A range of disposable and reusable cells are available to optimize the measurement in terms of sample volume and concentration

  • On-site upgradeability to Zetasizer Ultra, should your requirements change  

  • The optional MPT-3 Autotitrator enables study of the effect of changes in pH  

Which Zetasizer is right for me?

Zetasizer Ultra Zetasizer Pro Zetasizer Lab
Size Measurement Principle Non-Invasive Back Scatter (NIBS)
Dynamic Light Scattering
Dynamic Light Scattering (90° and 13°)
Multi-Angle Dynamic Light Scattering (MADLS®)
Non-Invasive Back Scatter (NIBS)
Dynamic Light Scattering
Classical 90° Dynamic Light Scattering
Zeta Measurement Principle ELS with M3-PALS and Constant Current Zeta Mode ELS with M3-PALS and Constant Current Zeta Mode ELS with M3-PALS and Constant Current Zeta Mode
Molecular Weight and B22 Static Light Scattering (90° and 173°) Static Light Scattering (173°) Static Light Scattering (90°)
Optical Filter Wheel (Fluorescence/DDLS) Yes Yes No
Low Volume Disposable Sizing Cell with Extended Size Analysis Support Yes No Yes
MADLS® (High Resolution DLS) Yes No No
MADLS® - Particle Concentration/Titer Yes2 No No
21 CFR Part 11 compliant software Optional via Omnitrust Optional via Omnitrust Optional via Omnitrust
Size
Range2 0.3 nm to 10 μm 0.3 nm to 10 μm 0.3 nm to 10 μm
Minimum Volume 3 μL 12 μL 3 μL
Zeta potential
Size Range 3.8 nm to 100 μm 3.8 nm to 100 μm 3.8 nm to 100 μm
Minimum Volume3 20 μL 20 μL 20 μL

1  Red Label only
2  10 um by default. Option to extend for Zetasizer Lab and Zetasizer Ultra coming soon
3  Patented Diffusion Barrier method in capillary cell

Industry applications

The Zetasizer Advance Range is used in many industries, including:

Academia

The Zetasizer Lab is an essential analytical tool for many academic laboratories worldwide, finding use in all applications where particle or molecular size and zeta potential analysis is required. The breadth of applications covered by Zetasizer systems, coupled with tens of thousands of scientific citations, have earned these instruments a central space in many scientific faculties.

Bioscience

Variations in molecule concentration, external temperature, level of agitation and time all impact the stability of biological molecules.  Instabilities mainly result in denaturation and aggregation of the molecule through which they can lose their biological function , elicit an immune response and consequently limit its therapeutic viability. Factors affecting therapeutic efficacy and immunogenicity therefore need to be monitored throughout the development pipeline especially at early stages to de-risk the biological drug molecule and limit late-stage failures. The Zetasizer range provides high quality, stability indicating data for biological drug molecules in a short time frame, enabling this measurement to be implemented throughout the development pipeline.

Food and drink

Zetasizer systems are used to analyze particle size and zeta potential to improve the appearance and taste of foods, drinks and flavorings, and optimize dispersion and emulsion stability to extend product shelf life and improve product performance.

Nanomaterials

Zetasizer measurements of nanoparticle size distribution, dispersion properties, stability and propensity to aggregate are crucial to the design of new nanomaterials. The very large surface area of such materials may result in novel physical and chemical properties, such as increased catalytic activity, improved solubility or unexpected optical or toxicological behavior.

Paints, inks and coatings

Paint, ink and coating formulations must be stable to keep them in an optimum state over time without change or aggregation. Particle size and zeta potential, measured by the Zetasizer instruments, play important roles in determining a product’s properties, such as dispersibility, color, strength, finish, durability and shelf life.

Pharmaceuticals

The correct particle size and zeta potential can help ensure the production of effective therapeutics, delivered safely. Zetasizer systems are used to characterize the stability and quality of dispersions, emulsions and creams, reducing formulation time and speeding new products to market.

Key applications

The Zetasizer Advance Range is suitable for a wide range of applications, including:

Colloidal Silica

Sizing of colloidal silica is a critical requirement. This is easily and reproducibly measured using the Zetasizer Lab Blue Label.

Titanium Dioxide

Titanium dioxide use is wide-ranging. When used in paints or inks, agglomerate or aggregate formation can diminish product performance. The Zetasizer Pro Blue Label, used alongside the MPT‑3 Autotitrator, characterizes the impact of salt concentration on the stability of TiO2 and identifies the most stable pH region.

Ceramics

The strength of ceramics is linked to particle size, and the Zetasizer Ultra Blue Label is ideally placed to measure this. Al2O3 samples are often made of differently-sized particles which can easily be identified using MADLS. In this 0.1% w/v sample, the two particle size populations would not be distinguishable with a single angle DLS measurement.

Proteins

For protein researchers, early access to characterization data can be a challenge, due to low sample volumes. This is easily overcome using the Zetasizer Lab Red Label with the capillary cell to confirm that samples meet quality requirements and that production and purification processes are optimized.

Carbon Dots (C-dots)

Photoluminescent C-dots are considered safer alternatives to quantum dots. Measuring fluorescent samples by DLS can be challenging due to additional photons emitted by the fluorophore. Available with NIBS on Zetasizer Pro Red Label, a filter removes this interference to provide accurate and reliable data.

Adeno-Associated Virus (AAV)

Monitoring viral concentration is important during development and production optimization. By using the Multi-Angle DLS (MADLS) based particle concentration measurement in the Zetasizer Ultra Red Label, both the size distribution and titer of the virus can be measured within a few minutes.

The Zetasizer is one of the most user-friendly pieces of equipment I've used so far in my career. The instrument itself is easy to set up and operate. It has demonstrated high sensitivity for size measurements, and the datasets I've collected are consistent and reproducible."

Victoria Makal — University of Florida College of Medicine

Specification

Measurement principle
Non-Invasive Back Scatter (NIBS) 
Dynamic Light Scattering
Measurement angle 173°, 13°
Measurement range 0.3 nm - 10 μm
Minimum sample volume 12 μL
Concentration range
Minimum sample concentration: 
Blue Label: 0.2 mg/mL 15 kDa Protein
Red Label: 0.1 mg/mL 15 kDa Protein
 
Maximum sample concentration: (3)
40% w/v 

Accessories

Smart Manager

Unleash the potential of your data

Until now, instrument data has too often been stuck in manual records, spreadsheets or site-specific servers. By connecting your Zetasizer to our Smart Manager and continually analyzing instrument data in the cloud, you can unleash its full potential. This is just one of our digital solutions that are part of Malvern Panalytical's Smart Manager.

Smart Install

Get your new Zetasizer up and running faster when you choose to smart install. 

With comprehensive resources to help you quickly and safely set-up and verify the performance of your new instrument, there’s no need to wait for an engineer to do it for you. What’s more, smart install presents a new training opportunity as you receive full access to exclusive training material. 

How does it work?

When you follow the step-by-step video instructions, you could be up and running within 90 minutes of delivery of your new Zetasizer. 

You don't need any specific skills or knowledge to perform a smart installation. Simply follow the instructions provided. 

Everything needed to get started is provided with your new instrument – all you need is an internet connection to access the online training. 

Exclusive e-learning content

Resources to get you up and running quickly and with confidence include:  

  • detailed video guides walk you through installation and set-up;
  • 15-months  access to the Essentials e-learning course, which is provided at no extra cost;
  • a comprehensive user manual.

Find out more about smart install.

User manuals

Software downloads

20 October 2025

4.2.0

ZS Xplorer 4.2.0 extends coverage of OmniTrust, our regulated environment solution, to cover Sample Assistant functionality.

Adds persistence for Sample Assistant sessions and upgrades License Manager to 2.0.

Please read the SUN for full details. 

4.2.0

04 June 2025

4.1.0

ZS Xplorer 4.1.0 release further extends Zetasizer Sample Assistant integration with additional features and quality of life improvements. 

ZS Xplorer 4.1.0 introduces support for sample storage thermoblocks.  


General improvements to Sample Assistant robustness and ability to pause running sessions added. 

4.1.0

24 September 2024

4.0.0

ZS Xplorer 4.0.0 is the first version to support the new Zetasizer Sample Assistant automated particle size and Zeta potential sample changer.  Small updates to Smart Manager components are also included.


Please Note: OmniTrust (regulated environment) users will not be able to access Sample Assistant as the feature does not currently support OmniTrust. 


See SUN for full details.

 

4.0.0

08 December 2023

3.31

Maintenance release, updates to key services and addition of Titration summary data logs.


See SUN for full details.

 

3.31

02 August 2023

3.30

ZS Xplorer version 3.3 extends OmniTrust support to the Studies features of the main application. Previously OmniTrust users were prevented from accessing Studies to prevent un-audited events. From 3.3 OmniTrust users can now access Studies for Molecular Weight and associated parameters with permissions and auditing of events within the Studies features.  


Note that Studies by their nature are intended for advanced users and to be flexible in their analysis. Users not requiring Studies features can still prevent access to these features using permissions in OmniAccess.


Version 3.3 also addresses a few minor bug fixes.


See SUN for full details.

 

3.30

02 May 2023

3.22

ZS Xplorer 3.2.2 has the following updates: 

 

Software re-branded to Malvern Panalytical brand

Minor bug fixes - one of which may have prevented instrument connection

Bug fix for OmniTrust users that meant editing of records was possible, even when user permission for this action was disabled (recommended update for OmniTrust users currently on ZS Xplorer 3.2.1.)

Updated Toluene calibration routine to prevent incorrect reporting of issues with calibration.


See SUN for full details.

3.22

19 December 2022

3.21

ZS Xplorer 3.2.1 adds Smart Instrument enrollment - the first step in bringing Zetasizer into Malvern Panalytical's Smart Manager services.

Several installer improvements have been made to reduce ZS Xplorer requirements around .NET and WebView2 components.

We have also added ability to edit peak thresholds for size measurements and refinements on CSV exporting from parameter tables.


See SUN for full details.

3.21

04 October 2022

3.20

ZS Xplorer version 3.2.0 adds upper and lower display range configuration for Size/MADLS & Particle Concentration measurements.

Introduces Data Quality Advice for MADLS & Particle Concentration measurements.  

Adds further Trend analysis improvements and bug fixes.

Extends Japanese and Chinese localization to Studies and Data Quality Advice.

Adds speed and robustness improvements to Scattering standard measurements.

Other improvements and bug fixes.  

See SUN for full details.

3.20

11 July 2022

3.10

ZS Xplorer version 3.1.0 extends studies and concentration trend measurements to support the Zetasizer Advance Lab models and also adds the capability to perform concentration trends in either back or side scatter on Zetasizer Advance Ultra models.   Concentration trends also now supports setting of measurement temperature and adds display of R2 value to tables and graphs.

Exporting of data to CSV file from graphs and tables in Concentration trends and from Parameter and Statistic tables in Analyze views has been introduced.

Data quality advice for Zeta potential measurements has been further refined to provide users with better diagnosis of sample/measurement issues. 

Exporting a study now provides an option to include the results data for transfer of the complete study between data repositories.

Various bug fixes, see software update notification for details.

3.10

18 May 2022

3.00

ZS Xplorer version 3.0.0 introduces studies and concentration trend measurements for the determination of molecular weight by static light scattering and kD by dynamic light scattering. Note: This first release does not support Zetasizer Lab or OmniTrust users. Auto averaging for Zeta, MADLS and Particle concentration has also been added along with other quality of life features and bug fixes. See SUN for details.

3.00

01 March 2022

2.31

ZS Xplorer version 2.3.1 introduces post-analysis averaging for Zeta, Particle Concentration and MADLS size measurements. Zeta mobility parameters and graphs have

 

been added, as well as a count rate meter and

 

localization for Chinese (Simplified) and Japanese language support.

Important: This version supports OmniTrust 1.4.0; OmniTrust users should upgrade their installation to 1.4 if upgrading to ZS Xplorer 2.3.1.

2.31

17 January 2022

2.30

ZS Xplorer version 2.3.0 introduces post analysis averaging for Zeta, Particle Concentration and MADLS size measurements. Zeta mobility parameters and graphs have also been added, as well as a count rate meter.


Important: This version supports OmniTrust 1.4.0; OmniTrust users should upgrade their installation to 1.4 if upgrading to ZS Xplorer 2.3.0.

details.

2.30

14 October 2021

2.20

  • Maintenance release see Software Update Notification for details.
2.20

08 July 2021

2.10

  • ZS Xplorer 2.1 offers improvements to OmniTrust regulated environment users by providing improved control of methods and provision of a method audit trail. This version also provides improvements by provision of major size distribution percentiles and automatic size averaging function. A critical bug that could  affect zeta potential data for very low scattering samples has also been fixed. See the Software Update Notification for more details.

2.10

25 February 2021

2.01

  • Bug fix: Changing sample details on locked methods
    • Fixed a bug around method permissions for OmniTrust regulated environment users that prevented editing of method sample details.
2.01

23 June 2025

1.7a

OmniTrust software update v1.7a

1.7a

20 July 2023

1.60

OmniAccess   

  • Flexible/configurable roles in Empyrean and Aeris (now aligns with Zetasizer) 
  • Summary of roles/permissions 
  • Default roles for instrument applications 
  • Support for complex domains 
  • Wizard for initial set up and massively improved UI to improve configuration/set up 

OmniTrail  

  • Record Audit trail events viewable in OmniTrail. 
  • Show/compare authorization files 

More information can be found in the Release and Installation Notes.

1.60

16 December 2021

1.40

OmniAccess   

  • Flexible/configurable roles in Empyrean and Aeris (now aligns with Zetasizer) 
  • Summary of roles/permissions 
  • Default roles for instrument applications 
  • Support for complex domains 
  • Wizard for initial set up and massively improved UI to improve configuration/set up 

OmniTrail  

  • Record Audit trail events viewable in OmniTrail. 
  • Show/compare authorization files 

More information can be found in the Release and Installation Notes.

1.40

Unleash the full potential of your Malvern Panalytical solution

[Technical support services cut corner engineer icon.jpg] Technical support services cut corner engineer icon.jpg

Unmatched uptime and performance


Malvern Panalytical instruments are built to last and good maintenance and care ensure continued peak performance for many years to come.

  • Service Agreements  build this into your schedule and budget, based on  preventive maintenance and remote support . Different levels include repair visits, response times and parts coverage as needed. OQ services, training and application consultancy can be added as well.

[PN13012_2520_CLV_Photography_MP_JN.jpg] PN13012_2520_CLV_Photography_MP_JN.jpg
Service Agreements
Find out more about our service agreement options tailored for you
Learn more >>

[Training and expertise cut corner presenter icon.jpg] Training and expertise cut corner presenter icon.jpg

Advanced analysis and actionable insights


  • Basic User Training : Master the art of optimal Zetasizer usage and determine whether your measurements, sample preparation, and data are accurate and reliable – all while uncovering invaluable maintenance tips and tricks.  Find your online or offline classroom training course .
  • Customized Application Training : A training journey personalized to your application needs , covering aspects from sample taking and method development to data and results interpretation. Our application scientists share in-depth theory and best practices to make sure you’re getting the most out of your Zetasizer measurements and instruments.
  • Analytical and Consultancy Services : Our expert services place specialists and scientists at your disposal for method development, sample preparation, and certification. From oxides to sulfides, from trace to major elements, from particle sizing to molecular interaction – gain unparalleled analytical expertise.  Find out more .
[Product support cut corner cog icon.jpg] Product support cut corner cog icon.jpg

Easy start and streamlined routine operations


  • Setting up for success: Our Zetasizer onboarding starts with our expert support engineers on-site, or if you’d like to set up the instrument yourself, our self-install will guide you. Either way, a comprehensive warranty and a starter training program are complimentary, so you can get straight to your important analyses.
  • Software and Manuals:  Easily find  manuals and our latest software versions  online to benefit from new features and to stay up to date.
  • Webinars and App Notes:  Access a  comprehensive catalog of resources , such as recorded webinars, white papers, and app notes to support your analytical journey. 
  • Parts and Consumables -   MyStoreOur online store  makes access to your parts, consumables, accessories, and software convenient and efficient. Check availability and pricing, self-service quotes and order on card or account, 24/7. 
  • Support Portal:  Our professional service team is ready to assist you – fast-track your service request on  Malvern Panalytical My Customer Support Portal  or view your system details and service history at a glance.
[Service team and contact cut corner agent icon.jpg] Service team and contact cut corner agent icon.jpg

Want to speak to a service expert or find the services that are just right for you?


Reach out to our experts and evaluate your services needs and business risks by answering a few questions around the usage of your Malvern Panalytical instrument.


Contact Service Team

*Please note that the exact details of our services and their availability are determined by a variety of customer-specific factors, such as product type, product configuration, or location.

Publications

Overview

The new Zetasizer Pro is your go-to instrument to measure a wide range of sample types and concentrations. It offers wide dynamic concentration capability and high sensitivity due to the Non-Invasive Back Scatter (NIBS) optical design. Measurement of particle sizemolecular size, electrophoretic mobility, zeta potential and molecular weight can all be performed with ease. 

The Adaptive Correlation feature enhances sample throughput by reducing measurement duration and providing greater sample knowledge. The deep learning-based data quality system gives you the confidence to know your data is the best it can be.  

The optical filter wheel allows measurement of fluorescent samples without impacting overall instrument sensitivity.

Available in Blue Label and Red Label variants:

  • Choose Blue Label for routine sample investigation such as metallic colloids, metal oxides and pigments
  • Choose Red Label for more challenging sample types, such as proteins, surfactant solutions and low solid content samples

Om_logo.png  Works with OmniTrust: Malvern Panalytical's compliance solution for the regulated environment

Features

  • Dynamic Light Scattering (DLS), which measures particle and molecule size, from 0.3 nm to 10 µm  

  • M3-PALS with Constant Current Mode, for zeta potential and electrophoretic mobility measurements  

  • Electrophoretic Light Scattering (ELS), which measures the zeta potential of particles and molecules, indicating sample stability and/or propensity to aggregate  

  • Non-Invasive Back Scatter (NIBS), optics for versatile, high sensitivity, particle and molecular size measurements and molecular weight measurements  

  • Adaptive Correlation, for faster, more reproducible sizing measurements with less sample preparation  

  • Deep learning-based data quality system, for assessment of any size data quality issues, with clear advice on how to improve results  

  • Optical filter wheel with fluorescence filter, to allow measurement of fluorescent samples without impairing overall system sensitivity.  Also includes polarization filters for DDLS measurements  

  • A range of disposable and reusable cells are available to optimize the measurement in terms of sample volume and concentration

  • On-site upgradeability to Zetasizer Ultra, should your requirements change  

  • The optional MPT-3 Autotitrator enables study of the effect of changes in pH  

Which Zetasizer is right for me?

Zetasizer Ultra Zetasizer Pro Zetasizer Lab
Size Measurement Principle Non-Invasive Back Scatter (NIBS)
Dynamic Light Scattering
Dynamic Light Scattering (90° and 13°)
Multi-Angle Dynamic Light Scattering (MADLS®)
Non-Invasive Back Scatter (NIBS)
Dynamic Light Scattering
Classical 90° Dynamic Light Scattering
Zeta Measurement Principle ELS with M3-PALS and Constant Current Zeta Mode ELS with M3-PALS and Constant Current Zeta Mode ELS with M3-PALS and Constant Current Zeta Mode
Molecular Weight and B22 Static Light Scattering (90° and 173°) Static Light Scattering (173°) Static Light Scattering (90°)
Optical Filter Wheel (Fluorescence/DDLS) Yes Yes No
Low Volume Disposable Sizing Cell with Extended Size Analysis Support Yes No Yes
MADLS® (High Resolution DLS) Yes No No
MADLS® - Particle Concentration/Titer Yes2 No No
21 CFR Part 11 compliant software Optional via Omnitrust Optional via Omnitrust Optional via Omnitrust
Size
Range2 0.3 nm to 10 μm 0.3 nm to 10 μm 0.3 nm to 10 μm
Minimum Volume 3 μL 12 μL 3 μL
Zeta potential
Size Range 3.8 nm to 100 μm 3.8 nm to 100 μm 3.8 nm to 100 μm
Minimum Volume3 20 μL 20 μL 20 μL

1  Red Label only
2  10 um by default. Option to extend for Zetasizer Lab and Zetasizer Ultra coming soon
3  Patented Diffusion Barrier method in capillary cell

Industry applications

The Zetasizer Advance Range is used in many industries, including:

Academia

The Zetasizer Lab is an essential analytical tool for many academic laboratories worldwide, finding use in all applications where particle or molecular size and zeta potential analysis is required. The breadth of applications covered by Zetasizer systems, coupled with tens of thousands of scientific citations, have earned these instruments a central space in many scientific faculties.

Bioscience

Variations in molecule concentration, external temperature, level of agitation and time all impact the stability of biological molecules.  Instabilities mainly result in denaturation and aggregation of the molecule through which they can lose their biological function , elicit an immune response and consequently limit its therapeutic viability. Factors affecting therapeutic efficacy and immunogenicity therefore need to be monitored throughout the development pipeline especially at early stages to de-risk the biological drug molecule and limit late-stage failures. The Zetasizer range provides high quality, stability indicating data for biological drug molecules in a short time frame, enabling this measurement to be implemented throughout the development pipeline.

Food and drink

Zetasizer systems are used to analyze particle size and zeta potential to improve the appearance and taste of foods, drinks and flavorings, and optimize dispersion and emulsion stability to extend product shelf life and improve product performance.

Nanomaterials

Zetasizer measurements of nanoparticle size distribution, dispersion properties, stability and propensity to aggregate are crucial to the design of new nanomaterials. The very large surface area of such materials may result in novel physical and chemical properties, such as increased catalytic activity, improved solubility or unexpected optical or toxicological behavior.

Paints, inks and coatings

Paint, ink and coating formulations must be stable to keep them in an optimum state over time without change or aggregation. Particle size and zeta potential, measured by the Zetasizer instruments, play important roles in determining a product’s properties, such as dispersibility, color, strength, finish, durability and shelf life.

Pharmaceuticals

The correct particle size and zeta potential can help ensure the production of effective therapeutics, delivered safely. Zetasizer systems are used to characterize the stability and quality of dispersions, emulsions and creams, reducing formulation time and speeding new products to market.

Key applications

The Zetasizer Advance Range is suitable for a wide range of applications, including:

Colloidal Silica

Sizing of colloidal silica is a critical requirement. This is easily and reproducibly measured using the Zetasizer Lab Blue Label.

Titanium Dioxide

Titanium dioxide use is wide-ranging. When used in paints or inks, agglomerate or aggregate formation can diminish product performance. The Zetasizer Pro Blue Label, used alongside the MPT‑3 Autotitrator, characterizes the impact of salt concentration on the stability of TiO2 and identifies the most stable pH region.

Ceramics

The strength of ceramics is linked to particle size, and the Zetasizer Ultra Blue Label is ideally placed to measure this. Al2O3 samples are often made of differently-sized particles which can easily be identified using MADLS. In this 0.1% w/v sample, the two particle size populations would not be distinguishable with a single angle DLS measurement.

Proteins

For protein researchers, early access to characterization data can be a challenge, due to low sample volumes. This is easily overcome using the Zetasizer Lab Red Label with the capillary cell to confirm that samples meet quality requirements and that production and purification processes are optimized.

Carbon Dots (C-dots)

Photoluminescent C-dots are considered safer alternatives to quantum dots. Measuring fluorescent samples by DLS can be challenging due to additional photons emitted by the fluorophore. Available with NIBS on Zetasizer Pro Red Label, a filter removes this interference to provide accurate and reliable data.

Adeno-Associated Virus (AAV)

Monitoring viral concentration is important during development and production optimization. By using the Multi-Angle DLS (MADLS) based particle concentration measurement in the Zetasizer Ultra Red Label, both the size distribution and titer of the virus can be measured within a few minutes.

The Zetasizer is one of the most user-friendly pieces of equipment I've used so far in my career. The instrument itself is easy to set up and operate. It has demonstrated high sensitivity for size measurements, and the datasets I've collected are consistent and reproducible."

Victoria Makal — University of Florida College of Medicine

Specification

Measurement principle
Non-Invasive Back Scatter (NIBS) 
Dynamic Light Scattering
Measurement angle 173°, 13°
Measurement range 0.3 nm - 10 μm
Minimum sample volume 12 μL
Concentration range
Minimum sample concentration: 
Blue Label: 0.2 mg/mL 15 kDa Protein
Red Label: 0.1 mg/mL 15 kDa Protein
 
Maximum sample concentration: (3)
40% w/v 

Accessories

Smart Manager

Unleash the potential of your data

Until now, instrument data has too often been stuck in manual records, spreadsheets or site-specific servers. By connecting your Zetasizer to our Smart Manager and continually analyzing instrument data in the cloud, you can unleash its full potential. This is just one of our digital solutions that are part of Malvern Panalytical's Smart Manager.

Smart Install

Get your new Zetasizer up and running faster when you choose to smart install. 

With comprehensive resources to help you quickly and safely set-up and verify the performance of your new instrument, there’s no need to wait for an engineer to do it for you. What’s more, smart install presents a new training opportunity as you receive full access to exclusive training material. 

How does it work?

When you follow the step-by-step video instructions, you could be up and running within 90 minutes of delivery of your new Zetasizer. 

You don't need any specific skills or knowledge to perform a smart installation. Simply follow the instructions provided. 

Everything needed to get started is provided with your new instrument – all you need is an internet connection to access the online training. 

Exclusive e-learning content

Resources to get you up and running quickly and with confidence include:  

  • detailed video guides walk you through installation and set-up;
  • 15-months  access to the Essentials e-learning course, which is provided at no extra cost;
  • a comprehensive user manual.

Find out more about smart install.

User manuals

Software downloads

20 October 2025

4.2.0

ZS Xplorer 4.2.0 extends coverage of OmniTrust, our regulated environment solution, to cover Sample Assistant functionality.

Adds persistence for Sample Assistant sessions and upgrades License Manager to 2.0.

Please read the SUN for full details. 

4.2.0

04 June 2025

4.1.0

ZS Xplorer 4.1.0 release further extends Zetasizer Sample Assistant integration with additional features and quality of life improvements. 

ZS Xplorer 4.1.0 introduces support for sample storage thermoblocks.  


General improvements to Sample Assistant robustness and ability to pause running sessions added. 

4.1.0

24 September 2024

4.0.0

ZS Xplorer 4.0.0 is the first version to support the new Zetasizer Sample Assistant automated particle size and Zeta potential sample changer.  Small updates to Smart Manager components are also included.


Please Note: OmniTrust (regulated environment) users will not be able to access Sample Assistant as the feature does not currently support OmniTrust. 


See SUN for full details.

 

4.0.0

08 December 2023

3.31

Maintenance release, updates to key services and addition of Titration summary data logs.


See SUN for full details.

 

3.31

02 August 2023

3.30

ZS Xplorer version 3.3 extends OmniTrust support to the Studies features of the main application. Previously OmniTrust users were prevented from accessing Studies to prevent un-audited events. From 3.3 OmniTrust users can now access Studies for Molecular Weight and associated parameters with permissions and auditing of events within the Studies features.  


Note that Studies by their nature are intended for advanced users and to be flexible in their analysis. Users not requiring Studies features can still prevent access to these features using permissions in OmniAccess.


Version 3.3 also addresses a few minor bug fixes.


See SUN for full details.

 

3.30

02 May 2023

3.22

ZS Xplorer 3.2.2 has the following updates: 

 

Software re-branded to Malvern Panalytical brand

Minor bug fixes - one of which may have prevented instrument connection

Bug fix for OmniTrust users that meant editing of records was possible, even when user permission for this action was disabled (recommended update for OmniTrust users currently on ZS Xplorer 3.2.1.)

Updated Toluene calibration routine to prevent incorrect reporting of issues with calibration.


See SUN for full details.

3.22

19 December 2022

3.21

ZS Xplorer 3.2.1 adds Smart Instrument enrollment - the first step in bringing Zetasizer into Malvern Panalytical's Smart Manager services.

Several installer improvements have been made to reduce ZS Xplorer requirements around .NET and WebView2 components.

We have also added ability to edit peak thresholds for size measurements and refinements on CSV exporting from parameter tables.


See SUN for full details.

3.21

04 October 2022

3.20

ZS Xplorer version 3.2.0 adds upper and lower display range configuration for Size/MADLS & Particle Concentration measurements.

Introduces Data Quality Advice for MADLS & Particle Concentration measurements.  

Adds further Trend analysis improvements and bug fixes.

Extends Japanese and Chinese localization to Studies and Data Quality Advice.

Adds speed and robustness improvements to Scattering standard measurements.

Other improvements and bug fixes.  

See SUN for full details.

3.20

11 July 2022

3.10

ZS Xplorer version 3.1.0 extends studies and concentration trend measurements to support the Zetasizer Advance Lab models and also adds the capability to perform concentration trends in either back or side scatter on Zetasizer Advance Ultra models.   Concentration trends also now supports setting of measurement temperature and adds display of R2 value to tables and graphs.

Exporting of data to CSV file from graphs and tables in Concentration trends and from Parameter and Statistic tables in Analyze views has been introduced.

Data quality advice for Zeta potential measurements has been further refined to provide users with better diagnosis of sample/measurement issues. 

Exporting a study now provides an option to include the results data for transfer of the complete study between data repositories.

Various bug fixes, see software update notification for details.

3.10

18 May 2022

3.00

ZS Xplorer version 3.0.0 introduces studies and concentration trend measurements for the determination of molecular weight by static light scattering and kD by dynamic light scattering. Note: This first release does not support Zetasizer Lab or OmniTrust users. Auto averaging for Zeta, MADLS and Particle concentration has also been added along with other quality of life features and bug fixes. See SUN for details.

3.00

01 March 2022

2.31

ZS Xplorer version 2.3.1 introduces post-analysis averaging for Zeta, Particle Concentration and MADLS size measurements. Zeta mobility parameters and graphs have

 

been added, as well as a count rate meter and

 

localization for Chinese (Simplified) and Japanese language support.

Important: This version supports OmniTrust 1.4.0; OmniTrust users should upgrade their installation to 1.4 if upgrading to ZS Xplorer 2.3.1.

2.31

17 January 2022

2.30

ZS Xplorer version 2.3.0 introduces post analysis averaging for Zeta, Particle Concentration and MADLS size measurements. Zeta mobility parameters and graphs have also been added, as well as a count rate meter.


Important: This version supports OmniTrust 1.4.0; OmniTrust users should upgrade their installation to 1.4 if upgrading to ZS Xplorer 2.3.0.

details.

2.30

14 October 2021

2.20

  • Maintenance release see Software Update Notification for details.
2.20

08 July 2021

2.10

  • ZS Xplorer 2.1 offers improvements to OmniTrust regulated environment users by providing improved control of methods and provision of a method audit trail. This version also provides improvements by provision of major size distribution percentiles and automatic size averaging function. A critical bug that could  affect zeta potential data for very low scattering samples has also been fixed. See the Software Update Notification for more details.

2.10

25 February 2021

2.01

  • Bug fix: Changing sample details on locked methods
    • Fixed a bug around method permissions for OmniTrust regulated environment users that prevented editing of method sample details.
2.01

23 June 2025

1.7a

OmniTrust software update v1.7a

1.7a

20 July 2023

1.60

OmniAccess   

  • Flexible/configurable roles in Empyrean and Aeris (now aligns with Zetasizer) 
  • Summary of roles/permissions 
  • Default roles for instrument applications 
  • Support for complex domains 
  • Wizard for initial set up and massively improved UI to improve configuration/set up 

OmniTrail  

  • Record Audit trail events viewable in OmniTrail. 
  • Show/compare authorization files 

More information can be found in the Release and Installation Notes.

1.60

16 December 2021

1.40

OmniAccess   

  • Flexible/configurable roles in Empyrean and Aeris (now aligns with Zetasizer) 
  • Summary of roles/permissions 
  • Default roles for instrument applications 
  • Support for complex domains 
  • Wizard for initial set up and massively improved UI to improve configuration/set up 

OmniTrail  

  • Record Audit trail events viewable in OmniTrail. 
  • Show/compare authorization files 

More information can be found in the Release and Installation Notes.

1.40

Unleash the full potential of your Malvern Panalytical solution

[Technical support services cut corner engineer icon.jpg] Technical support services cut corner engineer icon.jpg

Unmatched uptime and performance


Malvern Panalytical instruments are built to last and good maintenance and care ensure continued peak performance for many years to come.

  • Service Agreements  build this into your schedule and budget, based on  preventive maintenance and remote support . Different levels include repair visits, response times and parts coverage as needed. OQ services, training and application consultancy can be added as well.

[PN13012_2520_CLV_Photography_MP_JN.jpg] PN13012_2520_CLV_Photography_MP_JN.jpg
Service Agreements
Find out more about our service agreement options tailored for you
Learn more >>

[Training and expertise cut corner presenter icon.jpg] Training and expertise cut corner presenter icon.jpg

Advanced analysis and actionable insights


  • Basic User Training : Master the art of optimal Zetasizer usage and determine whether your measurements, sample preparation, and data are accurate and reliable – all while uncovering invaluable maintenance tips and tricks.  Find your online or offline classroom training course .
  • Customized Application Training : A training journey personalized to your application needs , covering aspects from sample taking and method development to data and results interpretation. Our application scientists share in-depth theory and best practices to make sure you’re getting the most out of your Zetasizer measurements and instruments.
  • Analytical and Consultancy Services : Our expert services place specialists and scientists at your disposal for method development, sample preparation, and certification. From oxides to sulfides, from trace to major elements, from particle sizing to molecular interaction – gain unparalleled analytical expertise.  Find out more .
[Product support cut corner cog icon.jpg] Product support cut corner cog icon.jpg

Easy start and streamlined routine operations


  • Setting up for success: Our Zetasizer onboarding starts with our expert support engineers on-site, or if you’d like to set up the instrument yourself, our self-install will guide you. Either way, a comprehensive warranty and a starter training program are complimentary, so you can get straight to your important analyses.
  • Software and Manuals:  Easily find  manuals and our latest software versions  online to benefit from new features and to stay up to date.
  • Webinars and App Notes:  Access a  comprehensive catalog of resources , such as recorded webinars, white papers, and app notes to support your analytical journey. 
  • Parts and Consumables -   MyStoreOur online store  makes access to your parts, consumables, accessories, and software convenient and efficient. Check availability and pricing, self-service quotes and order on card or account, 24/7. 
  • Support Portal:  Our professional service team is ready to assist you – fast-track your service request on  Malvern Panalytical My Customer Support Portal  or view your system details and service history at a glance.
[Service team and contact cut corner agent icon.jpg] Service team and contact cut corner agent icon.jpg

Want to speak to a service expert or find the services that are just right for you?


Reach out to our experts and evaluate your services needs and business risks by answering a few questions around the usage of your Malvern Panalytical instrument.


Contact Service Team

*Please note that the exact details of our services and their availability are determined by a variety of customer-specific factors, such as product type, product configuration, or location.

Advanced light scattering with NIBS for exceptional size measurement.

Advanced light scattering with NIBS for exceptional size measurement.

Particle and molecular analysis in an easy to use, compact instrument. Advance your data capabilities with the world-leading successor to the Nano range.

Request a quote Request a demo