Ask MyScientist. Get answers instantly. Access trusted application expertise powered by decades of Malvern Panalytical knowledge. Solve challenges faster, make confident decisions, and keep your work moving forward. Ask a Question

Ask a Question

Zetasizer Lab

Classic side scatter particle size and zeta potential analyzer with enhanced capabilities

  • Traditional 90-degree side-scatter size measurements 
  • Adaptive Correlation, M3-PALS, and constant current zeta mode 
  • Extended size range analysis when used with ZSU1002 capillary cell
  • ZS Xplorer analytical software offers instant feedback on data quality, and guidance on how to improve your results

Select a model:

Looking for more information?

To request a quote, more information or download a brochure select an option below.

Entry-level DLS with advanced functionality.

Adaptive Correlation, M3-PALS and constant current zeta mode, with easy to use software and data quality feedback. 

All incorporated into a compact, user-friendly instrument.

Features

  • DLS analysis : particle size measurements from 0.3 nm to 10 μm

  • Zeta potential of nanoparticles and colloids using M3-PALS analysis and constant current zeta mode

  • Molecular weight using Static Light Scattering at 90°

  • Supports use of Low Volume Disposable Capillary Cell for size measurements in sample volumes as low as 3 μL

  • Extended size range analysis offers improved accuracy for particle sizes above 1 μm, and indicative results above 10 μm (using ZSU1002 Low Volume Disposable Sizing Cell)

  • On-site upgradeability to either Zetasizer Pro or Zetasizer Ultra models

Trust every result, every time.

Reliability

Insight to impact, faster and hands-free

Efficiency

One platform, endless applications.

Application

Industry applications

  • The Zetasizer is an essential analytical tool for many academic laboratories worldwide, finding use in all applications where particle or molecular size and zeta potential analysis is required. The breadth of applications covered by Zetasizer systems, coupled with tens of thousands of scientific citations, have earned these instruments a central space in many scientific faculties.

  • Variations in molecule concentration, external temperature, level of agitation, and time all impact the stability of biological molecules. Instabilities mainly result in denaturation and aggregation of the molecule, through which they can lose their biological function, elicit an immune response, and consequently limit their therapeutic viability. Factors affecting therapeutic efficacy and immunogenicity, therefore, need to be monitored throughout the development pipeline, especially at early stages, to de-risk the biological drug molecule and limit late-stage failures. The Zetasizer range provides high-quality, stability-indicating data for biological drug molecules in a short time frame, enabling this measurement to be implemented throughout the development pipeline.

  • Zetasizer systems are used to analyze particle size and zeta potential to improve the appearance and taste of foods, drinks and flavorings, and optimize dispersion and emulsion stability to extend product shelf life and improve product performance.

  • Zetasizer measurements of nanoparticle size distribution, dispersion properties, stability and propensity to aggregate are crucial to the design of new nanomaterials. The very large surface area of such materials may result in novel physical and chemical properties, such as increased catalytic activity, improved solubility or unexpected optical or toxicological behavior.

  • Paint, ink and coating formulations must be stable to keep them in an optimum state over time without change or aggregation. Particle size and zeta potential, measured by the Zetasizer instruments, play important roles in determining a product’s properties, such as dispersibility, color, strength, finish, durability and shelf life.

  • The correct particle size and zeta potential can help ensure the production of effective therapeutics, delivered safely. Zetasizer systems are used to characterize the stability and quality of dispersions, emulsions and creams, reducing formulation time and speeding new products to market.

Compliance made easy with OmniTrust

Ensure system access and records are secure, consistent, and easy to review for 21 CFR Part 11 with OmniTrust - our compliance solution for regulated environments.

Regulated environment

Key applications

  • For protein researchers, early access to characterization data can be a challenge, due to low sample volumes. This is easily overcome using the Zetasizer Lab with the capillary cell to confirm that samples meet quality requirements and that production and purification processes are optimized.

  • Monitoring viral concentration is important during development and production optimization. By using the Multi-Angle DLS (MADLS) based particle concentration measurement in the Zetasizer Ultra, both the size distribution and titer of the virus can be measured within a few minutes.

  • Photoluminescent C-dots are considered safer alternatives to quantum dots. Measuring fluorescent samples by DLS can be challenging due to additional photons emitted by the fluorophore. Available with NIBS on Zetasizer Pro, a filter removes this interference to provide accurate and reliable data.

  • The strength of ceramics is linked to particle size, and the Zetasizer is ideally placed to measure this. Al₂O₃ samples are often made of differently-sized particles which can easily be identified using MADLS. In this 0.1% w/v sample, the two particle size populations would not be distinguishable with a single angle DLS measurement.

  • Titanium dioxide use is wide-ranging. When used in paints or inks, agglomerate or aggregate formation can diminish product performance. The Zetasizer Pro Blue Label, used alongside the MPT‑3 Autotitrator, characterizes the impact of salt concentration on the stability of TiO₂ and identifies the most stable pH region.

  • Sizing of colloidal silica is a critical requirement. This is easily and reproducibly measured using the Zetasizer.

Proven in laboratories worldwide

Proven in laboratories worldwide through customer experience and supported by thousands of scientific publications and citations.

Unleash the full potential of your Malvern Panalytical solution

Malvern Panalytical instruments are built to last and good maintenance and care ensure continued peak performance for many years to come.

Support

Related resources

MyScientist: your own personal application specialist

Move beyond generic AI. Access expert guidance on sample preparation, method development, and result interpretation - powered by exclusive Malvern Panalytical knowledge and scientific expertise that isn’t available anywhere else.

MyScientist

Specification

Measurement principle Classical 90° Dynamic Light Scattering
Measurement angle 90°, 13° 1
Measurement range 0.3 nm - 15 μm 2
Minimum sample volume 3 μL
Concentration range
Minimum Sample Concentration:
Blue Label: 1 mg/mL 15 kDa Protein
Red Label: 0.3 mg/mL 15 kDa Protein
 
Maximum sample Concentration: 3
40% w/v

Accessories

Zetasizer's extensive range of enhancements and cell/cuvette options are designed to maximise your systems performance, flexibility and efficiency, with each component ensuring smooth operation, accurate results and easy adaptation to your analytical workflow.

Manuals

Title Version Date Download
{{ row.title }} {{ row.softwareVersion }} {{ row.date }} Download

Sorry, no manuals are available for this product

Software

Title Version Date Download
{{ row.title }} {{ row.softwareVersion }} {{ row.date }} Download

Sorry, no software downloads are available for this product

Publications

Ready to revolutionize your lab?

Ready to revolutionize your lab?

Adaptive Correlation, M3-PALS and constant current zeta mode, with easy to use software and data quality feedback. All incorporated into a compact, user-friendly instrument.

Request a quote