Comprehensive turnkey solutions for elemental analysis of all Rare Earth Elements (REEs). Download now

Download now

The Minerals edition of Zetium

The new element in minerals

The Minerals edition of the Zetium spectrometer is designed for materials analysis at all stages of the mining process. From exploration samples to mineral concentrates, ores to tailings, the Minerals edition delivers superior flexibility, analytical performance and stability in demanding mining environments.

Looking for more information?

To request a quote, more information or download a brochure select an option below.

Overview

The Minerals edition is pre-configured to cover a wide elemental range from oxygen (O) to americium (Am) at concentrations from ppm to 100 wt%.

The system is delivered with a new, faster sample changer, the latest version of our renowned SuperQ software (including our new Virtual Analyst), and your choice of application solutions, including:

  • WROXI for the analysis of oxides in geological samples
  • Certification of 20 in-house samples

Applications

Like all Zetium spectrometers, the Minerals edition delivers reliable analytical performance regardless of the application and excels at major, minor and trace element quantification in geological materials from exploration to tails in industries such as: 

  • Iron ore 
  • Base metals
  • Bauxite and alumina
  • Precious metals
  • Rare earth elements (REEs)
  • Raw materials
  • Phosphates
  • Coal

Customizations

The system can be customized to measure elements lighter than O. It can be further optimized to meet even the most demanding requirements with a choice of packages for improvements in speed, robustness, flexibility and sensitivity. 

The possibility to add our innovative ED core delivers unique advantages in mineral and mining applications, including:

  • reduction in analysis times of up to 50 % or improved precision in a given time
  • identification of unexpected elements in production
  • enhanced traceability with spectrum archiving

Features

Sensitivity and sample throughput

  • Unrivalled analytical sensitivity at unprecedented speeds with superior detectors and counting electronics
  • High-capacity sample bed with a high-speed sample changer, ideal for medium to high sample throughput
  • Ready for automated environments
  • Speed & throughput upgrade packages

Ready for tough environments

  • Rugged design with 3 levels of practical drift minimization technology
  • Outlier detection and process control with Statistical Process Control software - ideal for traceability and accreditation
  • Robustness & uptime upgrade packages

Application flexibility

  • WROXI for the analysis of 21 oxides in geological materials
  • Pro-Trace delivers unrivalled trace element analysis of up to 44 elements in geological materials, without the need to determine major element concentrations first
  • Sample certification of up to 25 of your own, in-house, standards by our ISO 17025-certified laboratory, so that you can use them as calibration standards or monitor sample

Advanced analytical software for advanced analytical hardware

The latest version of our renowned SuperQ software features a new, streamlined user interface, advanced matrix correction algorithms, such as variable alphas, integration of ED deconvolution and integrated intelligence with the Virtual Analyst.

Specification

Sample loading Fast sample changer and turret-style loading
X-ray tubes 2.4 kW SST R-mAX: Unique, drift-free, super-sharp SST R-mAX X-ray tubes feature new technology for improved robustness
Applications
WROXI or sample certification
WROXI application module, for the analysis of major and minor oxides in geological materials 
Certification of up to 25 of your own samples by our ISO 17025-certified laboratory, for use as in-house calibration or monitor samples
Options Performance upgrades

SumXcore
Up to 50 % reduction in measurement times 
Identification and flagging of unexpected elements in production control

Continuous loading
A second turret position allowing a second sample to be loaded and evacuated while the first is measured

Direct loading
A tool that allows loading of solid samples into pre-loaded sample cups in the turret positions, minimizing overhead times and improving repeatability

2.4 to 4 kW power upgrade
Same analytical results in a shorter time

Accessories

Manuals

Title Version Date Download
{{ row.pageTitle }} {{ row.softwareVersion }} {{ row.date }} Download

Sorry, no manuals are available for this product

Software

Title Version Date Download
{{ row.title }} {{ row.softwareVersion }} {{ row.date }} Download

Sorry, no software downloads are available for this product

Unleash the full potential of your Malvern Panalytical solution

[Technical support services cut corner engineer icon.jpg] Technical support services cut corner engineer icon.jpg

Unmatched uptime and performance


Malvern Panalytical instruments are built to last and good maintenance and care ensure continued peak performance for many years to come.

  • Service Agreements  build this into your schedule and budget, based on  preventive maintenance and remote support . Different levels include repair visits, response times and parts coverage as needed. OQ services, training and application consultancy can be added as well.
  • Smart Manager  goes even further:  Smart Manager  is a set of digital monitoring services combined with insight from experienced service professionals. Smart Manager is your trusted guardian for instrument health and utilization management, ensuring unrivaled accuracy, reliability, and efficiency in your analyses – on time, all the time.

[People in lab] shutterstock_1104131795.jpg
Service Agreements
Find out more about our service agreement options tailored for you
Learn more >>


[PN14321_Smart Manager Mastersizer Zetium graphic.jpg] PN14321_Smart Manager Mastersizer Zetium graphic.jpg
Smart Manager
Find out more about our instrument monitoring services
Learn more >>

[Training and expertise cut corner presenter icon.jpg] Training and expertise cut corner presenter icon.jpg

Advanced analysis and actionable insights


  • Basic User Training : Master the art of optimal Zetium usage and determine whether your measurements, sample preparation, and data are accurate and reliable – all while uncovering invaluable maintenance tips and tricks.  Find your online or offline classroom training course .
  • Customized Application Training : A training journey personalized to your application needs , covering aspects from sample taking and method development to data and results interpretation. Our application scientists share in-depth theory and best practices to make sure you’re getting the most out of your Zetium measurements and instruments.
  • Analytical and Consultancy Services : Our expert services place specialists and scientists at your disposal for method development, sample preparation, and certification. From oxides to sulfides, from trace to major elements, from particle sizing to molecular interaction – gain unparalleled analytical expertise.  Find out more .

[shutterstock_2189901805 cropped.jpg] shutterstock_2189901805 cropped.jpg
XRF testing services
Find out more about our custom XRF testing services
Learn more >>

[Product support cut corner cog icon.jpg] Product support cut corner cog icon.jpg

Easy start and streamlined routine operations


  • Setting up for success: Our Zetium onboarding starts with our expert support engineers on-site. A comprehensive warranty and a starter training program are complimentary, so you can get straight to your important analyses.
  • Software and Manuals:  Easily find  manuals and our latest software versions  online to benefit from new features and to stay up to date.
  • Webinars and App Notes:  Access a  comprehensive catalog of resources , such as recorded webinars, white papers, and app notes to support your analytical journey. 
  • Parts and Consumables -  MyStore :  Our online store  makes access to your parts, consumables, accessories, and software convenient and efficient. Check availability and pricing, self-service quotes and order on card or account, 24/7. 
  • Support Portal:  Our professional service team is ready to assist you – fast-track your service request on  Malvern Panalytical My Customer Support Portal  or view your system details and service history at a glance.
[Service team and contact cut corner agent icon.jpg] Service team and contact cut corner agent icon.jpg

Want to speak to a service expert or find the services that are just right for you?


Reach out to our experts and evaluate your services needs and business risks by answering a few questions around the usage of your Malvern Panalytical instrument.


Contact Service Team

*Please note that the exact details of our services and their availability are determined by a variety of customer-specific factors, such as product type, product configuration, or location.

Publications

Advance your analysis.

Advance your analysis.

Fast, reliable materials analysis at all stages of the mining process - even in demanding mining environments.

Contact sales Request a quote Request a demo