Microfluidic chip price

Microfluidic chip price

How much do microfluidic chips cost? 

There are a range of microfluidic chip prices, depending on the type of chip and its features.

Reusability

One of the biggest factors determining the cost of a microfluidic chip – and ultimately, its cost of use – is reusability. Some devices – such as COVID-19 self-tests – use single-use chips, which cannot be reused once the microfluidic channels have been filled with a sample. Other chips, such as those used in optical biosensors, allow you to measure more than one sample per channel. This typically makes both device and microfluidic chip cost more.

Our no-clog KYMAchips can often be used repeatedly. How many times depends on the experimental set-up and surface chemistry, including ligand stability, sample composition, buffers, and surface chemistry. For instance, if your ligand is not very stable or if your sample contains other molecules that interact with the surface, you may not be able to test a high number of samples or take repeat measurements. In addition, it’s possible to regenerate and recapture ligand proteins multiple times with Ni-NTA and Protein A/G chips. 

Chemical resistance and extra coatings

Microfluidic chip prices also depend on the material from which the chips are made, and whether there’s a matrix coating the surface. Some experiments require buffers that might otherwise erode the chip, which means the chip has to be made of materials with high chemical resistance. And chips for optical biosensors can require a coating, which then needs to be compatible with the ligand to allow immobilization for measurements of binding kinetics and affinity.

適切なマイクロ流体チップの選択

マイクロ流体チップの各タイプは、異なるターゲット、タグ、ターゲットと検体の比率、およびマトリックスに対応しています。

当社のWAVEchipsと互換性のあるものの概要については、以下の表をご覧ください。

アプリケーションのニーズに適したマイクロ流体チップを選択していることを確認するには、当社までお問い合わせください。

ターゲット別

タンパク質抗体膜タンパク質負電荷リガンドリポソーム、小胞、自己組織化有機微粒子VLPs/大きい粒子
4PCH WAVEchip✔✔✔
4PCH-STA WAVEchip✔✔✔
4PCH-NTA WAVEchip✔✔✔
4PCP WAVEchip✔✔✔✔✔
4PCP-STA WAVEchip✔✔✔✔✔
4PCP-NTA WAVEchip✔✔✔✔✔
4PCP-PAG WAVEchip✔✔
4PCP-LIP WAVEchip✔✔✔✔✔
4PCZ WAVEchip✔✔✔✔
4DXH-STA WAVEchip✔✔✔

タグ別

アミン共有結合HisストレプトアビジンIgGFCがタグ付けされました脂質
4PCH WAVEchip✔
4PCH-STA WAVEchip✔
4PCH-NTA WAVEchip✔
4PCP WAVEchip✔
4PCP-STA WAVEchip✔
4PCP-NTA WAVEchip✔
4PCP-PAG WAVEchip✔✔
4PCP-LIP WAVEchip✔
4PCZ WAVEchip✔
4DXH-STA WAVEchip✔

ターゲット別:検体MW率

99:1未満100:1~350:1350:1より大きい
4PCH WAVEchip✔✔✔
4PCH-STA WAVEchip✔✔✔
4PCH-NTA WAVEchip✔✔✔
4PCP WAVEchip✔
4PCP-STA WAVEchip✔
4PCP-NTA WAVEchip✔
4PCP-PAG WAVEchip✔
4PCP-LIP WAVEchip✔
4PCZ WAVEchip✔✔✔
4DXH-STA WAVEchip✔✔✔

マトリックス別

バッファ洗浄剤を使用したバッファ(高濃度)粗反応混合物血清および血漿
4PCH WAVEchip✔✔✔
4PCH-STA WAVEchip✔✔✔
4PCH-NTA WAVEchip✔✔✔
4PCP WAVEchip✔✔✔
4PCP-STA WAVEchip✔✔✔
4PCP-NTA WAVEchip✔✔✔
4PCP-PAG WAVEchip✔✔✔
4PCP-LIP WAVEchip✔✔
4PCZ WAVEchip✔✔
4DXH-STA WAVEchip✔✔✔