Types of Standard Samples and Consumable Package for Particle Size and Zeta Potential

Types of Standard Samples and Consumable Package for Particle Size and Zeta Potential
Are the particle size and zeta potential values measured accurate?
Are the particle size and zeta potential values measured by the Mastersizer particle size analyzer and Zetasizer nano particle and zeta potential analyzers you are currently using accurate?

You can now directly verify whether your device operates accurately within its defined specifications.

Malvern provides standard samples for particle size measurement and zeta potential verification.

For further inquiries, please contact support.korea@malvern.com or call 1577-8378.

 
Standard Samples and Software Update for Particle Size Analyzer

Standard Sample for ISO 13320-1 Compliance
Standard Sample for Small Volume Dispersion Devices (QAS 3001B)
Standard samples for verifying particle size in Mastersizer series’ Hydro2000S, 2000SM, MV
– Consists of 10 disposable samples of 0.4g per box

Request Quote for Particle Size Analyzer Standard Sample>

​

Standard Samples for Wet and Dry Dispersion Devices (QAS 3002)
–
Standards for verifying particle size in Mastersizer series’ Wet Hydro2000MU, 2000G, LV, EV, Aero S, Scirocco 2000
– Consists of 10 disposable samples of 2.5g per box

Particle Size Analyzer Equipment Software Update
– Software version 3.0 update is now available for free download on the website. The biggest advantage of the latest version is the real-time verification of measurement data based on refractive index and absorbance selection.
 

Download Particle Size Analyzer Software>

Standard Samples and Software Update for Nano Particle Size and Zeta Potential

Standard Sample for Nano Particle Size Verification
60 Nano Particle Size Standard Sample (LTX3060A)
– Nano particle size verification sample
– Nominal Diameter / Bottle Size=60nm /15ml
200 Nano Particle Size Standard Sample (LTX3200A)
– Nano particle size verification sample
– Nominal Diameter / Bottle Size=200nm /15ml

Standard Sample for Zeta Potential Verification
Zeta Potential Standard Sample (DTS 1235)
– Standard sample for verification with Zetasizer Nano series
– Consists of 10 syringes per box
– Can perform installation test with Polystyrene latex
– Complies with National Institute of Standards and Technology (NIST) standards

Nano Particle Size and Zeta Potential Standard Sample

Request Quote> 

​

​

Nano Particle Size and Zeta Potential Analyzer Software Update
Guide

– Zetasizer Nano particle size and zeta potential analyzer software v7.10 is available for free download on the website. The latest software version includes an Auto Sampler feature.
 

Download Nano Particle Size Zeta Potential Analyzer
Software>


Consumable Package Guide for Effective Nano Particle Size and Zeta Potential Measurement
Zstasizer Nano Series Zetasizer Nano Series Consumable Kit
Composition:
– Cell and stopper kit, 100 Polystyrene cuvettes (DTS0012)
– 60nm/15ml Polystyrene latex standard, 1 syringe (LTX3060A)
– Zeta Potential transfer standard, 1 syringe (DTS1233)
– 12mm square cell with cap (PCS8501)
Compatible Products:
Zetasizer Nano S, NanoZS)