Particle Testing Authority Price List

Introduction

Select the appropriate analyses from the Price List options below to use with your Sample Submission Form, and find out more about our timeframes, discounts and other information for the Particle Testing Authority service.

Particle Size and Particle Shape

Laser Light Scattering – Mie and Fraunhofer Theories
PSA-03 (Formerly 520-50)Dry Dispersion methods using a Malvern Mastersizer (ISO 13320)$385
PSA-04 (Formerly 520-51)Wet Dispersion methods using a Malvern Mastersizer (ISO 13320$385
X – Ray Sedimentation – Stokes’ Law
PSA-05 (Formerly 510-00)Aqueous and non-aqueous based dispersion inorganic materials only (ISO 13317-3) (Requires Density- 01 prior to analysis if skeletal density is not provided$395
Nano Particle Size
Physi-23 (Formerly 005-70)Average particle size calculated from BET surface area$315
PSA-10 (Formerly 005-71)Dynamic light scattering/ photon correlation spectroscopy (ISO 22412)$375
Zeta Potential
PSA-16 (Formerly 120 -00)Zeta potential (ISO 13099-2)$395
PSA-17 (Formerly 120-01)ISO-electric point determination and pH titration$795
Microscopy
Morph-01Static image analysis of particle size and shape$650
SEM-01 (Formerly 010 – 40)SEM Imaging (Outsourced)Call
SEM-02 (Formerly 010 – 41)SEM Imaging with EDS (Outsourced)Call
SEM-03 (Formerly 010 – 50)Contamination or particle identification (outsourced)Call
SEM-04 (Formerly 005-81)Particle shape using an automated microscopy technique (Outsourced)Call
Other Particle Size Techniques
PSA-11 (Formerly 005-73)Particulate count and concentration using the light obscuration technique (USP method and)$395
PSA-12 (Formerly 005-74)Sub-Sieve AutoSizer (ASTM B330-07 , ASTM C721, 150-10070) (Requires density prior to analysis) Air permeability diameter$385
PSA-14 (Formerly 010-16)Dry or wet sieving available/ Ro-Tap apparatus$275
PSA-15 (Formerly 010-78)Particle size of material on filters$400
SEM-03 (Formerly 010-SO)Particle size using automated microscopy techniquesCall
Mayer – Stowe
PSA-18 (Formerly 942 -09)Particle size calculation from Mercury intrusion analysisCall
BET or Langmuir Surface Area; T-Plot area
Physi-01 (Formerly 005-01)Multipoint surface area using nitrogen gas (ISO 9277)$335
Physi-02 (Formerly 005-02)Multipoint surface area using krypton gas (ISO 9277)$390
Physi-04 (Formerly 005-10)Multipoint surface area and STSA using nitrogen gas (ASTM D6556)$350
Physi-05Multipoint surface area using Argon$390

Pore Volume Distribution / Pore Size Distribution

Pore Size by Gas Adsorption
Pore size samples may include the following reports as appropriate: BET or Langmuir surface area, BJH mesopore analysis, DFT pore size calculations, single-point total pore volume, and t-Plot micropore volume (ISO 15901-02).
Physi-10 (Formerly 005-50)40-point nitrogen adsorption isotherm (20 A to 3000 A)$530
Physi-12 (Formerly 005-08)40-pt Nitrogen adsorption and 40-pt desorption isotherm (20 A to 3000 A)$695
Micropore Pore Size Distribution
Reports may include H-K, Dubinin, and/or DFT methods for micropore analysis (ISO 15901-3)
Physi-11Micropore isotherm for pore sizes of 5-20 Å$625
Physi-13 (Formerly 201-03)High-resolution micropore analysis plus mesopore isotherm (4 A to 3000 A)$1095
Surface Energy Analysis
Physi-14DFT surface energy distribution with nitrogenCall
Physi-15DFT surface energy distribution with dft surface energy distribution with argonCall
Pore Size by Mercury Intrusion
Report will include calculations of bulk density, skeletal density, porosity, average pore diameters, median pore diameters, and total intrusion volume. Additional summary reports such as tortuo slty, fractal dimension, permeability, and compressibility are available upon request for an additional fee (ISO 15901-01).
MIP-01 (Formerly 942-03)Mercury intrusion analysis (pore size range 360 to 0.003 μm)$515
MIP-02 (Formerly 942 – 04)Mercury Intrusion and extrusion analysis (pore size range 360 to 0.003 μm)$575
MIP-03 (Formerly 942-10)High-resolution macropore analysis (pore size range 900 to 4 μm)$480
MIP-04 (Formerly 942 -11)High-resolution macropore plus a complete intrusion and extrusion analysis$720
MIP-05Reverberi method for pore throat and pore cavityCall
MIP-06High-resolution intrusion (pore size range 900 to 0.003 μm)$645
MIP-10 (Formerly 942-05)Advanced Hg calculations$118
Density
Density-01 (Formerly 133 – 00)Skeletal density (Helium or Nitrogen pycnometry) ISO 12154, USP$185
Density-02 (Formerly 133 – 01)Skeletal density at specific temperature$220
Density-03 (Formerly 133 – 02)Open cell content of rigid cellular plastic, foam density (ASTM 06226)$300
Density-04 (Formerly 136 – 00)Envelope density of solid, non-powder samples using the GeoPyc”‘ 1360$220
Density-05 (Formerly 136 – 01)T.A.P.™ (Transverse Axial Pressure) density using the GeoPyc® 1360$266
Density-07 (Formerly 942 – 07)Mercury bulk density$390
Density-08 (Formerly 010 – 70)Bulk and Tap density USP$250
Density-09 (Formerly 010 – 77)Bulk density only$178
Special Vapor Sorption Services
Physi-20 (Formerly 005 – 60)Special CO2 isotherms at O °C$750
Physi-21 (Formerly 005 – 60)Adsorption isotherms at user defined conditions (specialty gases)$1240
Physi-22 (Formerly 005 – 61)High-pressure isotherms using hydrogen, nitrogen, oxygen, methane, or other gases$1275
Vapor-01 (Formerly 005 – 63)Vapor isotherms – Dynamic vapor sorption (DVS) gravimetric analysis$890
Vapor-02 (Formerly 005 – 64)Vapor isotherms using volumetric technique (ASAP 2020 or 3Flex)$890
Chemisorption
Chemi-01 (Formerly 201 -10)Volumetric chemisorption analysis (specify analytical method)$999
Chemi-02 (Formerly 291- 23)Dynamic or pulse chemisorption analysis (specify analytical method)$999
Chemi-03 (Formerly 291- 03)Pulse chemisorption using liquid vapors (specify analytical method)$1101
Temperature-Programmed Studies
Chemi-04 (Formerly 291- 01)Temperature-Programmed Reduction (TPR)$849
Chemi-05 (Formerly 291-10)Temperature-Programmed Desorption (TPD)$849
Chemi-06 (Formerly 291- 02)Temperature-Programmed Oxidation (TPO)$849
Chemi-07 (Formerly 291- 06)Mass spectrometry analysis (must be combined with temperature program study)$380
Chemi-09Temperature-Programmed surface reactionCall

Other Chemisorption Experiments

Other Chemisorption Experiments
Chemi-21 (Formerly 201- SO)Isosteric heat of adsorptionCall
Chemi-22 (Formerly 291- 20)Heat of desorption, first order kineticsCall
Powder Rheology
Powder-01Complete set of powder testing using the FT4, including dynamic flow properties, bulk powder properties and shear properties. A summary report will be provided.$1595
Powder-02Dynamic flow properties Include basic flowability , aeration test ing and consolidation test ing along with summary report.$750
Powder-03Bulk powder property testing includes compressibility and permeability testing along with a summary report$650
Powder-04Shear property testing includes shear cell testing and wall friction testing along with a summary report.$650
Powder-05Individual powder property testing , choose from flowability , aeration, consolidation, compressibility, permeability, shear and wall friction testing. Price Is per test and per sample. No summary report available.$315
Powder-09Angle of Repose$175
Capillary Flow Porometry
Filter-01Scanning porometry of pore sizes down to 30 nm using a POROLUXTM 100/l OONW; 500$310
Scientific Services
PTA-01 (Formerly 010 – 00)Non-standard laboratory analysisCall
PTA-02 (Formerly 010-10)PTA-02 (Formerly 010-10)Call
PTA-03 (Formerly 010-11)Method validation servicesCall
PTA-04Method verification or method transferCall
PTA-05 (Formerly 010- 06)Consulting services and detailed results interpretationCall
Other Services
PTA-06 (Formerly 010-80)Special sample preparation or storage (glove box or freezer)$175
PTA-10 ( Formerly 005 – 87)Expert testimonyCall
PTA-13 (Formerly 010-01)Certificate of analysis$110
PTA-40 (Formerly 005- 85)Dynamic void volume – DVVA (ASTM D7854)$350
MIP-11 (Formerly 950-50)Volume calibration of AutoPore Mercury penetrometers$425
PTA-104Percent heat loss meaning (moisture)$150
PTA-105pH determination of solution$80

Sample Turnaround Times

Turnaround times are typical for most projects, but exclusions apply.

Normal (Typically within 7 business days)List Price
Priority (Typically 2 to 4 business days)List Price + 50% surcharge
Rush (Next sample analyzed)List Price+ 200% surcharge

Volume Discount Schedule

VolumeDiscount
6-10 samples5% discount
11-20 samples10% discount
21- 40 samples15% discount
More than 40 samples20% discount

Additional Information

There is a 10% surcharge for all cGMP and GLP samples or projects and A2LA accredited reports. Not all tests listed are included In our A2LA Scope of Accreditation. Please consult A2LA Certificate 3636 ,01 for a list of accredited tests.

All orders are subject to Particle Testing Authority Terms and Conditions (US) or Terms and Conditions (EU).

Terms

Net 30 days as standard.

For 45 days add 2%, for 60 days add 4% to the final negotiated price.

We accept Credit card and purchase order.

Sample Disposal and Returns

There is a flat carrier fee of $80 USD for domestic sample returns. Domestic hazard material flat fee is $280 USD. International sample return flat fee is $160 USD. International hazard material flat fee is $495 USD. Samples can be returned using a customer carrier account, or at the customer’s expense, provided correct shipping and payment information is received. FedEx service is used for all international returns.

All hazardous materials will be returned to customers. SDS are required for all samples.

Sample and Data Retention

Unless otherwise requested, samples will be retained for a minimum of 3 months. 

Sample results will be maintained for a minimum of 5 years. 

All samples and related customer information is kept confidential.