Epsilon 3X in automation

Flexible and safe automation for process control

Historically, the automation of X-ray fluorescence (XRF) instruments has been limited to high-power wavelength dispersive (WD)XRF systems. However, more and more benchtop energy dispersive (ED)XRF spectrometers are sold into production control as cost-effective solutions because of improved performance. Recent advances in Epsilon 3X (ED)XRF spectrometers make them an attractive alternative in automated environments.

The Epsilon 3X automation option is a simple and flexible solution interfacing your existing Epsilon 3 or new Epsilon 3X analyzer to any sample preparation equipment. The flexible sample introduction system is specifically designed to handle a variety of prepared samples coming from a belt, a robot or even from a manual input slide.

Solicite um orçamento Solicite uma demonstração Fale com Vendas

Features

Easy to integrate Epsilon 3X

New and existing Epsilon 3X spectrometers (with standard lid only) are easily integrated in the field without any modification necessary to the instrument. You will not void any guarantees or legal conformities by putting your Epsilon 3 unit inside the automation cabinet. 

Complete safety 

Prepared samples are picked up from a belt and transferred inside the Epsilon 3X instrument in complete safety. The instrument is enclosed in a sealed cabinet for safe operation and protection against dust, making it extremely robust. The interlocked cabinet door protects the operator from moving components during operation. 

Flexible sample introduction 

Prepared samples can be introduced to the Epsilon 3 instrument in four different ways: 

  • sample on conveyer belt with surface down
  • sample on conveyer belt with surface up (using sample inverter mechanism)
  • via robotic arm (located outside the cabinet)
  • via manual sample slide (through-wall operation).

Support

Serviços

Soluções para maximizar o retorno do seu investimento

Para garantir que o instrumento permaneça em condição máxima e funcione no nível mais elevado, a Malvern Panalytical oferece uma grande variedade de serviços. Nosso conhecimento e nossos serviços de suporte garantem o funcionamento ideal do instrumento.

Suporte

Manutenção para sempre

  • Suporte remoto e por telefone
  • Manutenção preventiva e verificações
  • Contrato de atendimento flexível ao cliente
  • Certificados de desempenho
  • Upgrades de hardware e software
  • Suporte local e global

Conhecimento

Agregando valor aos seus processos

  • Desenvolvimento/otimização na preparação da amostra
  • Metodologias de análise 
  • Soluções completas para XRD 
  • Operações através de IQ/OQ/PQ, garantia de qualidade (GLP, ISO17025), estudos interlaboratoriais
  • Automação de processos do laboratório
  • Serviços de consultoria

Treinamento e formação

  • Treinamento presencial ou em nossos centros de competência
  • Ampla variedade de cursos básicos e avançados sobre produtos, aplicativos e softwares

Serviços de análise e materiais de calibração

  • Serviços e análises especializadas (XRF)
  • Análise de óxidos e traços
  • Materiais de calibração personalizados