Ministry of Health, Labour and Welfare ‘Guidelines for the Development of Liposome Preparations (March 28, 2016)’ and Physical Property Evaluation

The guidelines state in ‘3.2.2 Analysis of Preparation Characteristics’ that various physical property evaluations are required as follows.
① “Particle Size Distribution: Display with quantitative indicators along with mean or median values. Testing methods include dynamic light scattering measurement and laser diffraction measurement. It is important to clearly state the distribution display used for analysis (number-based distribution, volume-based distribution, etc.).”
② “Surface Charge (Zeta Potential): Since surface charge cannot be directly measured, it is generally evaluated and considered as zeta potential. The dominant testing method is electrophoretic light scattering (laser Doppler method).”
③ “Thermodynamic Characteristics of Liposome Membrane: Evaluated by differential scanning calorimetry and fluorescence spectral characteristics of lipid membrane-inserting fluorescent probes depending on temperature. Thermodynamic characteristics like exothermic or endothermic profiles are useful indicators for the fluidity and homogeneity of lipid bilayers.”
This page introduces the relationship between necessary parameters for evaluation and corresponding analytical equipment.
① Particle size distribution (particle size measurement)
21CFR Part11 fully compliant
We also offer consultations for the full automation of analytical operations.
High-concentration sample compatible units are also available.
For detailed inquiries and demo measurement requests, please click here.
② Measurement of particle size distribution, zeta potential measurement, and particle concentration calculation
Improved reproducibility and stability with the addition of new measurement algorithms
Multi-angle dynamic light scattering (MADLS®) enhances resolution and adds particle concentration measurement function
3 μL disposable cells are now available
For detailed inquiries and demo measurement requests, please click here.
 New  Next-generation equipment of the Zetasizer Nano series
Zetasizer Advanced series has arrived 
③ Particle size distribution measurement and particle concentration measurement
Visualizes the presence of nanoparticles
Calculates particle size distribution based on numbers
Concentration calculation function
For detailed inquiries and demo measurement requests, please click here.
④Evaluation of Thermodynamic Characteristics
No labeling required
Ultra-low volume, high-sensitivity detection
Academic pricing available!

For the PEAQ-DSC video, click here
For detailed inquiries and demo measurement requests, click here.

!function(d,s,id){var js,fjs=d.getElementsByTagName(s)[0],p=/^http:/.test(d.location)?’http’:’https’;if(!d.getElementById(id)){js=d.createElement(s);js.id=id;js.src=p+’://platform.twitter.com/widgets.js’;fjs.parentNode.insertBefore(js,fjs);}}(document, ‘script’, ‘twitter-wjs’);
lang: ja_JP

Recommended articles

For questions or inquiries, click here≫