The Malvern Panalytical NanoSight LM10 is a highly flexible and robust instrument that can be upgraded at any time to fit the changing needs of both routine testing and research laboratories.

  • Visual validation of results gives extra confidence.
  • Minimal sample preparation.
  • Choice of standard or high sensitivity camera.
  • Choice of sample chamber with or without temperature control.
  • Choice of interchangeable laser blocks and wavelengths.

The Malvern Panalytical NanoSight LM10 uses the technology of Nanoparticle Tracking Analysis (NTA). This unique technology utilizes the properties of both light scattering and Brownian motion in order to obtain the size distribution and concentration measurement of particles in liquid suspension. A laser beam is passed through the sample chamber, and the particles in suspension in the path of this beam scatter light in such a manner that they can easily be visualized via a 20x magnification microscope onto which is mounted a camera. The camera operates at 30 frames per second (fps), capturing a video file of the particles moving under Brownian motion. The software tracks many particles individually and using the Stokes-Einstein equation calculates their hydrodynamic diameters.

General

Wavelength:
405nm (violet), 488nm (blue), 532nm (green) or 642nm (red).
Temperature control range:
Optional (5°C below ambient to 50°C).
Stage:
Manual stage.
Focus:
Manual focus.
Camera:
CCD or sCMOS.
Fluorescence:
Manual push/pull filter holder with 2 filters.
Dimensions (W, D, H):
420mm x 200mm x 260mm.
Particle size:

10nm to 2000nm*

*Sample and system configuration dependent

Concentration range:
106 to 109 particles per mL.
Power:
100V - 240V

NanoSight LM10

NanoSight syringe pump

Image

The Malvern Panalytical NanoSight syringe pump is available for all Malvern Panalytical NanoSight systems, enabling users to perform sample analysis at a constant flow rate.

More information

Protect your investment and ensure optimized performance at all times with Malvern Panalytical's service plans.

When you purchase a Malvern Panalytical product we understand that this is just the first stage of a working relationship that will last for the lifetime of the instrument. Depending on your needs, Malvern Panalytical will provide the support for your business.

Help Desk

Training

Software downloads

Malvern Panalytical's service options- choose the right plan for you:

Malvern Panalytical Platinum Plan

For laboratories where maximizing instrument up-time is critical to its daily performance. Our highest level of response and the 'all inclusive' price plan takes care of those unexpected repair bills should the unfortunate occur.

Malvern Panalytical Gold Plan

Enhance your laboratory productivity by maintaining instrument efficiency. Still receive that priority response, combined with specialist technical and software support, we'll keep your instrument performance on track to deliver.

Malvern Panalytical Bronze Visit

For laboratories looking to optimize instrument performance, regular preventative maintenance is essential.

Platinum PlanGold PlanBronze Visit
Annual PM/PV Test
yes
yes
no
Telephone / Email Support
yes
yes
no
Priority Response
yes
yes
no
Emergency Breakdown visits*
yes
yes
no
Parts Included
yes
no
no
Technical & Software Support
yes
yes
yes
IQ/OQ (Pharma)***
yes
yes
yes

*including labour & travel costs***available at an additional cost