Using Isothermal Titration Calorimetry (ITC) and Grating-Coupled Interferometry (GCI) in Fragment-Based Drug Discovery
Fragment-based drug discovery (FBDD) is a powerful approach in modern drug development. It provides a way to identify promising drug candidates by starting small—screening molecular fragments with low molecular weights that bind weakly but specifically to biological targets.
But here’s the challenge: these weak interactions can be notoriously difficult to detect, let alone characterize.
Two such techniques — Grating Coupled Interferometry (GCI) and Isothermal Titration Calorimetry (ITC) — have proven invaluable in overcoming the challenges of fragment detection, binding validation, and thermodynamic profiling.

In this blog, we’ll explore how GCI and ITC complement each other and why integrating these technologies can transform your FBDD workflow.
The Challenge of Detecting Weak Fragment Interactions

Unlike small molecules that might have nanomolar affinities, fragments often bind in the micromolar to millimolar range. Fragment-based screening relies on detecting weak interactions between fragments and biological targets, typically with dissociation constants (KD) in the high micromolar to millimolar range. This requires analytical techniques that offer:
- High sensitivity to detect low-affinity interactions.
- Quantitative binding analysis to prioritize hits.
- Structural and thermodynamic insights to guide optimization.
GCI and ITC fulfil these criteria while offering complementary strengths.
Grating Coupled Interferometry (GCI): Precision Binding Kinetics

Grating Coupled Interferometry (GCI) might sound like a mouthful, but it is an advanced optical technique that provides real-time, label-free detection of molecular interactions. Unlike traditional surface plasmon resonance (SPR), GCI uses waveguide-based interferometry, making detection robust enough to handle the noise that comes with low-affinity fragments.
How GCI Supports FBDD:
- High Sensitivity for Low-Affinity Fragments: GCI excels in detecting weak-binding fragments that might go unnoticed with other methods.
- Detailed Kinetic Analysis: GCI measures association (kon) and dissociation (koff) rates, enabling the determination of binding kinetics (ka, kd) and affinities (KD).
- High-Throughput Screening: With its capacity to analyze multiple fragments simultaneously, GCI accelerates the identification of initial hits.
- Minimal Sample Consumption: GCI requires small amounts of fragment and target, conserving precious resources.
By identifying fragments with desirable binding kinetics, GCI provides an essential first filter in the FBDD workflow.
Isothermal Titration Calorimetry (ITC): Thermodynamics Unveiled

While GCI is excellent for assessing binding kinetics, ITC adds a critical dimension by characterizing the thermodynamics of fragment binding. ITC measures the heat released or absorbed during binding events, providing a complete thermodynamic profile, including enthalpy (ΔH), entropy (ΔS), and binding stoichiometry.
How ITC Adds Value to FBDD:
- Binding Validation: ITC confirms binding events detected by GCI, ensuring robust hit identification.
- Thermodynamic Insights: By understanding the enthalpic and entropic contributions to binding, researchers can prioritize fragments with optimal properties, and whether drug binding is enthalpy-driven (heat released) or entropy-driven (flexibility gained).
- Non-Specific Interaction Detection: ITC can differentiate between specific and non-specific binding events, further refining hit selection.
- Quantitative Affinity Measurement: ITC provides absolute binding constants (R + L ⇌ RL), complementing GCI’s kinetic data.
With ITC, researchers gain a deeper understanding of how fragments interact with their targets, which is essential for rational drug design.
The Synergetic dance of GCI and ITC in FBDD
Individually, GCI and ITC are powerful tools, but their combined use offers unparalleled insights into fragment binding. Here’s how they work together:
- Screening and Ranking: Use GCI to rapidly screen fragments and prioritize hits based on binding kinetics.
- Validation and Thermodynamic Profiling: Employ ITC to confirm binding events and characterize the thermodynamics of prioritized hits.
- Structure-Based Optimization: Combine kinetic and thermodynamic data to guide fragment optimization, ensuring the development of high-affinity, drug-like molecules.

The complementary nature of these techniques ensures that no valuable fragment is overlooked, and all critical binding characteristics are fully explored.
Real-World Impact of GCI and ITC Integration
Several pharmaceutical and biotech companies are already leveraging GCI and ITC in their FBDD programs with remarkable success. For example:
- Discovery of Allosteric Modulators: GCI identified weak allosteric fragment binders, while ITC provided the thermodynamic insights necessary for optimization.
- Efficient Fragment-to-Lead Transition: GCI’s kinetic analysis guided rapid fragment selection, and ITC’s thermodynamic data refined lead optimization, reducing time to clinical candidate.
By integrating these tools, teams can confidently progress from fragment hits to optimized leads with improved efficiency and accuracy.
Conclusion: A Winning Combination for FBDD
Fragment-based drug discovery demands cutting-edge tools that deliver high sensitivity, robust validation, and detailed binding insights. Grating Coupled Interferometry (GCI) and Isothermal Titration Calorimetry (ITC) exceed these requirements, providing complementary data that streamline the FBDD workflow.
By incorporating GCI and ITC into your analytical arsenal, you can unlock the full potential of fragment-based screening, accelerating the discovery of innovative therapies. If you’re ready to elevate your FBDD program, it’s time to explore the synergy of these transformative technologies.
Interested in learning more? Contact our team to discuss how GCI and ITC can revolutionize your drug discovery efforts.